GB
5
Burner and nozzle specifications
Table 1
Propane
Natural Gas
Burner
Diameter
(mm)
Nominal Thermal
Power
Nozzle
1/100
Nominal
Thermal Power
Nozzle
1/100
(MJ/h)*
(mm)
(MJ/h)*
(mm)
Reduced Rapid (RR)
100
9,0
80
8,3
129
Semi Rapid (S)
75
5,5
64
6,0
110
Auxiliary (A)
55
3,5
50
3,3
80
Triple Crown (TC)
130
15,0
105
15,0
175
Total Thermal Power
(MJ/h)
33,0
32,6
Supply pressures
Nominal (kPa)
Minimum (kPa)
Maximum (kPa)
2,75
2,00
3,50
1,00
0,75
1,20
* At 15°C and 101,3 kPa dry gas
Propane = 95,8 MJ/m³
Natural gas = 37,8 MJ/m³
S
A
RR
TC
PH640MT NG
PH640MST NG
PH640MT PR
PH640MST PR
Summary of Contents for PH640MST NG
Page 11: ...GB 11...