![Aritech AS522 Installation Manual Download Page 2](http://html1.mh-extra.com/html/aritech/as522/as522_installation-manual_2972109002.webp)
+
-
-
-
-
- 2 -
Wiring procedure:
First, wire the control panel (power down) to the siren as shown, before
connecting the battery. When the battery is connected for the first time, the
siren will give a short beep. The siren cannot be activated until all inputs (input
power and hold-off voltages) are correct. The siren will be activated if the
Jumpers:
GND
GND
4700
W
4700
W
4700
W
33
W
0 V
LED
Isolated
Isolated
E O L
-
Tamper Loop (T5/T6)
Tamper
Tamper
-
Ex-factory
Beacon
Terminal 1
0 V
Siren Timing
Siren
Terminal 2
14 4420 999-1
© 2000 Interlogix BV. All rights reserved.
ISO certified
Technical data:
Supply voltage:
10.0 V - 14.5 VDC
Standby current:
40 mA (typical)
Operating current:
350 mA (typical) (incl. beacon)
Sound output:
114 dB at 1 m;
85 dB at 3 m
Frequency sweep:
0.58 - 3 kHz
Operational timer:
20' (ex-factory)
Working temperature:
-25°C to +55°C
Weight:
1 kg
Dimensions:
300 x 210 x 55 mm
Standards:
According to: IS 199
Recommended battery:
- Lead acid: (optional)
Type
12 V - 1.2 Ah
Load voltage
min 13.6, max 14.2 VDC
- NiCd:
(ex-factory)
Type
6 V - 280 mAh
Load current
20 mA (typical)
Tamper:
28 VDC; max. 100 mA
Beacon:
Operating current:
110 mA
Light output:
100.000 peak lumens
Life time:
1.000.000 flashes
Flash rate:
60/minute
Spike suppression network: Standard fitted
20
minutes
Standard ex-factory settings:
Ex-
factory
J10
Red = Alarm
Green = OK
EOL
Active
Active
Cut J8 & J9
Red
Green
1
2
3
4
5
6
7
8
9 10 11
-
+
+
+
-
-
1K
1K
Typical single-siren wiring for Irish panels:
Beacon
Siren
+V
Tamper
GND
-Ve
tamper
return
AUX.
supply
EXT. bell
INT. bell
J 8
J 9
2-siren wiring configuration:
J10
input power is removed or drops significantly or if the siren hold-off voltage
is removed.
When using an Aritech control system or any other control system which
requires 4k7 end of line resistor, cut J8 to use built in end of line feature.