Summary of Contents for 1200C

Page 1: ...1200C 2000C Fire Alarm Control Panel and Repeater User Manual P N 10 3311 505 1003 01 ISS 18DEC14 ...

Page 2: ...nsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see www recyclethis info 2006 66 EC battery directive This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union See the pro...

Page 3: ...ser interface controls 2 General indicators 4 Controls buttons and indicators 6 Sounder buttons and indicators 7 Fire brigade buttons and indicators 8 Repeater buttons and indicators 9 Zone indicators 10 Operation 11 Panel operation in standby 11 Panel operation in fire alarm 12 Panel operation in pre warning 13 Panel operation in fault 14 Maintenance 15 Fire alarm system maintenance 15 Battery ma...

Page 4: ...is product contact your installation or maintenance contractor Limitation of liability Installation in accordance with this manual applicable codes and the instructions of the authority having jurisdiction is mandatory UTC Fire Security shall not under any circumstances be liable for any incidental or consequential damages arising from loss of property or other damages or losses owing to the failu...

Page 5: ...el interface indicators and controls The control panel interface Figure 1 The control panel interface 1 LCD screen 2 Alphanumeric keypad 3 Fire brigade buttons and indicators 4 Key switch 5 Sounder buttons and indicators 6 Repeater buttons and indicators 7 Controls buttons and indicators 8 Zone indicators 9 General indicators ...

Page 6: ...itch in any position User interface controls The user interface has 20 buttons 10 of which are alphanumeric The remaining 10 are described below Table 2 Description of the control panel user interface controls Button Description Alpha selection when using the alphanumeric buttons Display the most recent alarm Print the current screen Scroll between Alarm Fault and Conditions View additional inform...

Page 7: ...1200C 2000C Fire Alarm Control Panel and Repeater User Manual 3 Button Description Increase a value Decrease a value ...

Page 8: ...LED 5 System fault LED 6 Processor running LED 7 Supply On LED Table 3 Description of general indicators LED indicator Description Fire Alarm Two red LEDs indicate a fire alarm Fault A yellow LED indicates one or more of the following general faults Device fault Supply fault Processor fault Bell fault Communications fault Fire brigade fault Any test mode Any disablement ...

Page 9: ...n earth fault System fault A yellow LED indicates one or more of the following Internal memory failure Clock failure Watchdog time out Tamper switch Service switch Logic error Memory lock No checksums calculated Hardware test fault Fireman s panel down Repeater down Panel down Global repeater down Input fault Output fault Configuration fault Checksum fault Protected memory overwritten Time date wr...

Page 10: ...on The buzzer sound is Constant for a fire alarm Fast intermittent for a fault warning Slow intermittent for a condition warning Press the Silence Buzzer button to silence the buzzer A steady yellow LED indicates that the buzzer has been silenced Reset Enabled Press this button to reset the fire panel Disable Enabled Press this button to display the Disable menu on the LCD screen The yellow LED in...

Page 11: ... LED indicator Key switch position Description Sound A red LED indicates that the sounders are activate sounding Delay ON OFF A single LED indicates that the sounder delay has been toggled ON or OFF Fault Disable Enabled Press the Fault Disable button to disable the sounders The LED flashes when a fault is detected and is steady when the sounders are disabled Silence Enabled A yellow LED indicates...

Page 12: ...l Enabled Push this button to activate the fire brigade notification A red LED indicates that a signal has been sent Delay ON OFF The LED indicates that the fire brigade delay has been toggled ON or OFF Fault Disable Enabled Push this button to disable the fire brigade notification The LED is steady when the feature is disabled and flashes when a fault is detected Stop Fire brigade Enabled Push th...

Page 13: ... to be emulated 3 Press the Enter button To stop emulation 1 Press the Panel button 2 Press 0 3 Press the Enter button When a global repeater is emulating a panel it is not necessary to stop emulation before emulating another panel The global repeater will automatically stop the emulation before trying to emulate another panel Local repeater Press the Panel button to start emulating the panel Emul...

Page 14: ...al Zone indicators Each zone has two LED indicators A red LED indicates a fire alarm and a yellow LED indicates a fault The zone fault LED flashes when there is a fault and remains steady if the entire zone has been disabled Figure 7 Zone fire and fault indicators ...

Page 15: ...Delay ON LED is steady when a delay is running This is logged as a condition Press the SILENCE BUZZER button to silence the internal buzzer All other LEDs OFF Figure 8 System Status menu normal operation SYSTEM STATUS Fri 12 10 04 09 17 37 Site text up to 40 characters Site text up to 40 characters Scanning Day Mode Zones on E Alarm 0 Faults 0 Cond 0 P 1 SDZ 1 Menu title date and time 2 Site text ...

Page 16: ...re than one fire alarm exists use the up and down arrows to view each alarm 4 Press Silence Buzzer to silence the internal buzzer and to acknowledge the alarm 5 Once the evacuation of the building is complete silence the sounders by turning the enable disable key switch to enable see Key switch on page 2 6 Press the Silence button The yellow Silence LED is steady 7 If you need to restart the evacu...

Page 17: ...ample shown above the pre alarm is in zone 6 area 1 at address 12 in loop 1 2 If more than one pre warning exists use the up and down arrows to view each pre warning condition 3 Press Silence Buzzer to silence the internal buzzer and to acknowledge the pre warning 4 Investigate the cause of the pre warning condition 5 When the pre warning condition is under control turn the enable disable key swit...

Page 18: ...ols A specific zone has been placed in test mode The fault remains until the test is complete Fault Disable Sounders The sounders are disabled or there is a fault with the connection Enable the sounders If the fault continues check the connections Fault Disable Fire brigade The fire brigade notification has been disabled or there is a fault with the connection Enable the Fire brigade notification ...

Page 19: ...ay has received attention Quarterly Check the log book entries and ensure that any necessary action has been taken Check the state of the batteries and corresponding connections Visually inspect the control panel for signs of moisture and other deterioration Test the alarm fault and ancillary functions of the fire panel Yearly Carry out the recommended daily and quarterly inspection and test routi...

Page 20: ...he panel That the control panel event log does not indicate a mains failure in the last twenty four hours If the leads are in good condition all connections are correct and the control panel continues to report that the test has failed twenty four hours after the last mains failure then the batteries should be replaced immediately Replacing batteries To replace the batteries 1 Disconnect and remov...

Page 21: ... to fire protection equipment 7 11 Delay to output 7 12 Dependency on more than one alarm signal 7 13 Alarm counter 8 4 Total loss of the power supply 9 5 Disablement of addressable points 10 Test EN 54 2 compliance for control panels with the VDS2000 module Control panels with the VDS2000 module installed have the following options with requirements according to EN 54 2 Table 11 EN 54 2 options w...

Page 22: ...5 2011 For detailed information refer to the product Declaration of Performance DoP Table 12 Certification Certification body 1134 Manufacturer UTC CCS Manufacturing Polska Sp Z o o Ul Kolejowa 24 39 100 Ropczyce Poland Authorized EU manufacturing representative UTC Fire Security B V Kelvinstraat 7 6003 DH Weert The Netherlands Year of first CE marking 09 Declaration of Performance number 360 3315...

Page 23: ......

Page 24: ......