background image

 

System Installation Manual

 

DV-96

 

Digital Keyphone Wiring for D2DLUA, D2HYUA and D2SLUA 

 

 

4 Wires 

Phone Box

D2DLUA 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 21. Digital Key Station Wiring on D2DLUA 

 

 

1.  (ST1)~(ST8) are all for the Digit Key Telephone connections. 

2.  BT/BR is the Data/Audio/Power pair

no polarity

 

 

 

 

 

 

 

 

40 

Arista Systems Corporation 

Summary of Contents for DV-96

Page 1: ...th the actual installation The National Electrical Code NEC requires the local telephone company Telecom to provide the primary protection devices for the telephone lines terminating at the customer s site Make sure that a primary protection device has indeed been installed by the Telecom If no such device is present notify the Telecom before installing your Aristel system 1 Arista Systems Corpora...

Page 2: ...ntelligent Digital Key Telephone System has the listed capacities trunk card basic 4 lines per card maximum 4 cards 16 ports and 16 64 extension ports It can also be equipped with the following system peripherals SMDR interface Door Phone Interface Multi Function Sensor Interface Multi Function Relay Remote Programming Interface External Music Interface External paging interface Voice Mail and Aut...

Page 3: ...System Installation Manual DV 96 Aristel DV 96 Digital Intelligent Key Phone System Multiple Processors Time Division Multiplexing Unique ARISTEL ASIC Chip A SERIES 3 Arista Systems Corporation ...

Page 4: ... Single Line Phone 2 64 66 Auto Attendant 0 4 0 4 0 Voice Mail 0 0 4 0 4 Voice Service interface Recording Extension 0 26 26 Door Phone interface 0 2 2 Relay Switches 0 2 2 Sensor 0 2 2 Fax Monitor 1 3 4 RS232 For SMDR 0 1 1 Remote Programming 0 1 1 UPS interface 1 0 1 Speed Dial 1000 sets 0 1000 sets Caller ID card 0 16 16 Power Failure Transfer Phone 1 3 4 External Music 1 0 1 External Paging 0 ...

Page 5: ... Call Hands Free Internal External Direct Dial Photo Interrupt Hook Switch Digital Volume Control 8 Levels 8 Levels 8 Levels 8 Levels 8 Levels 8 Levels 8 Levels 8 Levels OHCA Function One Touch Paging Last Number Redial Name Speed Dial Calculator Individual Speed Dial Difference Ringing Frequencies Dual Color Tri Status LED 8 keys 8 keys 8 keys 8 keys 16 keys 16 keys 16 keys 16 keys One Digit Auto...

Page 6: ... of 16 single line station ports Expansion Card D2HYUA Hybrid Station Unit Consisting of 2 digital key station ports plus 12 single line station ports Expansion Card D1RSCC RS232 Card Providing 1 RS232 port and working for SMDR Optional Card D1VSCA Voice Service Card Consisting of 2 Voice Channels 60 sec per channel for Auto Attendant applications Optional Card D1VSCB Voice Service Expansion Card ...

Page 7: ...ion site should have sufficient room to mount the KSU along with the necessary connecting blocks and ancillary equipment on a wall The installation site should not be in areas subject to static electricity e g Dry copiers or vibration e g Heavy machinery A dedicated earthed power outlet for the KSU either 240VAC 50Hz or 110VAC 60Hz and a 10 Amp circuit are required An integral earth is required in...

Page 8: ...d against equipment ordered to ensure that ALL components have been received The following materials are required not provided for installation Exterior grade plywood backs board for the KSU 1 Male Tail per extension board for Station wiring Two pair or Three pair for OHCA Station twisted station cable Appropriate mounting hardware 8 Arista Systems Corporation ...

Page 9: ...rotector should be installed at the dedicated AC outlet Connect Male Tail and connect the plug to each station board for station wiring also connect the wire to the RJ 11 for connector on each trunk card for the CO lines wiring Plug in the power cord of the power supply to an AC Power Outlet and then turn on the power of the system 9 Arista Systems Corporation ...

Page 10: ... LAYOUT D2PWUA D2DLUA D2SLUA D2HYUA D1TKUC D1DTKA D1DTKB 3 4 2 1 D1SLCB D2MBUB D1VSCA D1VMCA D1RPCA D1RSCC D1MFCA 5 1 AC Power Inlet 2 AC Power Switch 3 Power Indicator LED Type 4 DC Power Switch 5 RS232 Female DB9 for the connection to the D1RSCC 10 Arista Systems Corporation ...

Page 11: ... mm x 130 mm Function 1 The motherboard control entire system functions and audio switching 2 Motherboard supports External Music Source Input Terminal 3 System programming Auto Protection by Li Battery 18 1 10 20 3 19 11 2 4 The Installation Site of D2MBUB 7 14 8 17 9 16 6 12 5 15 11 Arista Systems Corporation ...

Page 12: ...MOH application 9 MFC 13P 2 Wafer Connector for D1MFCA connection 10 SLC 13P 2 Wafer Connector for D1SLCB connection 11 DTA1 4 30P 2 Header Connector for D2SLUA D2HYUA and D2DLUA connection 12 ASIC Aristel proprietary ASIC 13 LCD Additional LCD connector for engineering system maintenance 14 JP1 3Pins Wafer Jumper to turn ON OFF Li battery power 15 TKU1 4 25P 2 Header Connector for both D1TKUC and...

Page 13: ...or external Back up Battery The Installation Site of D2PWUA 7 8 5 1 4 6 2 3 1 LED501 Power Indicator 2 SW101 AC Power Switch 3 CN101 AC Power Inlet 4 CN802 4 Pins Connector for D2MBUB connection 5 SW401 External backup battery Power Switch 6 CN105 Protection Earth Terminal for D1SLCB Grounding 7 CN402 External Battery Connector Left Side is Right side is 8 CN301 6 Pins Connector for D2MBUB connect...

Page 14: ...t either D1CIDC FSK DTMF CLI interface or D1MDCA Meter Pulse Detection Card connections on each CO line 1 2 3 4 The Installation Site of D1TKUC 1 CN1 60 Wires rainbow Cable to connect to TKU1 4 positions where upon the D2MBUB 2 CN3 The socket for both Power Failure standard Phone and FAX connections 3 CN2 The RJ socket for POTS CO lines connections 14 Arista Systems Corporation 4 CH1A 4A and CH1B ...

Page 15: ...lity 8 lines for 2B D or 16 lines for Voice channel 3 1 2 4 7 8 9 5 6 The Installation Site of D1DTKA 1 Test Connector for engineer testing 2 Test Connector for engineer testing 3 Flat cable connect to D1MBUB 4 RJ 45 connector to connect to ISDN BRI Line 5 JP1 jumper for first line line termination enable disable 6 JP2 jumper for second line line termination enable disable 7 JP3 jumper for DTKA ca...

Page 16: ...n off hook JP1 Short line termination enable default N C line termination disable JP2 Short line termination enable default N C line termination disable JP3 please see below table for reference 0 1 Slot number of TKU Short Short 1 N C Short 2 Short N C 3 N C N C 4 16 Arista Systems Corporation ...

Page 17: ...6 ISDN TRUNK UNIT Item D1DTKB ISDN PRI CARD Size 162 mm x 122 mm Function 1 Supports 1 lines of 30B D interface which support 30 voice channels 2 Maximum one card install per system when install D1DTKB system cannot support D1DTKA as same time 17 Arista Systems Corporation ...

Page 18: ...led onto the DV 96 main frame 64 Extensions Maximum 3 D2DLUA is fully compatible with DV Series Key Telephones Ex DKP 30 DKP 31 DKP 32 DKP 33 DKP 50 DKP 51 DKP 52 DKP 53 3 4 2 1 The Installation Site of D2DLUA 1 Flat cable connector to D2MBUB STA1 4 slots 2 Centronic connector for WP5007 cable wiring 3 Reset Button to Reset the D2DLUA on board micro controller 4 LED Red for Power indication and on...

Page 19: ...LT Station Ports 2 Totally 4 pieces of D2SLUA could be installed onto the DV 96 main frame 64 SLT Maximum 3 4 2 1 The Installation Site of D2SLUA 1 Flat cable connector to D2MBUB STA1 4 slots 2 Centronic connector for WP5007 cable wiring 3 Reset button to reset the D2SLUA on board micro controller 4 LED Red for Power indication and on board micro controller 19 Arista Systems Corporation ...

Page 20: ...lus 12 SLT Stations Ports 2 Totally 4 pieces of D2HYUA could be installed onto the DV 96 main frame 3 Digital Key Station ports fully compatible with DV Series Key Telephones Ex DKP 30 DKP 31 DKP 32 DKP 33 DKP 50 DKP 51 DKP 52 DKP 53 4 Single line station can be connected to SLT ports EX SLT Modem Wireless Phone 3 4 2 1 The Installation Site of D2HYUA 20 Arista Systems Corporation ...

Page 21: ...ble connector to D2MBUB STA1 4 slots 2 Centronic connector for WP5007 cable wiring 3 Reset button to reset the D2HYUA on board micro controller 4 LED Red for power indication and on board micro controller activity 21 Arista Systems Corporation ...

Page 22: ...ial socket instead of occupying Extension ports socket 2 All of single line station can be connected to SLT ports EX SLT Modem Wireless Phone 2 The Installation Site of D1SLCB 3 1 1 CN1_B 6 Pins Wafer Connector for both Single Line Telephone Ports connections 2 SLC Wafer Connector to connect to SLC Position where upon the D2MBUB 3 FG Green Yellow wire to connects to D2PWUA protection earth termina...

Page 23: ...inSM applications 1 2 3 4 5 6 The Installation Site of D1RSCC 1 CN 10 Pins Male Wafer Connector Connect to the position of Point 9 in Figure 1 by the special DB9 Cable FD 10 9 400 Male Type for the connection of either PC COM Port or Serial Printer 2 RSC 26 Pins Connector to connect to RSC position where upon the D1MBUB 3 Jumper Setting 2 1 JP4 3 Pins Jumper Selection SYS PC JP4 Receive 23 Arista ...

Page 24: ...it SYS Serial Printer 3 2 JP3 3 Pins Jumper Selection Receive Transmit 2 2 JP2 3 Pins Jumper Selection JP2 P SYS PC P PC COM Port SYS Serial Printer Transmit JP2 甲 JP1 3 Pins Jumper Selection SYS PC JP1 Receive JP1 24 Arista Systems Corporation ...

Page 25: ...IN2 SHORTED JP2 JP3 JP1 JP4 B If the system s RS232 is connected to Serial Printer please make ALL jumpers to be PIN2 PIN3 SHORTED JP2 JP3 JP1 JP4 C Note Some serial printers have already changes the TX Rx DTR DSR mode If those didn t change the system of mini jumper must change to pin1 pin2 25 Arista Systems Corporation ...

Page 26: ... space in each 2 Each channel could be pre recorded the voice for Auto Attendant and Emergence Call applications 1 2 3 The Installation Site of D1VSCA B 4 1 VSC 26 Pin Connector to connect to VSC position where upon D2MBUB 2 Expansion Connector for D1VSCB connection 3 Variable Resistors To adjust the Playing Volume of each voice channel 4 The expansion Connector to connect both D1VSCA and D1VSCB f...

Page 27: ... 2 ports of Door Phone interface 2 ports multi function Relay Switch 2 Ports of Multifunction Sensor interface 2 ports of External Paging interface 2 Multi function card is an important interface of communicating others related products in our DV 96 ex Sensor Control Relay Control External Paging Fire Alarm and Emergency Alarm Etc 5 The Installation Site of D1MFCA 4 3 2 1 27 Arista Systems Corpora...

Page 28: ... Connector for External Page Connection 4 DOOR2 Terminal Block Connector for the 2nd Door Phone Connection 5 DOOR1 Terminal Block Connector for the 1st Door Phone Connection 6 SW2 Terminal Block Connector for the 2nd Relay Connection 7 SW1 Terminal Block Connector For the 1st Relay Connection 8 AUX The Connector to connect MFC position where upon the D1MBUB 28 Arista Systems Corporation ...

Page 29: ...D1MDCA Size 91 mm x 21 mm Function Provide signal channel of the POTS CO line 12 16KHz Metering Pulse detection 1 2 The Installation Site of D1MDCA 1 CN2 To connect to the position CH1 4B where upon the D1TKUC 2 CN1 To connect to the position CH1 4A where upon the D1TKUC 29 Arista Systems Corporation ...

Page 30: ...ize 91 mm x 21 mm Function Provide signal channel of the POTS CO line DTMF FSK Calling Line Identification detection 1 2 The Installation Site of D1CIDC 1 CN2 To connect to the CH1 4B position where upon the D1TKUC 2 CN1 To connect to the CH1 4A position where upon the D1TKUC 30 Arista Systems Corporation ...

Page 31: ...EMOTE PROGRAMING CARD Item D1RPCA Size 70 5 mm x 69 mm Function 1 Standard 2400bps Modem 2 Cooperate with Aristel s Win SM for system remote programming and Maintenance 1 RPC 26 Pin Connector to connect to RPC position where upon the D2MBUB 1 The Installation Site of D1RPCA 31 Arista Systems Corporation ...

Page 32: ...basic Voice mail on board and could be expanded up to 4 ports by D1VMEA 2 On board Flash memory chip to stores the voice message 3 The Installation Site of D1VMCA 2 1 1 Expansion Flash Memory for D1VMCA 2 Expansion Voice Mail Port for D1VMCA 3 Flat cable connector to connect to the VSC position where upon the D2MBUB 32 Arista Systems Corporation ...

Page 33: ... 41 mm x 41 mm Function 1 Signal channel of Voice Mail for port expansion where upon the designated socket 2 Basic 2 channels on one board Maximum capability can be expanded to 4 channels The Installation Site of D1VMEA 1 1 Connect to the DSP3A DSP4A and DSP3B DSP4B positions where upon the D1VMCA 33 Arista Systems Corporation ...

Page 34: ...nction 1 Each Expansion Flash Memory Card provides 8 hours memory space 2 6 hours basic capacity on the D1VMCA 3 expansion flash memory cards could expand the memory up to 30 hours Maximum 6 24 30 hours 1 The Installation Site of D1VMFA 1 Connect to the F2A F5A and F3B F5B positions where upon the D1VMCA 34 Arista Systems Corporation ...

Page 35: ...System Installation Manual DV 96 INSTALLATION AND WIRING AC POWER AND DC BATTERY BACK UP INSTALLATION 35 Arista Systems Corporation Figure 18 AC Power and DC Battery Back Up Installation ...

Page 36: ...o the system can be either 115VAC or 230VAC The system can detect the input voltage automatically CAUTION There are Hazardous voltages present in the Power Supply We recommend that the Power be switched off before opening any 36 Arista Systems Corporation ...

Page 37: ...N Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions 2 Music source selection and volume control for both MOH and BGM 2 1 JP2 Music Source Selection 2 2 VR1 Volume Control External Music Source Internal Music Source 37 Arista Systems Corporation ...

Page 38: ...5 4 3 2 1 FAX R FAX T COR4 COT4 CO Line 4 COR4 COT4 1 There are 4 CO Line Ports that can be wired on D1TKUC each CO Line Port containing 2 wires 2 The above diagram depicts the connection of a FAX machine working with FAX MONITOR function 3 FAX monitor function installation is only available on D1TKUB 38 Arista Systems Corporation ...

Page 39: ...4A CH3B CH3A CH2B CH2A D1TKUC Figure 20 Metering Pulse Detection Card Installation 1 There is a maximum of 4 D1CIDC cards that can be installed in each D1TKUB one card for one CO Line 2 The connection for the 1 st 2 nd 3 rd and 4 th CO Lines are from CH1A CH1B to CH4A CH4B 39 Arista Systems Corporation ...

Page 40: ...one Wiring for D2DLUA D2HYUA and D2SLUA 4 Wires Phone Box D2DLUA Figure 21 Digital Key Station Wiring on D2DLUA 1 ST1 ST8 are all for the Digit Key Telephone connections 2 BT BR is the Data Audio Power pair no polarity 40 Arista Systems Corporation ...

Page 41: ...air 4 NC Station 5 Pair 5 NC Station 6 Pair 6 NC Station 7 Pair 7 NC Station 8 Pair 8 NC Station 9 Pair 9 NC Station 10 Pair 10 NC Station 11 Pair 11 NC Station 12 Pair 12 NC Station 13 Pair 13 NC Station 14 Pair 14 NC Station 15 Pair 15 NC Station 16 Pair 16 NC The Above pairs refer to the standard color coding as they appear when terminated on the frames 41 Arista Systems Corporation ...

Page 42: ...ne Box Single Line Telephone Wire Figure 23 SLT Station Wiring on D1SLCB 1 Connect D1SLCB on D2MBUB 2 Only for 2 SLT ports SLT1 and SLT2 provided on D1SLCB can connect with Single Line Telephone 3 The wiring of SLT2 to connect with Single Line Telephone is analogous to that of SLT1 42 Arista Systems Corporation ...

Page 43: ... EXT PAGE Figure 24 Door Phone Wiring on D1MFCA 1 D1MFCA is an option which must be installed to provide 2 Door Phone Connection 2 This option allows the user to connect any kind of external 2 Wires Door Phone device 3 The program setting refer to Zone 602 43 Arista Systems Corporation ...

Page 44: ...gure 25 External Sensor Wiring on D1MFCA 1 D1MFCA is an option which must be installed to provide 2 Sensor Connections 2 This option allows the user to connect any kind of external SENSOR device such as Door Sensor Smoke Detector or Heat Sensor among others 44 Arista Systems Corporation ...

Page 45: ...Power EXT PAGE EXT PAGE Figure 26 Door Switch Wiring on D1MFCA 1 D1MFCA is an option which must be installed to provide 2 Relay Connections 2 This option allows the user to connect any kind of external Relay Control device such as Door Switch Loud Bell among others 45 Arista Systems Corporation ...

Page 46: ...V 96 External Music Source Installation D2MBUB External Music Source Figure 27 External Music Source Wiring on D2MBUB 1 Connect 2 conductor wiring cord from External Music Source to EXMUSIC on D2MBUB 46 Arista Systems Corporation ...

Page 47: ...utput Port of the system Wiring table View from the front of DB9 Serial Printer or PC including RS232 interface DB 9 Male Connector Standard DB 9 Cable DB 9 Male Connector D1TKUB D1MBUB D1 TKUB D1 MBUA Serial Printer or PC including RS232 interface Figure 28 RS232 Wiring on D1MBUB wired by customer 2 Install D1RSCC RSC position on D1MBUB as the FIRST RS232 interface or install D1RSCC to RPC positi...

Reviews: