Arlec LACTUNA MAL900 Installation Instructions Download Page 2

Arlec guarantees this product in accordance with the Australian Consumer Law.
Arlec also warrants to the original first purchaser of this product (“you”) from a retailer that this 
product will be free of defects in materials and workmanship for a period of 12 months from the date 
of purchase; provided the product is not used other than for the purpose, or in a manner not within 
the scope of the recommendations and limitations, specified by Arlec, is new and not damaged at 
the time of purchase, has not been subjected to abuse, misuse, neglect or damage, has not been 
modified or repaired without the approval of Arlec and has not been used for commercial purposes 
(“Warranty”).  
If you wish to claim on the Warranty, you must, at your own expense, return the product, and provide 
proof of original purchase and your name, address and telephone number, to Arlec at the address 
below or the retailer from whom you originally purchased the product within 12 months from the date 
of purchase. 
Arlec will (or authorise the retailer to) assess any claim you may make on the Warranty in the above 
manner and if, in Arlec’s reasonable opinion, the Warranty applies, Arlec will at its own option and 
expense (or authorise the retailer to) replace the product with the same or similar product or repair 
the product and return it to you or refund the price you paid for the product. Arlec will bear its own 
expenses of doing those things, and you must bear any other expenses of claiming on the Warranty.
The Warranty is in addition to other rights and remedies you may have under a law in relation to the 
product to which the Warranty relates.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. 
You are entitled to a replacement or refund for a major failure and for compensation for any other 
reasonably foreseeable loss or damage.  You are also entitled to have the goods repaired or replaced 
if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Arlec Australia Pty. Ltd. ACN 009 322 105 (“Arlec”) gives the Warranty.  
Arlec’s telephone number, address and email address are:
Customer Service: (03) 9982 5111
Building 3, 31 – 41 Joseph Street, Blackburn North, Victoria, 3130 
Blackburn North LPO, P.O. Box 1065, Blackburn North, 3130 

Email: [email protected]

wARRANTY

4

CPIN002354

5

6

NOTE: It is advisable to use a separate  
independent wall switch to ensure the simplest 
operation of this unit. 
In normal operation when first switched on,  
the unit will operate only in automatic mode. 
The unit will not operate the lamp in daylight. 
When dark, the light will be activated by  
movement across the detection area.
•  To switch off completely, switch the wall  
  switch to OFF.

This Sensor light has a built-in photoelectric cell 
that automatically senses daylight and keeps 
the light off during daylight hours.

NOTE:

1.  This highly responsive unit may occasionally  
  activate due to rapid environment changes.
2.  To avoid false triggering do not install this unit  
  near wiring of large appliances such as  
  air conditioners, refrigerators, fluorescent  
  lights etc.
3.  When first switching on allow approximately  
  30 seconds warm up time for sensor  
  operation to settle to normal sensitivity.

During daylight hours, the unit can be ‘walk’ 
tested by turning the daylight level (“LUX”) control 
fully clockwise. Test by switching the unit on and 
walk slowly across the detection area.
Check that the light will remain on for a period  
set by adjusting the timer, from approx 10 seconds 
to 3 minutes depending on the setting after  
the last movement in the sensing area occurs.
(Refer to adjusting the daylight level and  
time delay)

First, switch off the mains power to the unit. If 
unit has been operating, allow it to cool before 
handling. Open the lamp by unscrewing the 
fasteners on the front trim and diffuser, then 
remove the diffuser and remove/replace bulb, 

(use only 240 volt a.c. ES bulb 60 watt max), 
refit diffuser. Compact fluorescent bulbs may be 
fitted in this light. 

For normal operation, the daylight level (“LUX”) 
control is set to fully anti-clockwise. For walk 
testing in daylight the LUX control is set fully 
clockwise.
If you find in normal operation that you would 
like the light to come on sooner, adjust slightly 
back from the full anti-clockwise position. See 
figure 5 below. To adjust the time delay turn the 
time adjusting arrow clockwise to increase the 
delay and anti-clockwise to decrease the 
delay. The time delay is from approximately  
10 seconds to 3 minutes. It is recommended  
to use shorter time delays.

Detection Range : 

8 metres at 120° scan 

 

approx.

Time On (fixed) : 

10 s to 3 min approx.

Detection Circuitry :  Passive controlled 
 

infrared motion sensor.

Ambient Light  

<10 Lux adjustable 

required to operate 

to daylight  

in Auto Mode:
Maximum Globe : 

ES 60 watt max globe

Weatherproof Rating :  IP44

OpERATION

TROuBLE SHOOTING GuIDE

TO TEST

SpECIfICATIONS

mAINTENANCE

GLOBE REpLACEmENT

DAYLIGHT SENSOR  

(pHOTOELECTRIC CELL)

ADjuSTING DAYLIGHT 

LEvEL AND TImE DELAY

Note: Passive infra-red detectors are more sensitive in cold weather than warm weather.

pROBLEm

pOSSIBLE CAuSE

SuGGESTED REmEDY

Light does not switch ON when there 

is movement in the detection area.

1. No mains voltage.

Check all connections, and fuses/switches.

2. Globe faulty or missing.

Check. Replace.

3. Wiring incorrect.

Re-check.

4. Nearby lighting is too bright.

Redirect other lights or relocate unit.

Light switches ON for  

no apparent reason.

1.  Heat sources such as aircon. vents, 

heater flues, barbecues or very cold 

objects are near sensor.

Remove these sources if possible.

2.  Animals/birds e.g. possums or  

domestic animals.

Nil

3. Interference from on/off switching of 

electric fans or lights on the same  

circuit as your Sensor Light.  

(This problem does not always occur 

but a faulty switch or noisy fluorescent 

light may cause the Sensor Light to 

switch on.)

Should the false triggering become 

troublesome, consider:
(A) Replacing a faulty switch.
(B)  Replacing noisy fluorescent tubes 

and/or starters.

(C)  Connecting the Sensor Light to a 

separate circuit. (In most cases where 

one or more of the above suggestions 

have been carried out, false triggering 

has been reduced.)

4. Voltage surges

Nil

5.  Radio frequency transmissions from 

mobile phones, CB’s etc.

Nil

6. On during daytime.

Check daylight level (“LUX”) control is 

fully anti-clockwise.

Light remains ON .

1. Wiring is incorrect.

Recheck wiring.

2. Time delay set too long.

Turn time control anti-clockwise

To avoid dust build up and ensure proper functioning of the Sensor Light, wipe the sensor lens lightly 
with a damp cloth every 3 months. 
Care should be taken when cleaning to prevent scratching. A soft cloth or fine-hair brush should be 
used together with a nonabrasive cleaner. Do not use solvents or abrasive cleaners on any part of 
your Sensor Light.

Figure 5.

CPIN002354