Pre-installation checks
Installation of a fireplace must be according to local codes and regulations in each
country.All local regulations, including those which refer to national and
European standards, must be observed when installing the product.
Both an installation manual with technical data and a manual on general use and maintenance
are enclosed with the product. The installation can only be used after it has been inspected by a
qualified inspector. A name plate of heat-resistant material is affixed to the product. This
contains information about identification and documentation for the product.
Installation introduction with technical data
1.0 Technical data
Material: Cast iron
Finish: High-temp. Resistance paint
Fuel: Multi-fuel
Log length, max.:34.7cm
Flue outlet: Top and rear
Flue pipe dimension:
- Inside:- 3 -125 mm/113cm
2
cross section
Approx. weight:
99
kgs
Dimensions, distances etc.:figure2
Parameter
Wood Logs
Ancit
Total Efficiency
%
75.2
72.1
Nominal heat output
kW
7.5
6.6
Mean CO emission (at 13 % O
2
)
%
0.12
0.26
Mean flue gas temperature
ºC
347
303
Flue gas mass flow
g/s
6.2
6.4
Mean C
n
H
m
emission
Nmg/m
3
112
95
Mean NOx emission
Nmg/m
3
102
124