USE THIS INSTRUCTION SHEET (290mm x 290mm) AS A TEMPLATE FOR HEAT LAMP & EXHAUST FAN INSTALLATION

CPIN002034/4

Specifications

Wattage:

Heat Lamps Hard Glass Infra red ES type 4 x 275W 240Vac

Reflector backed Lamp R80 ES 100W 240Vac

Airflow:

Output over 200m

3

/hour unducted

Dimensions:

From cavity floor (excluding fascia grille):

Height-195mm

Main body-290mm x 290mm

Outer flange-371mm x 371mm

Standard Accessories:

1 x Four gang wall switch

4 x Infra red Heat Lamps 275W

1 x Incandescent Reflector Lamp R80 100W

1x 1.5m Expandable duct piping

2 x 400mm Plastic ties (to hold duct in place)

1 x Duct outlet

8 x 30mm Cross recess, binding head, ZP self tapping screws

Introduction

Read these instructions carefully before installing & using the 

product. Keep the instructions handy for future reference.

IMPORTANT: Always operate the E550 from a power source of the 

same voltage, frequency and rating as indicated on the product 

identification plate.

The four infra-red lamps heat by direct radiation rather than heating the air in  

the room so the heat lamp & fan should be located directly over where drying  

off occurs.

Locate and install the product in accordance with the requirements of  

AS/NZS 3000 and local building codes. This appliance must be installed  

by a licensed electrician.

IMPORTANT: Do not install in a location where there is a possibility 

of water splashing onto the lamps. Do not install directly above 

bath or shower recesses or enclosures.

Electrical Requirements

This product is designed for wired-in installation and wiring and installation 

must be carried out by a licensed electrician in accordance with AS/NZS 3000. 

(Fig.01)

Wiring Diagram

                                                                                         Fig. 01 

IMPORTANT: 

Do not use this heat lamp & fan with any solid state control.

Fixed wiring insulation must be of a minimum 
V-90 temperature rating.

3 in 1 Heat Lamp 

& Exhaust Fan 

E550

 Instruction Manual

IMPORTANT: Please read these instructions carefully before use.

Due to continuous research and development the specifications herein are subject to change without notice.

Safety Instructions

WARNING: To reduce the risk of personal injury or damage to 

property, follow basic safety precautions when using this product, 

including the following:

•  This appliance is not intended for use by persons (including children) with 

reduced physical, sensory or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision or instruction concerning 

use of the appliance by a person responsible for their safety 

•  Children should be supervised to ensure that they don’t play with the appliance
•  Do not look directly at heat lamps when they are operating.
•  Do not operate the unit without the outer surround being in place.
•  Do not install in a location where there is a possibility of water splashing onto 

the lamps.

•  Do not install directly above bath or shower recesses or enclosures.
•  Do not install the control switch in a location that is accessible by a person in 

the bath or shower.

•  Do not operate any product which appears damaged in any manner or after 

product malfunctions, has been dropped or damaged. Consult a qualified 

technician to check the product before further use.

•  Do not operate this product in the presence of explosive / flammable liquid 

or fumes such as where aerosol (spray) products are being used or where 

oxygen is being administered.

•  Do not insert or allow foreign objects to enter any ventilation or exhaust 

opening as this may cause an electric shock or fire, or damage the appliance.

•  Switch off from power supply when cleaning. Allow all parts to cool 

thoroughly before disassembling / assembling parts or replacing lamps.

•  Do not use the product for other than its intended use as described in these 

instructions. This product is intended for domestic household use only. The 

use of accessories, attachments or lamps other than those recommended by 

the manufacturer may cause safety hazards.

NOTE: Electrical fittings must be installed by a licensed electrician 

or other persons authorised by legislation to work on fixed wiring 

of an electrical installation.

Ventilation Requirements

For maximum efficiency and fan performance please note these key points 

when installing the heat lamp:

Sufficient air inlet into room

Steam will only be removed if there is sufficient flow of air through the room . 

Ensure generous inlets exist through windows vents or under the door. Air flow 

path from inlet to fan should ideally pass over the steam sources. (Fig.02).

 

Fig. 02

Adequate ventilation in roof cavity

It is essential that there is adequate space within the roof cavity so the exhaust 

air from the heat lamp & fan can dissipate. The roof cavity itself should be well 

ventilated to the outside so the moist air can be removed.

Where ventilation space is restricted, such as between floors of multi-story 

building, or where space within the roof cavity is severely restricted, install the 

supplied flue duct and vent to an outside area.

Clearances around the product

A minimum clearance of 75mm is required above the top of the product (dim. A) 

when installed in a well ventilated roof cavity. When ventilation is restricted, 

this clearance should be increased to a minimum of 100mm. A minimum space of 

245mm is required in the ceiling space (dim. B) where there is good ventilation to 

the sides of the unit. (Fig.03).

 Side Elevation

                             Heat Lamp & Exhaust Fan             Fig. 03

Additionally, a minimum of 15mm clearance is required between the two vertical 

sides of the heat lamp & fan and any adjoining parts of the roof structure, such 

as walls, joists or insulation batts.

Do not allow insulation material to rest against the sides or the top of the heat 

lamp & fan when it is installed.

(B)

(A)

15mm

A minimum 

of 15mm 

required on 

two vertical 

sides

Bathroom Plan

Heat Lamp & 

Exhaust Fan

Air Flow

Earth
Neutral
Active

S/W Light
S/W Fan
S/W Heat
S/W Heat

Reviews: