6.3.3 FUNCTIONAL COMPONENTS

Ref.

Description

Ref.

Description

001

LED PCB ARISTON05 BASIC (4 WAY)

002

SPONGE (350X8X8) “CONTROL PANEL C138-238”

003

TRIMMER KNOB ALUMINIUM-MET (C238)

004

LED INDICATOR LENS (CONTROL PANEL) R.EXT 22.7X12.4

005

ALUMINIUM BUTTON COVER-K22 (H=5.5+7.7 MM)

006

LED INDICATOR LENS (CONTROL PANEL) R.INT. 8.2X9.3

007

PROBE FIXTURE “C238”

008

AL.TAPE H50MMX50MT.X GLASS P.F (1PZ=1M)

009

LIGHT BOX (DUAL LIGHT)

010

LAMP HOLDER (VOSSLOH)250V E14 “GIUGIARO”

010

WIRING-AMP FRIDGE LAMP

011

LAMP 220-240V/15W (E14)

012

LAMP COVER (MAX 15W) COLOUR 44

013

FAN MOTOR SUPPORT-AIR (PW)

014

RUBBER STOP FAN MOTOR “NO-FROST”

015

FAN UNIT C09R1907 220V 3.5W (FATON)

016

FAN MOTOR SUPPORT-AIR (COMPL) PW

017

COVER MOTOR TURBOCOOLING “ARISTON”

018

RIGHT FIXTURE EVAPORATOR “C138 IND00”

019

LEFT FIXTURE EVAPORATOR “C138 IND00”

020

WHITE PROFILE L=443.5 MM “FIX.EVAP”

021

FREEZ.EVAP.CONDENSER L407X473(10PIROUND

022

EEPROM COMBY2005 SW 28347950000 ST-STRIP

023

FULL POWER BOARD WITHOUT EEPROM

024

COMPRESSOR WIRING

025

SOLEVNOID VALVE WIRING EV1

026

SOLENOID VALVE WIRING (EV2)

027

MODULE HOLDER-SMD

028

MODULE HOLDER COVER-SMD

029

SERIAL PLUG

030

RUNNING CONDENSER 4MF (ATT.RAP.8MM)

032

POWER CORD.3X0.75 EU MM 2500

033

COMPRESSOR CROSSPIECE 586X110 MM ASSEMBLY

034

COMPR. HTK95AA 220-240/50 1/5HP-167W R60

035

RUBBER DAMPER “EMBRACO EM-PW-FF”

036

COMPRESSOR FIXING PLATE (750908)

037

LOKRING PIPE WITH VALVE (6 NFMSSV)

038

CONDENSATION COLLECTION TAB 209X175X58 (POLAND)

039

3-WAY SOLENOID BITRON 220/50 R134-R600

040

3-WAY SOLENOID BITRON 220/50 R134-R600

041

SOLENOID VALVE FIX.BRACKET

042

FILTER GR.12 (D.4.8/D.3.2 MM) GAS R600A

043

CONDENSER 576X1000x48 (R600)

044

WALL MOUNTED SPACER X CONDENSER “IND.00”

045

POWER CORD HOOK 

099

PROBES 6 WAY CONNECTOR (AMP) KIT

099

PROBES 4-WAY CONNECTOR (AMP) KIT

Summary of Contents for 60 cm

Page 1: ...ll the parts included in this document are the property of Indesit Company S p A All rights reserved This document and all the information contained in it are supplied without responsibility for possi...

Page 2: ...ing document for technical personnel It contains a description of the various product types the general operating principles and indications concerning assistance Technical personnel should in any cas...

Page 3: ...nation of setting and operation of TOUCH control interfaces 11 14 Product characteristics 15 Static appliances 16 Full No Frost appliances 17 3 COMPONENTS 18 4 WIRING DIAGRAMS 19 22 Electronic thermos...

Page 4: ...IANCES LEGEND M B T 20 2 2 CZ M Ariston B Combi T Double Door M Mechanic L LED Ele Air T TOUCH Ele Air P BUTTONS Ele Air 15 150cm 17 175 cm 18 187cm 20 200cm 3 A 2 A Freezer Temp 1 A 1 White 2 Stainle...

Page 5: ...n 7 FREEZER knob Interface Everfresh Interface without Everfresh Legend 1 ON OFF button 2 VARIABLE TEMPERATURE COMPARTMENT temperature selector 3 FREEZER COMPARTMENT temperature selector 4 FRIDGE COMP...

Page 6: ...EN 6 Service Manual NEW ARISTON 60 cm PLATFORM Edition 2006 06 15 Language English P RODUCT T YPE 1 3 ENERGY LABEL Energy Label for appliances Ariston XXX...

Page 7: ...DUCT TYPE 2 1 ARISTON DOUBLE DOOR 2 2 ARISTON COMBI ELECTRONIC THERMOSTAT ELECTRONIC THERMOSTAT Consult Indesit New Cold Platform Manual Operation is identical or similar to equivalent Indesit applian...

Page 8: ...he freezer compartment are inter dependent since both are adjusted with the same control knob The first half of the knob s range activates the variable temperature compartment C C Z and the freezer co...

Page 9: ...ady This function operates with the same logic as appliances in the Indesit New Electronic Cold Platform consult manual The function is deactivated automatically when the maximum time has elapsed 24 h...

Page 10: ...will automatically deactivate it The function cannot be activated if the Holiday function is already active In other models with control knob interface where available this button is also used to acti...

Page 11: ...off 2 4 2 SWITCHING THE FRIDGE COMPARTMENT ON OFF The fridge compartment switches on automatically when the appliance is switched on see previous paragraph The refrigerator compartment can be switche...

Page 12: ...are as follows a STRAWBERRY symbol for a temperature of 8 C b ICE CREAM symbol maintains the C C Z temperature at approx 12 C and 3 BOTTLE symbol for a temperature of approx 18 C 4 All leds switch off...

Page 13: ...nce shows LO CH on the display for the time parameterised in the EEPROM memory while the function remains active The function is deactivated by pressing the Alarm button again for two seconds The buzz...

Page 14: ...witches on the vacuum pump The function is deactivated automatically when the PCB receives Feed Back from the vacuum switch indicating that air has been removed from the container or by pressing the E...

Page 15: ...ugh the multiflow column This grading occurs when the user selects any function other than I CARE or Super Fridge and therefore the SURROUND system is not activated c Open 90 In this case the SURROUND...

Page 16: ...to two all electronically controlled as follows E V 1 ON E V 2 Off Capillary 1 The gas is sent first to the fridge evaporator and then to the freezer evaporator as in traditional models E V 1 Off E V...

Page 17: ...WBERRY 12 C represented by an ICE CREAM and 18 C represented by a BOTTLE In the case of defrosting there is a pre defrosting procedure when the fan is activated and the damper is opened for a period o...

Page 18: ...ervice Manual NEW ARISTON 60 cm PLATFORM Edition 2006 06 15 Language English C OMPONENTS 3 COMPONENTS ELECTRONIC THERMOSTAT NO FROST COMBI Damper Variable temperature compartment separator panel Displ...

Page 19: ...1 W3 W4 W2 CO RH VZ R1 R2 TF PT LR IF S W1 TP C AC 4 WIRING DIAGRAMS Legend AC Power supply CO Compressor PT Starter relay C Running condenser where fitted RH Klixon thermoprotector VZ NF freezer fan...

Page 20: ...hermo fuse B Thermoprotector C Evaporator element D Drip tray element E Freezer fan Wiring Diagram Double Door No Frost A Thermo fuse B Thermoprotector C Evaporator element D Drip tray element E Freez...

Page 21: ...Variable temperature compartment damper on off switch J7 pin 1 3 power supply 100V pin 4 5 open close reed limit switch PV Vacuum pump D2 Stepper damper 12V signal not measurable S Serial line UI Inte...

Page 22: ...Frost A Thermo fuse B Thermo fuse C Evaporator element D Drip tray element E Freezer fan CONNECTIONS STATIC CCZ TOUCH STATIC CCZ UI LED NO FROST CCZ EF TOUCH NO FROST EF UI LED J 1 YES YES YES YES J...

Page 23: ...at the same time for six seconds The fridge and freezer displays will show dEon and the Buzzer will beep To deactivate and return to normal operation press the same buttons I CARE HOLIDAY for three se...

Page 24: ...erised for the autotest or it can be terminated by the user by switching on the appliance using the freezer knob or by disconnecting and reconnecting the mains power supply The buzzer emits a beep to...

Page 25: ...st procedure 255 seconds Test sequence The probes are tested for the first 5 seconds 10 seconds after Autotest activation the freezer fan and defrost elements switch on and remain in operation until t...

Page 26: ...n and runs until the end of the procedure Fault signalling Any faults are signalled on the fridge and freezer displays e g F01 In the event of Probe faults the fridge lamp will also flash Model COMBI...

Page 27: ...ble the LEDs stay on while the fault lasts Table Led Faults Blocking Faults Non blocking Faults Faults Signal LED 1 LED 2 LED 3 F01 off Flashing off F02 on Flashing off F03 off Flashing on F04 on Flas...

Page 28: ...ents and possible short circuits on the freezer compartment wiring junction box Renew heating element Renew PCB Check efficiency of contacts on connector J6 on the PCB Check for continuity of the defr...

Page 29: ...connector Check continuity of connector J13 connector inside cabinet control panel Check continuity of connector inside cabinet control panel interface PCB 4 way connector Renew main PCB Renew displa...

Page 30: ...it with your hand where possible and checking the change in the impedance value Renew main PCB Check efficiency of contacts on connector J12 on the PCB Check NTC probe ensuring that the impedance val...

Page 31: ...on collection bowl ruptured Water drain tube incorrectly positioned Condensation collection bowl not in contact with compressor Compressor fails to stop Faulty thermostat Incorrectly positioned thermo...

Page 32: ...ving the Display PCB 1 Attach some adhesive tape to the bottom of the PCB to prevent damage to the panel 2 Using a screwdriver prise the PCB off at the bottom on each side 3 Remove the surround carefu...

Page 33: ...nents of the Variable Temperature Compartment 1 Remove the drawers from the freezer compartment 2 Release the screws of the shelf of the variable temperature compartment 3 Remove the shelf 4 Release t...

Page 34: ...ARISTON 60 cm PLATFORM Edition 2006 06 15 Language English A SSISTANCE Removing components of the Variable Temperature Compartment 1 Release the screws of the shelf of the variable temperature compar...

Page 35: ...UNNER CHILLER LT POLARW 370X200 016 CHILLER FRONT LIGHT GREEN PW 480X123X30 017 POLARW FRIDGE SEPARATOR PANEL 497X295X22 018 CRISPER COVER PROFILE PW 504X93 PINS 6 5MM 019 RUBBER SHEET COVER PW 019 GL...

Page 36: ...PW LIGHT GREEN 361X83 010 BUTTER DISH 152X50X93 KIT 013 BOTTLE RETAINER PROFILE POLARW L 452X63 014 BOTTLE HOLDER DOOR TRAY 500X183 GLASS PW 015 DOOR CLOSURE BUSHING RT GREY 40 60219 015 DOOR CLOSURE...

Page 37: ...FIX BRACKET 006 3 WAY SOLENOID BITRON 220 50 R134 R600 007 3 WAY SOLENOID BITRON 220 50 R134 R600 008 RUNNING CONDENSER 4MF ATT RAP 8MM 010 POWER CORD 3X0 75 EU MM 2500 011 COMPRESSOR CROSSPIECE 586X...

Page 38: ...F 1PZ 1M 009 LIGHT BOX LIGHT XTRA 010 LAMP HOLDER VOSSLOH 250V E14 GIUGIARO 010 WIRING AMP FRIDGE LAMP 011 LAMP 220 240V 15W E14 012 LAMP COVER MAX 15W COLOUR 44 013 FAN MOTOR SUPPORT AIR PW 014 RUBBE...

Page 39: ...CUUM ELBOW SEAL CROSS 013 RUNNER BUSHING PW CHILLER 014 DRAWER RUNNER CHILLER LT POLARW 370X200 015 DRAWER RUNNER CHILLER RT POLARW 370X200 016 FRIDGE SEPARATOR PANEL POLARW 497X282X30 017 CRISPER COV...

Page 40: ...8 INTERM DOOR TRAY 500X44X111 GLASS PW 009 CAN HOLDER PW LIGHT GREEN 361X83 010 BUTTER DISH 152X50X93 KIT 011 BOTTLE RETAINER PROFILE POLARW L 423X39 012 BOTTLE HOLDER DOOR TRAY 500X104 GLASS PW 015 D...

Page 41: ...60 010 CONTROL PANEL COVER 74X20 CABINET POLAR WHI 011 ADHESIVE SPONGE L 500X12 011 ADHESIVE SPONGE L 1300x12x5 012 FREEZER BASE KIT PW NF 401X530 023 VACUUM PUMP SUPPORT 024 VACUUM PUMP ASSEMBLY 025...

Page 42: ...TURE C238 017 CONDENSER FIXING PLATE 018 RUNNING CONDENSER 4MF pin M8 018 RUNNING CONDENSER 4MF 8MM ROHS 019 POWER CORD 3X0 75 EU MM 2500 020 ADHESIVE SPONGE L 500X12 022 THERM DAMPER FBZ118F 1W AC100...

Page 43: ...4 GLASS PROFILE CRISPER 504X78X9 POLARW 015 WHITE CRISPER LXH 240X146X326 IND4 016 CLEAR CRISPER FRONT 240X159X30 017 SUPER DRAWER POLARW LXP 434X394x123 018 SUP DRAWER FRONT 429X155 GLASS PW 019 ADHE...

Page 44: ...PW LIGHT GREEN 361X83 011 BOTTLE RETAINER PROFILE POLARW L 423X39 012 BOTTLE HOLDER DOOR TRAY 500X104 GLASS PW 013 DOOR CLOSURE BUSHING RT GREY 40 60219 013 DOOR CLOSURE BUSHING LT GREY 40 60219 013...

Page 45: ...TURE EVAPORATOR C138 IND00 019 LEFT FIXTURE EVAPORATOR C138 IND00 020 WHITE PROFILE L 443 5 MM FIX EVAP 021 FREEZ EVAP CONDENSER L407X473 10PIPELINES ROUND 022 EEPROM COMBY2005 SW 28347950000 ST STRIP...

Page 46: ...11 58122 21121 10 55045 94375 9 52150 54393 8 49424 39237 7 46856 67575 6 44437 32697 5 42156 97006 4 40006 86932 3 37978 88256 2 36065 41784 1 34259 39368 0 32554 20227 Temperatures deg C Impedance...

Page 47: ...Manual NEW ARISTON 60 cm PLATFORM Edition 2006 06 15 Language English Indesit Company viale Aristide Merloni 47 60044 Fabriano Italy tel 39 0732 66 11 telex 560196 fax 39 0732 66 2954 www indesitcomp...