background image

1

TH 721 D22 B/LPG

TH 721 D22 B/NG

TH 721 D22 B/TG

TH 731 D2/A B/LPG

TH 731 D2/A B/NG

TH 731 D2/A B/TG

TH 931 D2/A B/LPG

TH 931 D2/A B/NG

TH 931 D2/A B/TG

TH 721 D22 E/LPG

TH 721 D22 E/NG

TH 721 D22 E/TG

TH 731 D2/A E/LPG

TH 731 D2/A E/NG

TH 731 D2/A E/TG

TH 931 D2/A E/LPG

TH 931 D2/A E/NG

TH 931 D2/A E/TG

Summary of Contents for TH 721 D22 B/LPG

Page 1: ...731 D2 A B LPG TH 731 D2 A B NG TH 731 D2 A B TG TH 931 D2 A B LPG TH 931 D2 A B NG TH 931 D2 A B TG TH 721 D22 E LPG TH 721 D22 E NG TH 721 D22 E TG TH 731 D2 A E LPG TH 731 D2 A E NG TH 731 D2 A E T...

Page 2: ...liance Pg3 Description of the appliance Pg3 5 Installation Pg6 12 Start up and Use Pg13 14 Precautions and tips Pg14 General safety Pg14 Assistant Pg15 Cleaning and maintenance Pg15 Practical tips Pg1...

Page 3: ...they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintena...

Page 4: ...TH 721 D22 E LPG TH 721 D22 E NG TH 721 D22 E TG TH 731 D2 A E TG TH 931 D2 A B LPG TH 931 D2 A E LPG TH 931 D2 A B NG TH 931 D2 A E NG TH 931 D2 A B TG TH 931 D2 A E TG DESCRIPTION OF THE APPLIANCE...

Page 5: ...el number Burner Variants Wok burner Semi rapid burner Total Dimensions TH 721 D22 B LPG 2 0 9kW 655g h 760 X 450 mm TH 731 D2 A B LPG 2 1 11kW 800g h 760 X 450 mm TH 931 D2 A B LPG 2 1 11kW 800g h 86...

Page 6: ...mm TH 731 D2 A E NG 2 1 10 7kW 760 X 450 mm TH 931 D2 A E NG 2 1 10 7kW 860 X 500 mm Note Wok burner Rated at 4 5kW Auxiliary burner Rated at 1 7kW Burner Injector size mm Injector marking Full rate...

Page 7: ...ed in permanently ventilated rooms in compliance with provisions laid down by current regulations and standards The following requirement must be observed A The room must be fitted with a ventilation...

Page 8: ...e outside as described above as long as the adjacent rooms are not shared areas bedrooms or present the risk of fire Fig B C Intensive and prolonged use of the appliance may necessitate supplemental v...

Page 9: ...llation of the cooker the following precautions must be taken Kitchen cabinets adjacent to the appliance and taller than the top of the cooktop must be at least 200 mm from the edge of the cooktop Hoo...

Page 10: ...p securely it is recommended that all the clamps be used TH 721 D22 B LPG TH 931 D2 A B LPG TH 721 D22 B LPG TH 931 D2 A B LPG TH 721 D22 B TG TH 931 D2 A B NG TH 731 D2 A B LPG TH 931 D2 A B TG TH 73...

Page 11: ...The dimension of the opening and the inside of the compartment shall be at least large enough to accommodate the cylinders with regulator fitted which are the most commonly used in the country The to...

Page 12: ...is regulated correctly and your appliance lasts overtime make sure that gas pressure levels comply with the indications given Nozzle and Burner Specifications Gas connection to Non flexible Pipe Coppe...

Page 13: ...ance with current installation regulations Particular attention shall be given to the relevant requirements regarding ventilation CAUTION In case of cooktop glass breakage shut immediately off all bur...

Page 14: ...all the way in and turn in the counter clockwise direction to the high setting On those models fitted with safety devices user must keep the knob press down until the burner ignites for approximately...

Page 15: ...damp hands and feet Avoid improper and or dangerous use Avoid obstructing the ventilation or heat dissipation slots The openings used for ventilation and dispersion of heat must never be covered Ensur...

Page 16: ...arts CLEANING and MAINTENANCE Before cleaning or performing maintenance disconnect the appliance from the gas supply and allow it to cool down General cleaning To extend the life of the cooktop it is...

Page 17: ...ician authorized by the manufacturer PRACTICAL TIPS Using the Burners For best performance follow these general guidelines 1 Use the appropriate cookware for each burner see table in order to prevent...

Page 18: ...parts that make up the burner are mounted correctly There are draughts around and cooking surface There are no draughts around and cooking surface The burner does not remain on when set to Low Burner...

Page 19: ...18 Electrical connection 19...

Page 20: ...19 Electrical connection models TH 721 D22 E LPG TH 721 D22 E NG TH 721 D22 E TG TH 931 D2 A E LPG TH 931 D2 A E NG TH 931 D2 A E TG TH 731 D2 A E LPG TH 731 D2 A E NG TH 731 D2 A E TG...

Reviews: