Internal Unit electrical connection

Before any operation on the system, turn off  the main power. Observe 
the phase and neutral connections.
To access the control panel of the internal unit, proceed as follows: Re-
move the three screws (A) indicated in fi gure and remove the cover of 
the electrical panel (B).

When opening the internal unit, you will fi nd the following 
connections:
ANODE -   Tank Protech anode connection.
 

 

Observe the electrical polarities.

TA1 

-  Ambient contact thermostat connection, zone 1. 

TA2 

-  Ambient contact thermostat connection, zone 2.

SE 

-  Outdoor temperature sensor connection.

TNK 

-  Tank sensor connection.

BUF - 

Buff er sensor connection.

BUS 

-  BUS connection for System interface and

 

 

BUS connection between internal and external unit.

IN-AUX -   Humidistat/auxiliary input connection.
HV IN 3 -  230V Input. Select the operation mode by the parameter  
  

17.1.2.

PV Integration: through this input is possible to use the DHW  
tank as energy storage in case of a surplus of energy produc-
tion by a PV system. Connect the output contact from an energy 
meter to the PV input, the output contact is closed when the 
energy production is higher than a threshold settable on the 
energy meter.

HV IN 1 -  230V Input. Select the operation mode by the parameter  
 17.1.0. 

•EDF (Night tariff ): applying a 230V signal to the input  the tank 

charge is enabled according to the DHW modes HC-HP or 
HC-HP 40°C selectable by the parameter 17.5.2

•SG Ready 1: input signal nr 1 for the SG Ready standard (see 

paragraph SMART GRID READY STANDARD).

HV IN 2 -  230V Input. Select the operation mode by the parameter  
 17.1.1.

•DLSG (load shedding): this input signal, if supplied by the elec-

trical grid provider, disable the heating resitors. 

•SG Ready 2: input signal nr 2 for the SG Ready standard (see 

paragraph SMART GRID READY STANDARD).

OUT-AUX  1- 

Auxiliary output, free potential contact

 

 

(see parameter 17.1.4)

ST1 

-  Safety thermostat connection (230 V)

 

 

for under-fl oor system (shunt connection).

PM AUX-  Auxiliary pump connection. 
V1 

-  Diverter valve connection for domestic water circuit

V 2 

-  Diverter valve connection for cooling circuit

L 1 

-  Three-phase power phase 1 connection (230 V)

 

 

for internal unit  

L 2 

-  Three-phase power phase 2 connection (230 V)

 

 

for internal unit   

L 3 

-  Three-phase power phase 3 connection (230 V)

 

 

for internal unit    

-  Connection of the neutral point (230 V) of the internal unit .

  

-  Earth connection of the internal unit .

The size and length of the cables must be sized according to the 
power indicated on the data plate of the internal unit.
Ensure that the power cables are properly tightened in order to 
avoid overheating.

WARNING
After carrying out the connections between the indoor and 
outdoor units, put back both panels of the respective units.

Low voltage terminal block of 
internal unit

High voltage terminal block of 
internal unit

Power supply terminal 
block of internal unit

Summary of Contents for NIMBUS POCKET M NET

Page 1: ...IT NIMBUS POCKET M NET ISTRUZIONI TECNICHE PER L INSTALLAZIONE E LA MANUTENZIONE TECHNICAL INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE OK 420000454000 3319105 ...

Page 2: ...nd frequency of power supply from the network coincide with the data shown in the data plate of the appliance see table In order to ensure greater security the main electrical system should be checked by a qualified technician before proceeding with the installation see note The manufacturer is not liable for any damage caused by installation with improper grounding or abnormalities in the electri...

Page 3: ... not be in contact with the compressor and the hot pipes To ensure good tensile strength the electric cables must be fastened using the cable holder on the plate C Connect the communication cable to the terminals as identified by their respective numbers on the terminal block of indoor and outdoor unit According to the installation instructions all devices for disconnection from the power supply ma...

Page 4: ...ight tariff applying a 230V signal to the input the tank charge is enabled according to the DHW modes HC HP or HC HP 40 C selectable by the parameter 17 5 2 SG Ready 1 input signal nr 1 for the SG Ready standard see paragraph SMART GRID READY STANDARD HV IN 2 230V Input Select the operation mode by the parameter 17 1 1 DLSG load shedding this input signal if supplied by the elec trical grid provid...

Page 5: ...or and outdoor unit put back both panels of the respective units Electrical connections between internal and external unit Before any work on the system shut off the power at the breaker NOTE It is strongly recommended to verify the presence of a surge protection device SPD on main power line and of circuit breakers connected to the external and internal unit s control box See table of electrical ...

Page 6: ...61 GB 3 ph 1 ph ELECTRICAL SCHEME BOX OF EXTERNAL UNIT ...

Page 7: ...N5 CN14 CN2 CN8 EBUS EBUS C35 PUMP 2 CN10 CN16 CN12 CN11 F1 1 1 1 1 4 3 1 6 1 1 1 1 1 1 1 ENERGY MANAGER RD RD BK BN GN GN GY GY RD RD BU BU BU OR BK YE YE BN BU BN BN BN BN BU BU BN BU BN BU BU YE GN YE GN YE GN YE GN YE GN RD GN GY YE PI YE GN L N ANODE SE TNK BUF BUS TA 1 TA 2 B T IN AUX1 24V BN BU BN BU BK Black BN Brown BU Blue RD Red OR Orange YE Yellow GN Green GY Grey WH White PI Pink ...

Page 8: ...420010851000 08 2017 Ariston Thermo SpA Viale Aristide Merloni 45 60044 Fabriano AN Italy Telefono 0732 6011 Fax 0732 602331 info it aristonthermo com ...

Reviews: