background image

 
 

 

Technical Data   

2" Sand Separator Batteries 

 

Metric 

US 

HYD-2 

HYD-3 

HYD-4 

HYD-5 

HYD-2 

HYD-3 

HYD-4 

HYD-5 

Connection diameter 

110mm 

110mm 

160mm 

160mm 

4 inch 

4 inch 

6 inch 

6 inch 

Maximum pressure 

10 bar 

145 psi 

Maximum temp. 

70ºC 

149º F 

 
Separation Efficiancy / Flow Rate 

 

Particle size larger than (micron): 

m

3

/h 

gpm 

150 

100 

50 

HYD-2 

HYD-3 

HYD-4 

HYD-5 

HYD-2 

HYD-3 

HYD-4 

HYD-5 

Ef

fi

ci

e

n

cy

 

90 

85 

82 

30 

45 

60 

75 

132 

198 

264 

330 

95 

90 

85 

40 

60 

80 

100 

176 

264 

352 

440 

98 

95 

90 

50 

75 

100 

125 

220 

330 

440 

550 

 

Headloss Chart 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sand Separators Orders from:

www.irrigationglobal.com

Summary of Contents for 2" Sand Separator

Page 1: ...Arkal Sand Separator Operation Service Maintenance Manual Sand Separators Hydrociclone Batteries by www irrigationglobal com ...

Page 2: ...ing the filter 3 Installation of the filter should be performed so as to avoid direct water contact with the electronic control unit 4 Confirm that filter weight when full does not exceed support construction limitations 6 Prior to installation confirm that line pressure does not exceed filter s operational pressure rating 10 bar 7 Please note that during normal operation the filter enters into ba...

Page 3: ...ontrol valve normally activated by a controller usually triggered by time or set volume Sand Separator Technology Hydrocyclones operate effectively and efficiently under a set flow rate Constancy of flow rate and adaptability of design enhance efficiency further When flushed regularly cyclones require minimal maintenance The Hydrocyclone is a function specific product designed for the removal of s...

Page 4: ...ve 3 The signal is transmitted to the sand collector s draining valve This valve opens and then from the collector releases the sandy water to the drain 4 The flushing proceeds to is taking approximately 20 second Battery Installation 1 Pay careful attention that the inlet and outlet are correctly installed see arrows on the manifold 2 Connect backwash waste line to the drain Control System Instal...

Page 5: ...m pressure 10 bar 145 psi Maximum temp 70ºC 149º F Separation Efficiancy Flow Rate Particle size larger than micron m3 h gpm 150 100 50 Efficiency 90 85 82 15 66 95 90 85 20 88 98 95 90 25 110 Headloss Chart Sand Separators for Water Filtration Batteries by www irrigationglobal com ...

Page 6: ...um pressure 10 bar 145 psi Maximum temp 70ºC 149º F Separation Efficiancy Flow Rate Particle size larger than micron m 3 h gpm 150 100 50 HYD 2 HYD 3 HYD 4 HYD 5 HYD 2 HYD 3 HYD 4 HYD 5 Efficiency 90 85 82 30 45 60 75 132 198 264 330 95 90 85 40 60 80 100 176 264 352 440 98 95 90 50 75 100 125 220 330 440 550 Headloss Chart Sand Separators Orders from www irrigationglobal com ...

Page 7: ...over 2501 0222 RPA 4 Erosion preventer 2200 0022 EPDM 5 Cover seal 5005 0002 EPDM 6 Clamp 5042 0030 SS 7 Filter body complex 2218 0003 8 2 nipple 5020 0051 PVC 9 Filter body 2200 2219 RPA 10 Gauge ports seal 5006 0004 EPDM 11 Gauge ports nut 2511 0103 RPP 12 2 cap 2511 0200 RPA Sand Separators and Spares Orders from www irrigationglobal com ...

Reviews: