user’manual

Dear Customer,
Thank you for choosing an ARISTON boiler.

We  guarantee  that  your  boiler  is  a  reliable  and  technically  sound  product. This  manual  provides  detailed 

instructions and recommendations for proper installation, use and maintenance.

Remember to keep this manual in a safe place for future reference i.e. by the gas meter.

Your local MTS Servicing Centre is at your complete disposal for all requirements.

The  installation  and  first  ignition  of  the  boiler 

must  be  performed  by  qualified  personnel  in 

compliance  with  current  national  regulations 

regarding  installation,  and  in  conformity  with 

any requirements established by local authorities 

and public health organisations. 

After  the  boiler  has  been  installed,  the  installer 

must  ensure  that  the  end  user  receives  the 

declaration  of  conformity  and  the  operating 

manual,  and  should  provide  all  necessary 

information as to how the boiler and the safety 

devices should be handled.

This appliance is designed to produce hot water for 

domestic use. 

It  should  be  connected  to  a  heating  system  and  a 

distribution network for domestic hot water, both of 

which must be compatible with its performance and 

power levels. 

The  use  of  the  appliance  for  purposes  other  than 

those specified is strictly forbidden. The manufacturer 

cannot be held responsible for any damage caused 

by  improper,  incorrect  and  unreasonable  use  of 

the  appliance  or  by  the  failure  to  comply  with  the 

instructions given in this manual. 

Installation, maintenance and all other interventions 

must  be  carried  out  in  full  conformity  with  the 

governing  legal  regulations  and  the  instructions 

provided by the manufacturer.  Incorrect installation 

can  harm  persons,  animals  and  possessions; 

the  manufacturing  company  shall  not  be  held 

responsible for any damage caused as a result. 

In the event of any maintenance or other structural 

work  in  the  immediate  vicinity  of  the  ducts  or  flue 

gas  exhaust  devices  and  their  accessories,  switch 

the  appliance  off  by  switching  the  external  bipolar 

switch to the “OFF” position and shutting off the gas 

valve. 

When the work has been completed, ask a qualified 

technician to check the efficiency of the ducting and 

the devices. 

If the boiler should be out of use for a prolonged 

period, it is recommended that the electrical power 

supply be disconnected and that the external gas 

cock be closed. If low temperatures are expected, 

the boiler and system pipe work should be drained 

in order to prevent frost damage.

Turn the boiler off and turn the external switch “OFF” 

to clean the exterior parts of the appliance. 

Do not allow children or inexperienced persons to 

use the appliance without supervision.

CE labelling

The CE mark guarantees that the appliance conforms 

to the following directives:

90/396/CEE

  relating to gas appliances 

2004/108/CEE

  relating to electromagnetic compatibility

92/42/CEE

  relating to energy efficiency

2006/95/CEE

  relating to electrical safety

Summary of Contents for E-Combi 24

Page 1: ...ng spares co Tel 0161 620 6677 Gas fired condensing wall hung combination boilers G C N 47 116 62 24 kW G C N 47 116 63 30 kW G C N 47 116 64 38 kW E COMBI 24 E COMBI 30 E COMBI 38 Country of destinat...

Page 2: ...roper incorrect and unreasonable use of the appliance or by the failure to comply with the instructions given in this manual Installation maintenance and all other interventions must be carried out in...

Page 3: ...ns Do not perform operations which involve removing the appliance from its installation space Electrocution from live components Flooding caused by water leaking from discon nected piping Explosions f...

Page 4: ...ure is just under the minimum value re establish the correct pressure by filling loop If the pressure drops very frequently there may be a water leak at some point in the system If this is the case a...

Page 5: ...0 C to about 82 C The water temperature in the primary circuit may be checked by means of the green leds 1 Domestic hot water temperature adjustement It is possible to set the temperature of the domes...

Page 6: ...ali ed technician Important If this shutdown occurs frequently contact an authorised service centre for assistance For safety reasons the boiler will allow a maximum of 5 reset operations to take plac...

Page 7: ...r of the manu facturers guarantee Green Leds Temperature indicator Reset Note Description flashing light lit 40 50 60 70 80 90 yellow red X Overheat X Insufficient circulation Insufficient water reque...

Page 8: ...anchardstown Corporate Park 2 High Wycombe Ballycoolin Bucks HP13 5FT Dublin 15 Telephone 01494 755600 Telephone 01 810 3723 Fax 01494 459775 Fax 01 810 3727 Internet www mtsgroup com uk Internet www...

Reviews: