![Aritech VV600 Planning And Installation Manual Download Page 24](http://html.mh-extra.com/html/aritech/vv600/vv600_planning-and-installation-manual_2972067024.webp)
Planning and Installation manual VV600/VV602Plus
22
5.5.3. The movable mounting plate kit VM651P
The VM651P movable mounting kit is designed to enable movable (day/ night)
mounting of VV600Plus and VV602Plus on vault and safe doors.
1.
The night position plate shall be mounted close to the keyhole or the code
wheel on the door (the night position plate has a little tap in the right-hand
corner). The best way to connect the VM651P is in series with the alarm relay
of the detector. This way the system can only be armed when the detector is in
the night position.
2.
Mark the three mounting holes. Drill/tap holes for the three M4 bolts as
described in chapter 5.2. Make sure the holes you drill in the door does not
damage the locking mechanism.
3.
Mount the night position plate using M4 bolts.
4.
Mount the junction box and day position plate together on the side of the safe
or on the wall close to the detector in such a way that the cable prevents
opening the door.
5.
On metal surface mount exactly as the night position plate. On other surfaces
than steel suitable screws and expanders have to be selected by the installer.
6.
Mount the VV600/602Plus detector on the base plate of the VM651P kit with
the three screws supplied.