Supplied By www.heating spares.co Tel. 0161 620 6677
12
1.5.3 Removing the automatic air vent
1. Unscrew valve top “Y” (F
IG
. 1.35);
2. Remove valve complete with float (F
IG
1.36).
F
IG
. 1.35
Y
F
IG
. 1.36
1.5.2 Removing the safety valve
1. Disconnect the discharge pipe work from below the
boiler;
2. Unscrew and remove the valve “X” (F
IG
. 1.34).
F
IG
. 1.34
X
Summary of Contents for microCombi