CSF6060 Instructions A5 x 8 pages CPIN003215
Fig 7
8 Wire-in the fan unit as shown in figure below:
(a) Firstly connect internal wiring by clipping
connectors together (push into locked position),
then (b) connect mains active, neutral and earth
wires to supply terminal block on mounting
plate.
Fig 8
IMPORTANT NOTES:
Means of disconnection must be incorporated in
the fixed wiring in accordance with the wiring
rules.
Incorrect wire connections will damage this unit
If this fan is a replacement fan for an existing
fan, remove any controller unit.
Fig 9
Note: Ensure that all earth wires are connected to
the supply earth.
9 When wiring has been completed and checked,
slide the top canopy upward over the mounting
bracket and tighten the fixing screws. Slide the
support pin cover downward into position over
the collar of the motor housing.
10 Blade attachment
Insert the blades to the motor housing and
secure each blade with two screws, nuts and
washers. Tighten the screws firmly without over
tightening. Repeat this procedure for all the
blades. Spanner and Philips head screw driver is
recommended for this job.
Fig10
Attach the plastic fixture to each end of the blade
and secure it with screws provided .
Fig11
11 Attach the glass lamp shade and lock it into
position by turning it clockwise. Be careful not to
damage the LED lamp assembly beneath.
Fig 12
OPERATION :
The fan is operated using the transmitter handset.
IMPORTANT: By default the remote included
in the box is paired with the fan with which it
is supplied.
To pair the transmitter and receiver units
together follow the steps as given below.
2
3
THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK
1 Choose a location for the fan which will ensure
adequate clearance from all objects and walls
and with blade height greater than 2.1 metres
from the floor.
2 At the selected mounting position, check whether
there is a ceiling joist to which the fan can be
secured. If there is no suitable supporting
member, install a 50 x 100mm brace between
ceiling joists. Secure the mounting bracket to the
ceiling with four mounting screws and washers.
If a safety cable is provided with the fan, anchor
this securely to the supporting member or
mounting bracket when wiring has been
completed.
Mounting Bracket
Fig 1
3 Attach the light assembly to the main body.
Firstly clip the connecting leads together, then
place the mounting holes in the base of the light
assembly over the screw heads in the main body.
Fig 2
Rotate the light assembly clockwise to lock into
position, then tighten screws.
Be careful not to damage the exposed LED’s of
the light assembly.
Fig 3
4 To enable the fan wiring the ball joint pin needs
to be removed by the following method.
A Unscrew the locating screws
B Slide the ball joint downwards
C Remove pin and the push the ball joint out
from the downrod.
Fig 4
Feed the fan supply wires from fan motor
housing through the downrod with upper and
lower canopy fitted.
Fig 5
5 Insert ball joint pin into the downrod and fasten –
reverse procedure to above.
6 Attach the downrod to fan motor housing by the
following method.
A Remove the locating clip and support pin
B Loosen the fixing screws
C Place the downrod into the collar in the top
of the motor housing.
D Replace the support pin and locating clip
E Fasten fixing screws
Fig 6
7 Hang the fan motor housing on to the mounting
bracket, ensure the ball joint locating groove
aligns with the notch on the mounting bracket.
Fan
Supply
Wires
Motor
Housing
Locating
Screw
Ball Joint
Down Rod
Pin
Locating
Groove
Supply Active
Switch
Supply Neutral
Brown
Brown
Blue
Blue
Gr
een/Y
ell
ow
Green/Yellow
Supply Earth
To Mounting Bracket
L
N
To Motor & Lamp
[through download]
Blade
Nuts
End Cap
Screw
Blade
This product incorporates a self learning code
system:
A Fit 12V Type 23A battery into the transmitter
B Turn on the supply to the fan.
C Within 30 seconds of turning on supply to the fan,
press and hold the FAN ON/OFF button on the
transmitter for 5 seconds.
D A beeping sound is emitted when pairing is
complete (a beep is also emitted when a signal
has been sent from the transmitter).
Note: The transmitter code is not accepted for
pairing after supply has been ON for more than 30
seconds.
Pairing more than one fan:
When more than 1 fan is installed e.g. FAN A & FAN
B, and pairing is required each fan needs to be
paired separately. Follow the steps given below to
pair the fans:
1 To pair turn the Power ON to one fan only e.g.
FAN ‘A’ and within 30 seconds of turning ON the
power to the fan ‘A’, press and hold the FAN ON/
OFF button on the transmitter ‘A’ for 5 seconds.
When a long beep is heard the fan is paired.
2 Turn OFF the supply to FAN ‘A’ which is paired
and turn ON the supply to the other fan, FAN ‘B’.
Repeat steps C &D to pair it. To transmitter ‘B’.
3 Once Fan ‘B’ is paired, turn ON the supply to the
first fan, FAN A. Both the remotes are paired and
will work independently. Note: If the battery is
removed / replaced the fan needs to be paired
again.
Note: Each fan must have its own means of
disconnection incorporated in the fixed wiring in
accordance with the wiring rules.
If this fan is a replacement, remove any existing wall
speed controllers.
TRANSMITTER HANDSET FUNCTIONS
1. FAN ON/OFF: Press and release button to switch
fan motor OFF and ON.
2. LIGHT OFF/ON: Press and release button to
switch light off and on.
3. FAN SPEED: Fan speed can be adjusted up to 6
different speed settings with buttons marked ‘+’
& ‘-’. By default when the fan is switched ON
with the ON/OFF button, the fan will start to
function at 3rd speed setting. Adjsut the fan at
desired speed setting with ‘+’ & ‘-’ buttons.
4. TIME OFF: Press the button marked “ ” to set
the preset desired time off function of 1-2-4-
8hrs. Each press of the button will change the
time off duration from 1-2-4-8, blue LED
indicator corresponding to set time will glow.
5. LED INDICATORS: Light illuminates to show that
a function has been initiated. The LED indicators
will switch off after a few seconds, this is to
extend the life of the battery. Press the fan speed
adjustment button if you want to check the speed
or the timer off setting.
6. 12V battery required, Type 23A.
NOTE 1: A beep will be heard and the Blue
indicating LED will illuminate when a function
is activated.
NOTE 2: The remote control includes a memory
function. This function records the status when
power has been disconnected to allow resumption
when power is restored.
NOTE 3: Remove the battery from the transmitter
handset when left unused for extended periods.
Pairing is required after the battery is replaced.
NOTE 4: To change the direction of rotation for S/W
function the fan needs to be turned OFF & ON for
settings to take effect.
NOTE 5: Only 1 remote can be paired with a given
fan at any time.
NOTE 6: If the power supply is turned OFF and back
ON the light will come on automatically, use the
remote to turn the light OFF.
3.
4.
6.
5.
2.
3.
1.
Fig 14
Fig 13
Flat Washer