6. SERVICING THE GENERATOR
MAINTENANCE SCHEDULE
The electrical safety may only be checked by personnel authorised for this task.
SERVICING WORK
CHECKING ELECTRICAL SAFETY
Servicing work should only be carried out by personnel qualified for this purpose.
All the works listed in the service plan are to be carried out in accordance with the
operating and service instructions for the motor.
We recommend that these works be carried out by an authorized service station.
Initial oil change should performed after first 5 hours of use. Thereafter change oil every 50
hours. Before changing oil, check for a suitable way to dispose of the old oil. Do not pour it
down into sewage drains, onto garden soil or into open streams. Your local zoning
environmental regulations will give you more detailed instructions on proper disposal.
Items marked with a “O” required advanced skill and tools, so they should be done by the
distributor.
Page 18
Maintenance
Schedule
After
first
5
Hours
●
Change
oil
.
Every
25
Hours
or
Annually
●
Check
starter
battery
.
Every
100
Hours
or
Annually
●
Change
oil
.
●
Clean
cooling
areas
.
●
Replace
spark
plug
and
set
gap
.
Every
200
Hours
Every
300
Hours
●
Replace
low
-
prof
le
air
cleaner
element
.
●
Check
fuel
filter
and
clean
or
replace
if
needed
.
●
Clean low-profile air cleaner element .
●
Check and adjust valve clearance when engine is cold.
Perform these procedures more frequently under severe, dusty, dirty conditions.
Have a Kohler portable dealer perform this service.
1
2
1
1
2
NOTE: