background image

The Armcor Air Solutions Warranty Policy should be read in conjunction 

with the Terms and Conditions of Sale. These are available on our website 

armcor.com.au

Warranty

What The Warranty Policy Covers

The standard Armcor warranty policy is a parts only 

warranty for a 12 month period. If any defect in your 

Armcor equipment is caused by 

FAULTY MATERIALS

 

within the warranty period, starting from the date of 

original purchase it will be rectified or replaced without 

cost.
Additional labour warranty is available and must be 

purchased at the time of ordering in accordance with 

the warranty policy.

What The Warranty Policy Does 

Not Cover

• 

Consequential damage.

• 

Failure to start due to voltage conditions, blown fuses 

or other damage cause by inadequate or interrupted 

electricity supply.

• 

Damage caused by accident, misapplication, abuse, 

alteration, tampering or servicing by anyone other 

than an authorized person.

• 

Damage resulting from incorrect installation, 

commissioning or use other than in accordance with 

the installation and operating instructions issued by 

Armcor Air Solutions.

• 

Damaged caused by using equipment being located in 

a corrosive atmosphere or by filter neglect.

• 

Replacement of any worn drive belts if applicable.

• 

Costs incurred for regular maintenance services.

• 

The original service call costs in identifying a 

warranty claim.

• 

Freight and travel changes for work performed or 

parts supplied outside of all capital cities in Australia.

• 

Field wiring, refrigerant pipe run between units, the 

condensation drainpipe or other accessories.

• 

Any warranty work performed by Armcor Air 

Solutions outside of Melbourne metro area will 

require the installing contractor to provide free of 

charge: Oxy/Acetylene Equipment, Dry Nitrogen, 

Vacuum Pump, Refrigerant Gas, Reclaim Bottles, 

Recovery Unit, and any other associated refrigerant 

tools.

The Warranty Will Not Apply If;

• 

Any appliance plate is altered or removed.

• 

Armcor Air Solutions has not be notified within 48 

hours of any fault occurring which may require 

warranty work.

• 

Any unauthorized modification has been made to the 

equipment or any part has be substituted or replaced 

with non-original items.

• 

Regular service has not been carried out by an 

appropriate.Armcor approved, licenced installer.

• 

The unit is used other than for the heating and 

cooling of air for human comfort – unless approved 

by Armcor Air Solutions.

• 

The system is installed in a mobile application (eg. 

caravan, boat, crane).

How to Make a Warranty Claim

Complete a warranty form available on our website 

armcor.com.au

 and return the Armcor Warranty 

Request Form to: 

[email protected]

Contact us direct by phone on 1800 244 556 or email 

[email protected]

10               XEM – External Mount Unit Installation and Operation Manual 2021

Summary of Contents for XEM Series

Page 1: ...Installation and Operation Manual XEM External Mount Unit XEM400 XEM9000 M ADE A U STRALI A N Manufactured byArmcor M ADE A U STRALI A N Manufactured byArmcor...

Page 2: ...ilters Electrical Requirements Mains Power Supply and Fusing Standard Equipment Layout 8 General Maintenance 9 General Monthly Maintenance Schedules Guide to How Frequency According to Usage is Establ...

Page 3: ...transfer it to the incoming fresh air resulting in significant energy savings Both enthalpy and sensible heat exchange media are available Every proposed installation must be subject to an engineered...

Page 4: ...t recovery and or air handling equipment Installing and servicing equipment can be hazardous due to electrical and mechanical components When working on equipment observe precautions in all literature...

Page 5: ...recommend waffle pad to be used under the base frame and flexible couplings be fitted to the supply and return ducts to reduce any vibration transfer Fresh Air Inlet and Exhaust Air Outlet The locati...

Page 6: ...re to safety codes and guidelines Wear safety goggles work gloves work boots and protective clothing All external units are provided with substantial lifting lugs on each corner at the base frame NOTE...

Page 7: ...commissioning Where a Heat Exchanger is incorporated in the equipment warranty is void if filters are not fitted IMPORTANT NEVER OPERATE A UNIT WITHOUT FILTERS FITTED TO THE RETURN FRESH AIR INTAKES E...

Page 8: ...the unit Return Air Air that is drawn from conditioned area Exhaust Air Ducted to outside the building or into the roof space if adequate ventilation is available Fresh Air Use a fresh air cowl or gr...

Page 9: ...ensate drain if applicable for free drainage Guide to How Frequency According to Usage is Established Disposable Corrugated Filters Ordinary disposable corrugated filters should last approximately one...

Page 10: ...vices The original service call costs in identifying a warranty claim Freight and travel changes for work performed or parts supplied outside of all capital cities in Australia Field wiring refrigeran...

Page 11: ...y voltage is available on all phases Check overload settings are correct if applicable Filters Check that both the fresh air and return air have adequate filters before starting unit Starting Unit Che...

Page 12: ...s Estimate of Fresh Air Make Up or L s Electrical Supply Voltage Supply Fan Motor Amps Exhaust Fan Motor Amps Total Unit Amp Thermostat Settings C Thermostat Operating Correctly Y N Contactors Relays...

Page 13: ...Notes XEM External Mount Unit Installation and Operation Manual 2021 13...

Page 14: ...Notes 14 XEM External Mount Unit Installation and Operation Manual 2021...

Page 15: ...Notes XEM External Mount Unit Installation and Operation Manual 2021 15...

Page 16: ...au P 03 8301 9200 109 111 Northcorp Blvd Broadmeadows Vic 3047 2021 Armcor Air Solutions reserves the right to alter products and specifications without notice and does not accept responsibility for p...

Reviews: