OPERATION:-

Make sure your read all the safety warning before you operate this unit for the first time. 

ON / Speed Button:-

Plug the unit to a standard mains socket and turn on the mains switch. Press the ON/ Speed 

button to start the unit. The unit will beep twice and will be in a stand-by status, all buttons will 

be in active unless you press the ON/Speed Button. Each time the unit is turned on it will be in 

Normal Mode of operation with the wind speed setting on medium. The wind speed setting will 

stay on medium speed for 3 Sec and will switch back to low (Lo) speed setting automatically 

unless changed to a different setting. 
Press the button repeatedly to change the fan speed – Low, Medium and High and the 

corresponding speed indicator LED will glow on the display panel

Off Button 

To turn the unit off press this button once and the unit will be turned off. 

Swing Button 

Press this button and the unit will swing sideways and swing indicator LED will glow on the 

indicator. Press this button again and the unit will stop oscillating.

Timer Button 

Set the Timer to a desired operating time (0.5 Hour to 7.5 Hours) by pressing the Timer button 

repeatedly. Each time the button is pressed the time interval is incremented by 0.5hrs and the 

corresponding time setting will be displayed on the seven segment display. 
0.5h

1h

1.5h

2h……

7.5h

0

back to 0.5h

When the set time has been reached the unit will shut off automatically and will stay in a standby 

mode. 

Cool / Humidifier Button 

Press this button and the unit will beep once and will start its cooler and humidifier function and 

the corresponding indicator LED will glow on the display panel.  

This function is recommended for higher/ efficient cooling effect under any mode. 

Warning:

 Please do not use Cooler / Humidifier function when there is no water in water tank 

this may result in a noisy operation and will damage the motor permanently. 

Mode Button 

Change the mode to the desired type (Normal, Natural and Sleep) by pressing the Mode button 

repeatedly. 

Normal Mode:- 

When the unit is turned ON it will stay in Normal mode and the corresponding LED will glow on the 

display panel. Under this mode the fan speed remains constant at set speed (Low / Medium/ High). 

This mode is recommended for normal operation 

Natural Mode:- 

Press the Mode button until the LED corresponding to the natural mode glows on the display 

panel. Under this mode the fan speed varies randomly (Low/Medium/High and off) giving the 

effect of natural breeze.  

It is recommended to set the fan speed to high under this mode for a better result. 

AEC007 Instructions.indd   4

2/08/11   10:25 AM

Summary of Contents for AEC007

Page 1: ...Instruction Manual Important Please read these instructions carefully CPIN002242 Model AEC007 AEC007 Instructions indd 1 2 08 11 10 25 AM ...

Page 2: ... be replaced by a qualified electrician DO NOT use the unit without the filter fitted DO NOT allow objects to enter any ventilation or exhaust other than ice or water as specified in these instructions This unit is intended for indoor use only ALWAYS unplug the unit from the mains before maintenance or cleaning ALWAYS use the switch on the control panel to start and stop the unit ALWAYS keep a cle...

Page 3: ...r Storage tank 7 Caster wheels 8 Dust Filter 9 Honey Comb cooling pad 10 Water inlet 11 Mains power cord 12 Drain Cap 1 On SPEED Button 2 Cooler Humidifier Button 3 Time Button 4 Ion Generator Button 5 Mode Button 6 Swing Button 7 Off Button 1 2 3 4 5 10 11 12 6 7 8 9 1 1 2 3 4 2 3 4 5 6 5 6 7 Remote Control AEC007 Instructions indd 3 2 08 11 10 25 AM ...

Page 4: ... interval is incremented by 0 5hrs and the corresponding time setting will be displayed on the seven segment display 0 5h 1h 1 5h 2h 7 5h 0 back to 0 5h When the set time has been reached the unit will shut off automatically and will stay in a standby mode Cool Humidifier Button Press this button and the unit will beep once and will start its cooler and humidifier function and the corresponding in...

Page 5: ...ator will be on Under this mode negative Ions are blown throughout the room by the fan to neutralize the positive charge in the particles of smoke and dust that float in the air thereby losing their energy will no longer remain in the air The combination of negative ions on bacteria may deter the bacteria growth or even kill the bacteria Negative ions are effective in creating a cleaner and more s...

Page 6: ... water level indicator on the front of the unit Once the tank is filled put back the storage tank cover Always use clean water To drain the water when the unit is not in use 1 Position a water tray flat on the floor beneath the drain hole 2 Unscrew the drain cap at the bottom of the unit and then remove the water plug from the drain hole allowing the water to drain out Refer to the figure below 3 ...

Page 7: ...ays switch off and unplug from the mains supply before attempting any kind of cleaning and maintenance After extended period of use replace the water in the tank with fresh water The air filter only at the inlet at the rear of the unit can be cleaned if required The filter should be cleaned in a mild soapy solution then left to dry before replacing External enclosure can be cleaned with a damp clo...

Page 8: ...roduct and proof of purchase must be returned pre paid by you to the place of purchase This guarantee is in addition to and does not take away from any other rights and remedies you may have under any relevant law Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any othe...

Reviews: