11
1. 5. 2 Removing the safety valve
1. Loosen nut “Y” (F
IG
. 1.33);
2. Disconnect the discharge pipe work from below the
boiler;
3. Unscrew and remove the valve.
1.5.3 Removing the automatic air vent
1. Unscrew valve top “Z” (F
IG
. 1.34);
2. Remove valve complete with float (F
IG
1.35).
F
IG
. 1.33
F
IG
. 1.34
Y
Z
F
IG
. 1.35
Important! Before any component is removed, the boiler
must be drained of all water.
1.5
A
CCESS TO THE
W
ATER
C
IRCUIT
F
IG
. 1.31
W
F
IG
. 1.32
X
1.5.1 Removing the pump pressure switch
1. Remove the cable of the pump pressure switch “W”
(Fig. 1.31);
2. Unscrew the pump pressure switch by using a spanner
on the nut “X”(F
IG
. 1.32);
3. Remove the pump pressure switch.