III. Operating Process

Turn on power switch, temperature
light is ON. The digital display shows

.

Press

button, the

light is

on (C denotes Celsius). Press
arrows “

” or “

” to select “

” or

” (F denotes Fahrenheit)

according to your habits.

Press

button, the temp

light

is ON. Press Up “

” or Down “

button to set temperature according
to different transfer material.
(Normally 180

~200

)

Note:

Temperature will be shown on

the controller only after it reached to

100

,

it’s normal that there is no

temperature shows right after the
setting.

2. Set time required

Press

button after the

temperature setting and the

time light is ON. Press Up “

” or

Down “

” button to set time

according to different transfer
material.

Press

button after time setting;

the display shows the temperature
starts to rise. “CD-L” shows the time
counting down during your transfer.

If there is a difference between the
actual temperature and temperature
shows on the controller, you can
use

P5 mode

to calibrate the

difference.
For example, when actual heat
platen temperature is 180 °C but the
display shows 200°C, press
button for 5 seconds to enter the P5
mode. When enter P5 mode,
press UP button

“△”

to set to -20,

and then press

button again

for 5 seconds return to operation
mode. In the contrast, when actual
heat platen temperature is 200 °C
but the display shows 180°C, press

Summary of Contents for UHP-15MS

Page 1: ...kiPress_HP7 HP8E Model No UHP 15 20MS CONTENTS I Assembly Drawing 2 II Technical Parameters 2 III Operation Process 3 4 IV Maintenance 5 V Trouble Shooting For Transfer Print Quality 5 VI Circuit Diagram 6 VII Explosion View 7 8 ...

Page 2: ...Model No UHP 15 20MS 2 Machine Dimensions 706 410 433mm 3 Heat Platen Size 38x38cm 40x50cm 4 Printable Articles Max Size 400 500 10mm 5 Voltage 220V 1 Phase 120V 1 Phase 6 Power 220V 1 8KW 110V 1 6KW 7 Recommend Setting 30 280s 180 210 Time Range 0 999s Maximum Temp 225 C ...

Page 3: ...on after the temperature setting and the time light is ON Press Up or Down button to set time according to different transfer material Press button after time setting the display shows the temperature starts to rise CD L shows the time counting down during your transfer If there is a difference between the actual temperature and temperature shows on the controller you can use P5 mode to calibrate ...

Page 4: ...ransfer Paper instructions on whether to peel cold or hot Here are suggested Pressing time guidelines for different transfer paper Ink Jet Transfer Paper fabric 14 18 seconds Laser Copier Printer Transfer Paper fabric 18 25 seconds Sublimation Transfers onto Fabrics 25 30 seconds Sublimation Transfers onto FR Plastic Woods 60 70 seconds Step 8 Mouse pads coasters and other thicker materials may al...

Page 5: ...e of working Press the Limit Switch Time controller shows no countdown 1 Checking the connection of Limit Switch if it s loosened 2 Checking the switch whether it s pressed properly 3 If above steps are good maybe the Limit Switch is broken 6 The heat platen is heating well but the Time Controller countdown even the platen is not pressed down Checking the two cables of Limit Switch whether they ar...

Page 6: ...or quality transfer paper 4 If transfer paper stick to the object after transfer the temperature is too high or poor quality printing ink VI Circuit Diagram K0 Power Switch FU Fuse T Transformer EH1EH2 Heating Pipe SJ Digital Controller R1 Relay ...

Page 7: ...Plain Heat Press Manual 7 VII Explosion View ...

Page 8: ...ng Screw Rod 1 32 M10 Hand Wheel 1 33 Coiler Joint 2 34 Thermal Insulation Baffle 4 35 U Shape Plate 1 36 M6 Flat Head Cross Screws 4 37 Drawer plate 2 38 Under Plate Pillar 4 39 PWB M3 1 40 Drawer Handle 1 41 Sliding Rod 1 44 PWB M4 1 45 Plain Mat 28 8 5 2 46 M4 Hex Screw 4 47 Under Plate38 38 4 48 Electric Box Panel 1 49 Electric Box Cover Left 1 50 Electric Box Cover Right 1 51 Joint 1 52 Power...