12
GB
RECEPTION TEST
To check the correct communication be-
tween the receiver and transmitter, power
the timer-thermostat using the batteries
provided with the kit, as described in the
relative instruction manual.
Keep the timer-thermostat at least 2-3
metres away from the receiver and per-
form the following procedure:
- Press button
.
- Press buttons “
“ together
with the PROGRAM “
“ button for
roughly 3 seconds. The display will vis-
ualise ”TRANSMISSION TEST’ and will
send the test signal to the receiver.
- The green LED on the receiver will start
fl ashing every 5 seconds for maximum
10 minutes. (During these 10 minutes
the receiver will not send any signal to
the boiler).
- Find a suitable zone in which to posi-
tion the timer-thermostat, while veri-
fying that the signal transmission is
not interrupted (green LED fl ashing).
- Press the
button to exit the TEST
mode.
NOTE:
If the red LED fl ashes on the receiver, the
transmission signal is inadequate.
Perform the receiver-transmitter recogni-
tion procedure.
LED
CAUSE
GREEN fl ashing
recognition of receiver-transmitter transmission
GREEN on
reception of transmitter signal
GREEN off
receiver ready for normal operation
RED fl ashing
receiver in re-connection mode
RED on
communication between receiver and transmitter interrupted
RED off
receiver ready for normal operation
RED LED
BUTTON
GREEN LED
Summary of Contents for Chaffoteaux 3318591
Page 56: ...56 RUS 230 50 IP30 RF 868 868 6 M 2 ETSI EN300220 1 1 3 1 2 5 2...
Page 57: ...57 RUS EU 2002 96 EC 2006 66 EC...
Page 58: ...58 RUS 30 1 2 3 3 A...
Page 60: ...60 RUS 2 3 PROGRAM 3 5 10 10...
Page 61: ...61 RUS MAN 1 1 15 0 1 0 9 5 0 5 0 5 2 3 5 0 5 0 5 4 PROGRAM InSt 5...
Page 62: ...62 GR wireless 230V 50Hz IP30 RF 868 868 6 MHz 2 ETSI EN300220 1 1 3 1 2 5 mm2...
Page 63: ...63 GR EU 2002 96 E 2006 66 EC...
Page 66: ...66 GR 2 3 PROGRAM 3 LED 5 10 10 led LED LED LED LED...
Page 86: ...86...
Page 87: ...87...