4
Pre-Installation -
continued
Installation position
A
Minimum
height from the hob surface to the underside face of the rangehood
600mm
electric hob
650mm
gas hob – from top of trivot
Notes: If the instructions for the gas hob specify a greater distance, this has to be taken into account.
Any installation above 750mm will compromise performance.
B
Vertical height from bottom of Rangehood to Fixing Plate mounting screws
323mm.
C
Distance between mounting screw holes on Fixing Plate
100mm.
A
B
C