© 2020 Carrier
1 / 4
P/N 141795999-
2 (ML) • REV C • ISS 07DEC20
ST400 Pry-off Tamper Kit Installation Sheet
EN IT
1
2
EN: Installation Sheet
Description
Figure 1: Mounting
(1) Wall plug
(2) Screw
(3) Hole for pry-off tamper
(4) Detector base
(5) ST400 pry-off tamper
(6) Small screw
Figure 2: Connections
1
−0V
2
+12V
3, 4 Alarm
5
Spare
6, 7 Tamper
8
LED
(T) Tamper loop
1. Break out the hole for the pry-off tamper (Figure 1, item 3)
in the base of the detector (item 4).
2. Use the base as a template for marking the position of the
screw (item 2) in the wall.
3. Affix screw (item 2) to the wall.
4. Affix ST400 (item 5) to the base (item 4) using the smaller
screw (item 6).
5. Adjust screw (item 2) so that the ST400 switch closes
when the base is in its final position.
6. Install the detector following the mounting instructions.
7. Connect the ST400 in tamper loop as shown in Figure 2.
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
Carrier Fire & Security Americas Corporation Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
(1)
(2)
(3)
(4)
(5)
(6)
(T)