23 MFFI

27 MFFI

27 RFFI SYSTEM

30 MFFI

CE Certification
Heat Input

max/min   kW

25.6/11.0

29.8/12.0

29.8/12.0

33.0/12.0

Heat Output

max/min   kW

23.1/9.2

27.3/10.1

27.3/10.1

30.3/10.2

Efficiency of Nominal Heat Input

%

90.2

91.6

91.6

92.0

Efficiency at 30% of Nominal Heat Input

%

87.8

88.3

88.3

88.6

Heat Loss to the Casing (³T=50°C)

%

1.2

1.3

1.3

1.4

Flue Heat Loss with Burner Operating

%

8.6

7.1

7.1

6.6

Flue Heat Loss with Burner Off

%

0.4

0.4

0.4

0.4

Maximum Discharge of Fumes (G20-G25)

Kg/h

59

62

62

61

Residual Discharge Head

mbar

1.15

1.4

1.4

1.4

Consumption at Nominal Capacity (G20-G25) m

3

/h

2.72/3.32

3.16/3.86

3.16/3.86

3.49/4.05

Gas Consumption after 10 Minutes*

m

3

0.32/0.39

0.37/0.45

0.37/0.45

0.41/0.47

(15°C, 1013 mbar) (G30-G31)

Kg/h

2.02/2.00

2.35/2.32

2.35/2.32

2.60/2.57

Temp. of exhaust fumes at nominal

capacity (G20-G25)

°C

137

128

128

135

CO

Content

%

5.8

6.6

6.6

7.5

O

Content

%

9.2

8.0

8.0

8.0

CO Content

ppm

32

34

34

49

Minimum Ambient Temperature

°C

+5

+5

+5

+5

Head Loss on Water Side (max) (³T=20°C)

mbar

200

200

200

200

Residual Head of System

bar

0.25

0.25

0.25

0.25

Heating Temperature 

max/min  °C

82/42

82/42

82/42

82/42

Domestic Hot Water Temperature

max/min  °C

56/36

56/36

---

56/36

D.H.W. Flow Rate ³T=35°C

l/min

9.5

11.2

---

12.3

D.H.W. Flow Rate ³T=35°C

gal/min

2.1

2.5

---

2.7

D.H.W. Flow Minimum Rate

l/min

2.6

2.6

---

2.6

Pressure of Domestic Hot Water

max/min bar

6/0.2

6/0.2

---

6/.02

Expansion Vessel Capacity

l

7

7

7

7

Expansion Vessel Pre-load Pressure

bar

1

1

1

1

Maximum Water Content in System

l

145

145

145

145

Maximum Heating Pressure

bar

3

3

3

3

Nominal Pressure  Natural Gas (G20-G25)

mbar

20-25

20-25

20-25

20-25

Liquid Gas   (G30-G31) mbar

30-37

30-37

30-37

30-37

Electrical Supply

V/Hz

230 / 50

230 / 50

230 / 50

230 / 560

Power Consumption

W

150

190

190

190

Protection Grade of Electrical System

IP

X4D

X4D

X4D

X4D

Internal Fuse Rating

FAST 2 AT

FAST 2 AT

FAST 2 AT

FAST 2 AT

Weight

Kg

47

47

46.5

47

G.C. Number

47-116-08

47-116-09

41-116-01

47-116-13

1.2

Technical Information

- Check the general condition of the appliance and of the combustion

chamber visually.

- Visual check of the combustion: clean burners if necessary.
- With reference to point 3, dismantle and clean the combustion chamber if

necessary.

- With reference to point 4, dismantle and clean the injectors if necessary.
- Visual check of the primary heat exchanger:

- check for overheating of the exchangers fins;
- clean the exhaust side of the exchanger and fan if necessary.

- Regulate the gas pressure, ignition pressure, partial flame, maximum flame.
- Check proper operation of the heating safety system:

- maximum safety temperature;
- maximum safety pressure.

10 - Check the proper operation of the gas safety system:

- gas or flame safety device;
- gas valve safety device.

11 - Check that the electrical connections have been made in compliance with

the instructions shown in the Installation Instructions.

12 - Check the efficiency of the hot water supply (flow and temperature).
13 - Check general operation of the appliance.
14 -  Check the exhaust system for the combustion products.

*Calculated at 70% maximum output

Summary of Contents for GENUS 27 MFFI

Page 1: ...Installation Instructions Type C Boilers G C N 41 116 01 47 116 08 47 116 09 47 116 13 LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER Country of destination GB...

Page 2: ...2 10 Room Thermostat Connection 2 11 Electrical System Diagrams 2 12 Water Circuit Diagrams 3 COMMISSIONING 3 1 Initial Preparation 3 2 Removing the Casing 3 3 Control Panel 3 4 Initial Start up 3 5...

Page 3: ...erty You will find the data plate on the reverse of the control panel The gas with which this appliance operates is also shown on the label at the bottom of the boiler Do not install this appliance in...

Page 4: ...sel Pre load Pressure bar 1 1 1 1 Maximum Water Content in System l 145 145 145 145 Maximum Heating Pressure bar 3 3 3 3 Nominal Pressure Natural Gas G20 G25 mbar 20 25 20 25 20 25 20 25 Liquid Gas G3...

Page 5: ...orised Valve RFFI 10 Main Circuit Temperature Probe 11 Main Circuit Flow Switch 12 Domestic Hot Water Temperature Probe 13 Diverter Valve Microswitch 14 Filter Seat 15 Drain Valve 16 Secondary Heat Ex...

Page 6: ...sealed appliance is installed in a room containing a bath or shower the boiler and any electrical switch or appliance control utilising mains electricity should be situated so that it cannot be touche...

Page 7: ...A B D E C 465 99 99 132 67 65 85 155 208 30 49 F G A D E C AF C DGE GENUS 23 27 30 MFFI GENUS 27 RFFI SYSTEM In order to allow for access to the interior of the boiler for maintenance purposes the boi...

Page 8: ...l as follows The yellow green wire should be connected to the terminal marked with the earth symbol make sure to re use the ferrule mounted on the other supply cord The blue wire should be connected t...

Page 9: ...uitable only for sealed systems Drain Cocks These must be located in accessible positions to permit the draining of the whole system The taps must be at least 15mm nominal size and manufactured in acc...

Page 10: ...nter and one for the summer This enables the flow rate through the appliance to be adjusted so that a sensible D H W temperature may be achieved throughout the year Domestic Water The domestic water m...

Page 11: ...terminal facing a terminal 1200 J From an opening in the car port e g door window into dwelling 1200 K Vertically from a terminal in the same wall 1500 L Horizontally from a terminal in the same wall...

Page 12: ...air vent intake located on the top part of the combustion chamber A A A Fig 2 8 This procedure must be done as follows 1 Remove the air vent intake you want to use in the area indicated in Fig 2 9 by...

Page 13: ...13 B004 In Fig 2 11 below several different types of flue systems are shown For additional information regarding the flue accessories please consult the Flue Pipe Accessories manual Fig 2 11...

Page 14: ...cated in the table 4 The exhaust pipe must extend at least 0 5 m above the ridge of the roof if it is located on a side other than that for the air intake this is not obligatory if the exhaust and air...

Page 15: ...tat these must be connected in series as per points 1 8 above Note Only a two wire type room thermostat can be used For details on fitting the D H W probe Genus 27 RFFI only please consult the separat...

Page 16: ...ection Q On Off L E D R On Off Switch S Interface Wire for P C B s T Relay Motorised Valve U Ignitor Relay V Gas Valve Relay W Fan Relay X Circulation Pump Relay Y Selector TCS2 Z Link for Continuous...

Page 17: ...17 B004 Aa GENUS 23 27 30 MFFI Aa GENUS 27 RFFI SYSTEM...

Page 18: ...18 B004 CN202 P GENUS 23 27 30 MFFI P GENUS 27 RFFI SYSTEM...

Page 19: ...cluding Safety Pressure Switch for Primary Circuit 11 Automatic By pass 12 Microswitch for Diverter Valve 13 Sensor for Domestic Hot Water 14 Secondary Heat Exchanger 15 Domestic Water Inlet Filter 16...

Page 20: ...r inlet cock supplied with the connection kit Open slowly each draw off tap and close it only when clear water free of bubbles is visible Gas Supply Inspect the entire installation including the gas m...

Page 21: ...ition Lockout L E D C Selector Knob for Summer Winter Flue Analysis Modes D Low System Water Level L E D E Temperature Adjustment Knob for Domestic Hot Water F Heating System Thermometer G Safety Over...

Page 22: ...e lines Loosen the cap on the head of the pump to eliminate any air pockets Repeat the procedure for bleeding the radiators of air Open the taps for a brief period Check the system pressure and if it...

Page 23: ...a shutdown status With a differential manometer connected to the test socket on the combustion chamber the DP value for the air pressure switch can be taken The measured value should not be less than...

Page 24: ...fety pressure switch on the primary circuit has not sensed a pressure of at least 1 bar within 40 seconds of the activation of the circulation pump it shuts off the boiler and lights the L E D D The s...

Page 25: ...5 C 1013mbar mc h 3 49 Consumption 15 C 1013mbar Kg h 2 60 2 57 Gas Cock Outlet Pressure max min mbar 11 4 1 4 4 1 5 6 25 B004 The outlet pressure of the gas cock is obtained by completely loosening t...

Page 26: ...ssembly clean the exhaust fan if needed 8 Adjustment of the flow rate of the gas flow rate for lighting partial load and full load 9 Check of the heating safety systems safety device for maximum tempe...

Page 27: ...201 6 3 E 1 2 Towerchron FP 6 1 0 2 1 Link 1 5 4 7 9 Towerchron MP 6 1 0 2 1 Link 1 4 6 11 Towerchron 2000 HW HTG N L ON ON ACL LS522 LS722 3 4 N L Randall 922 972 3 6 E N L Link L 2 5 Randall 3020 P...

Page 28: ...4 E 1 2 Link 2 3 6 Sunvic DHP 2201 6 3 E 1 2 Towerchron FP 6 10 2 1 Link 1 5 4 7 9 Towerchron MP 6 10 2 1 Link 1 4 6 11 Towerchron 2000 HW HTG N L ON ON ACL LS522 LS722 3 4 N L Randall 922 972 3 6 E N...

Page 29: ...B004 NOTES...

Page 30: ...30 B004 NOTES...

Page 31: ...31 B004...

Page 32: ...e f f f f e e RECANATI Manufacturer Merloni TermoSanitari SpA Italy Commercial subsidiary MTS GB LIMITED MTS Building Hughenden Avenue High Wycombe Bucks HP13 5FT Telephone 01494 755600 Fax 01494 459...

Reviews: