background image

SpecterOS4x Operation Manual 

Page 6 

 

CHAPTER 2                                  QUICK START

 

  

2.1 Mounting 

 

  
Ensure the weapon is unloaded. 
  

Loosen the mount lever locks and place the sight onto the rail.   Adjust the eye relief as per instructions in 
section 2.2  Once correct eye relief is set, tighten the mount levers to lock the sight to the rail.  Slots 
permit installation of wire ties.   

  
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 2-1   Levers lock sight to MIL-STD 1913 rail. 

  

 
2.2 ADJUSTING 

EYE 

RELIEF 

 

When viewing through the sight, proper eye relief causes the scene field of view to be a circular and 
sharp image, see Figure 2-2.    It may be necessary to move the optical sight either backwards or forward 
on the weapon in order to achieve the correct eye relief for the users natural shooting position. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

CORRECT 

 
 
 
 
 
 
 
 
 
 
 
 
 
                INCORRECT

  

(a) 

 

(b) (c) 

 

Figure 2-2   (a) Eye shown at proper 2.75 inch eye relief distance from rearmost glass surface. (b) Image 
through sight is sharp and circular when eye is placed at or near the proper eye relief distance.  (c) Image 
through sight when eye is too close to or too far from optimal viewing distance.   

  

Summary of Contents for SpecterOS4x Optical Sight

Page 1: ...SpecterOS4x Optical Sight Operation Manual ARMAMENT TECHNOLOGY INCORPORATED 3045 ROBIE STREET SUITE 113 HALIFAX NS B3K 4P6 CANADA sales armament com www armament com...

Page 2: ...2 QUICK START Page 6 2 1 Mounting Page 6 2 2 SpecterOS4x Operation Page 6 2 3 Quick Zeroing Page 7 2 4 Reticle Illumination Page 8 2 5 Changing the Battery Page 9 CHAPTER 3 OPERATION Page 10 3 1 Gener...

Page 3: ...r low light conditions The ballistically compensated reticle consists of a cross hair or chevron with horizontal stadia lines for shooting at various ranges The SFOV4 C1 model incorporates a Vertical...

Page 4: ...ter 32 mm Reticle Pattern Ballistic compensated crosshair Exit Pupil 8 0 mm Illumination LED Eye Relief 70mm Operating Temp 40 to 65 C Optical Axis Height 39mm Storage Temp 40 to 85 C Zeroing Range 60...

Page 5: ...Levers The locking levers are used to secure the sight to the weapon s Picatinny rail SpecterOS4x uses 2 ARMS type low profile locking levers that point rearward when locked The mount base also provi...

Page 6: ...point of impact to the right Each click moves the point of impact Minute of Angle MOA approximately at 100 yards 1 3 8 Reticle Illumination Knob Rotation of the knob illuminates the reticle at varyin...

Page 7: ...RELIEF When viewing through the sight proper eye relief causes the scene field of view to be a circular and sharp image see Figure 2 2 It may be necessary to move the optical sight either backwards or...

Page 8: ...OA approximately 1 2 at 100 yards Figure 2 4 Elevation zeroing uses the elevation dial the bottom rear of the mount Unlock the zeroing lock silver tab by raising it up as far as it will go Be sure tha...

Page 9: ...he centre of the crosshairs cross or chevron A Range Estimating and Drop Compensation Reticle Each reticle mode has multiple brightness settings and are set by the Illumination switch rotary on the le...

Page 10: ...umination switch to desired reticle brightness setting 2 5 CHANGING THE BATTERY To change the battery remove the battery cover by gripping the smaller diameter fluted section of the Illumination Switc...

Page 11: ...y For extra mounting security the mount provides slots to accommodate plastic or wire tie wraps so that the levers can be locked into their closed position The sight is now mounted on the weapon 3 3 M...

Page 12: ...back down fully 3 5 Zeroing Zeroing should be performed at 100 meters It is recommended that the marksman fires three round groups and make adjustments based upon the estimated geometric centre of th...

Page 13: ...w rotate With the lock disengaged rotate the elevation zeroing dial to the left to move the MPI down or to the right to move the MPI up RANGE IN METRES MPI MOVEMENT IN mm PER CLICK OF ADJUSTMENT MPI M...

Page 14: ...line also coincides with the 100 meter aiming point This reticle pattern is designed to be zeroed at 100 meters 3 6 2 A central aiming feature either a fine cross or a chevron is placed at the reticl...

Page 15: ...Vertical Subtention Optical Rangefinder VSOR allows the marksman to estimate the distance to targets by matching the height of a known object within the field of view The vertical distance for range...

Page 16: ...terDR sight in solvents DO NOT use hot water to clean the sight If mud or hardened dirt are on or near the lens Flush with cold or warm water and gently wipe with a moistened tissue Repeat the procedu...

Reviews: