Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 39 di 64
4.3.2.5 Setting the ignition burner pressure gas
IGNITION BURNER PRESSURE (mbar)
G20
G30
G31
11 L
7,0
10,8
18,8
14 L
7,0
15,4
23,4
b
a
1. Inlet pressure gas:
a
2. Pressure gas on the burner
:b
3. Open the sanitary tap.
4. Put the
Switch 1
on ON :
Test
Mode.
5. Put the
Switch 2
/
Switch 3
OFF :
Mini Power.
6. Setting the
Orange screw
(see the table).
7. Put the
Switch 1
on OFF :
to exit the mode test.
8. To save the gas setting remove the batteries.
b
a
1. Inlet pressure gas:
a
2. Pressure gas on the burner:
b
3. Open the sanitary tap.
4. Put the
Switch 1
on ON :
Test
Mode.
5. Put the
Switch 2
ON and
Switch 3
ON :
Ignition
Power.
6. Setting the
Orange screw
(see the table).
7. Put the
Switch 1
on OFF :
to exit the mode test.
8. To save the gas setting remove the batteries.
Summary of Contents for BRD LNX
Page 44: ...Training Manual FAST EVO X FLUENDO PLUS LNX FAST EVO R X BRD LNX Page 44 di 64 ...
Page 62: ...Training Manual FAST EVO X FLUENDO PLUS LNX FAST EVO R X BRD LNX Page 62 di 64 ...
Page 63: ...Training Manual FAST EVO X FLUENDO PLUS LNX FAST EVO R X BRD LNX Page 63 di 64 ...
Page 64: ...Training Manual FAST EVO X FLUENDO PLUS LNX FAST EVO R X BRD LNX Page 64 di 64 ...