EQUIPMENT REQUIREMENT

 

 

Prior to installation, carefully inspect all packages for evidence of damage.  

Compare the equipment received against equipment ordered to ensure that 

ALL components have been received. 

 

The following materials are required (not provided) for installation: 

z

  Exterior grade plywood back board for the KSU. 

z

  1 Male-Tail per extension board for Station wiring.   

z

  Appropriate mounting hardware. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

Arista Systems Corporation 

Summary of Contents for DV-38

Page 1: ...st te el l N Ne et tw wo or rk ks s DV38 INSTALLATION GUIDE Version number 1 1 issued November 2004 Aristel Networks Pty Ltd Unit 3A 100 Station Street Nunawading VIC 3161 Telephone 03 9837 2300 Facsimile 03 9872 4433 1 Arista Systems Corporation ...

Page 2: ...RTS 22 D1STUB ANALOG KEY STATION UNIT 8 KEY STATION PORTS 23 D1SLCB SINGLE LINE STATION CARD 2 SLT STATION PORTS 24 D1RSCA RS232 CARD 2400BPS SERIAL RS232 PORT 25 D1VSCA B VOICE SERVICE CARD 2 VOICE CHANNEL 28 D1MFCA MULTI FUNCTION CARD 2 SENSOR 2 RELAYS 2 DOOR PHONES 29 D1MDCA METERING PULSE CARD 30 D1RPCA REMOTE PROGRAMMING CARD 2400BPS STANDARD MODEM 32 D1VMCA VOICE MAIL CARD 33 D1VMEA VOICE MA...

Page 3: ...ONNECTOR LAYOUT 43 SINGLE LINE PHONE WIRING FOR D1SLCB 44 2 WIRES DOOR PHONE INSTALLATION 45 SENSOR INSTALLATION 46 DOOR SWITCH INSTALLATION 47 EXTERNAL MUSIC SOURCE INSTALLATION 48 RS232 SERIAL PRINTER OR PC INSTALLATION 49 3 Arista Systems Corporation SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE ...

Page 4: ...th the actual installation The National Electrical Code NEC requires the local telephone company Telecom to provide the primary protection devices for the telephone lines terminating at the customer s site Make sure that a primary protection device has indeed been installed by the Telecom If no such device is present notify the Telecom before installing your Aristel system 4 Arista Systems Corpora...

Page 5: ...ligent Digital Key Telephone System has the listed capacities trunk card basic 4 lines per card maximum 3 cards 12 ports and 8 26 extension ports It can also be equipped with the following system peripherals SMDR interface Door Phone Interface Multi Function Sensor Interface Multi Function Relay Remote Programming Interface External Music Interface External paging interface Voice Mail and Auto Att...

Page 6: ...System Installation Manual DV 38 Aristel DV 38 Digital Intelligent Key Phone System Multiple Processors Time Division Multiplexing Unique ARISTEL ASIC Chip A SERIES 6 Arista Systems Corporation ...

Page 7: ...e Phone 0 2 2 Auto Attendant 0 4 0 4 0 Voice Mail 0 0 4 0 4 Voice Service interface Recording Extension 0 26 26 Door Phone interface 0 2 2 Relay Switches 0 2 2 Sensor 0 2 2 Fax Monitor 1 2 3 RS232 For SMDR 0 1 1 Remote Programming 0 1 1 UPS interface 1 0 1 Speed Dial 1000 sets 0 1000 sets Caller ID card 0 12 12 Power Failure Transfer Phone 1 2 3 External Music 1 0 1 External Paging 0 1 1 DSS64 con...

Page 8: ... 9 9 9 9 9 9 Photo Interrupt Hook Switch 9 9 9 9 9 9 9 9 Digital Volume Control 8 Levels 8 Levels 8 Levels 8 Levels 8 Levels 8 Levels 8 Levels 8 Levels OHCA Function 9 9 9 9 One Touch Paging 9 9 9 9 9 9 9 9 Last Number Redial 9 9 9 9 9 9 9 9 Name Speed Dial 9 9 9 9 Calculator 9 9 Individual Speed Dial 9 9 9 9 9 9 9 9 Difference Ringing Frequencies 9 9 9 9 9 9 9 9 Dual Color Tri Status LED 8 keys 8...

Page 9: ...d Providing 1 RS232 port and working for SMDR Optional Card D1VSCA Voice Service Card Consisting of 2 Voice Channels 60 sec per channel for Auto Attendant applications Optional Card D1VSCB Voice Service Expansion Card Additional 2 Voice Channels 60 sec per channel for Auto Attendant applications Optional Card D1MFCA Multi Function Card 2 Doors 2 Relays 2 Sensors 1 External Paging Optional Card D1M...

Page 10: ...unction Key Assignment z Forced Account Code z Headset Function z Hot Line Hotel Motel Function w o PC z Illegal Outgoing Protection z Intercom Busy Reminder z Incoming Hunting z Incoming Paging z Intercom Hunting z Internal External Music Source z Internal External Paging ISDN Compatible z Key Station Short Protection z LCR Least Cost Routing z Lightning Protection z Manual Line z Message Waiting...

Page 11: ...On z Conference z Day Night Service Indication z Digital Volume Control 8 Levels z Do Not Disturb z Dual Color Tri Status BLF Indication z Ergonomics Receiver Handset z Handsfree Dialing Handsfree Conversation z Hold Exclusive Hold z Last Number Redial z Macro Key Setting z Message Text z Monitor Off Hook Call Announcement OHCA z Override z Page Be Paged z Station Lock Unlock z Station Name Settin...

Page 12: ...sary connecting blocks and ancillary equipment on a wall The installation site should not be in areas subject to static electricity e g Dry copiers or vibration e g Heavy machinery z A dedicated earthed power outlet for the KSU either 240VAC 50Hz or 110VAC 60Hz and a 10 Amp circuit are required An integral earth is required in the AC power cord If a music source or optional external paging equipme...

Page 13: ...ompare the equipment received against equipment ordered to ensure that ALL components have been received The following materials are required not provided for installation z Exterior grade plywood back board for the KSU z 1 Male Tail per extension board for Station wiring z Appropriate mounting hardware 13 Arista Systems Corporation ...

Page 14: ...rotector should be installed at the dedicated AC outlet z Connect Male Tail and connect the plug to each station board for station wiring also connect the wire to the RJ 11 for connector on each trunk card for the CO lines wiring z Plug in the power cord of the power supply to an AC Power Outlet and then turn on the power of the system 14 Arista Systems Corporation ...

Page 15: ...ure 1 System Inter Circuit Layout 1 AC Power Inlet 2 AC Power Switch 3 Power Indicator LED Type 4 DC Power Switch 5 For D1SLCB Earth Grounding 6 2 Wire Female Connector For External Battery Box Connection 7 Earth Ground For Lightning Protection Ground 8 Wiring Area and the Cable Outlet 9 RS232 Female DB9 for the connection to the D1RSCC 15 Arista Systems Corporation ...

Page 16: ...310 mm x 130 mm Function 1 The motherboard control entire system functions and audio switching 2 Motherboard supports External Music Source Input Terminal 3 System programming Auto Protection by Li Battery The installation site of D1MBUB 9 10 17 1 2 4 3 8 11 12 13 14 5 6 7 15 16 16 Arista Systems Corporation ...

Page 17: ...tion 8 SVR Variable Resistor to adjust the volume of the Internal Melody Source that use for BGM and MOH applications 9 MFC 13Px2 Wafer Connector for D1MFCA connection 10 SLC 13Px2 Wafer Connector for D1SLCB connection 11 STA1 3 30Px2 Header Connector for both D1DULB and D1STUB connection 12 ASIC Aristel proprietary ASIC 13 LCD Additional LCD connector for engineering system maintenance 14 JP1 3 P...

Page 18: ... for external Back up Battery The installation site of D1PWUA Figure 3 D1PWUA POWER UNIT 1 LED501 Power Indicator 2 SW101 AC Power Switch 3 CN101 AC Power Inlet 4 CN802 4 Pins Connector Reserved for further Applications 5 SW401 External backup battery Power Switch 6 CN105 Earth Terminal for D1SLCB Grounding 7 CN402 External Battery Connector Left Side is Right side is 8 CN301 6 Pins Connector for ...

Page 19: ... 4 Support either D1CIDC or D1MDCA connections on each CO line 4 3 2 1 The installation site of D1TKUC D1DTKA Figure 4 D1TKUC TRUNK UNIT 4 TRUNK PORTS 1 CN1 60 Wires rainbow Cable to connect to TKU1 3 positions where upon the D1MBUB 2 CN3 The socket for both Power Failure standard Phone and FAX connections 3 CN2 The RJ socket for POTS CO lines connections 4 CH1 4B Connectors for each CO lines to i...

Page 20: ... or 12 lines for Voice channel 7 6 5 Figure 5 D1DTKA ISDN TRUNK UNIT 2 BRI PORTS The installation site of D1DTKA 3 2 1 4 1 Test Connector for engineer testing 2 Test Connector for engineer testing 3 Flat cable connect to D1MBUB 4 RJ 45 connector to connect to ISDN BRI Line 5 JP1 jumper for first line line termination enable disable DO NOT ALTER 6 JP2 jumper for second line line termination enable ...

Page 21: ...tion enable default N C line termination disable JP2 Short line termination enable default N C line termination disable JP3 please see below table for reference Link 0 Link 1 Slot number of TKU IN IN 1 REMOVED IN 2 IN REMOVED 3 21 Arista Systems Corporation ...

Page 22: ...B could be installed onto the DV 38 main frame 24 Extensions Maximum 4 D1DLUB fully compatible with DV Series Key Telephones Ex DKP 30 DKP 31 DKP 32 DKP 33 DKP 50 DKP 51 DKP 52 DKP 53 1 2 Figure 6 D1DLUB Digital Key Station Unit 8 Key Station ports The installation site of D1DLUB D1STUB 1 STA 60 wires Rainbow Cable to connect to SAT1 3 positions where upon the D1MBUB 2 CN1 Am phenol Connector Key ...

Page 23: ...UB could be installed onto the DV 38 main frame 24 Extensions maximum 3 D1STUB fully compatible with AV Series Key Telephones Ex KP 10 Series KP 20 Series or KP30 Series 2 Figure 7 D1STUB Analog Key Station Unit 8 Key Station ports The installation site of D1DLUB D1STUB 1 1 CN1 60 wires Rainbow Cable to connect to STA1 3 positions where upon the D1MBUB 2 CN2 Am phenol Connector for analogue Key St...

Page 24: ...a special socket instead of occupying Extension ports socket 2 All of single line station can be connected to SLT ports EX SLT Modem Wireless Phone 2 1 The installation site of D1SLCB Figure 8 D1SLCB Single Line Station Card 2 SLT Station Ports 1 CN1_B 6 Pins Wafer Connector for both Single Line Telephone Ports connections 2 SLC Wafer Connector to connect to SLC Position where upon the D1MBUB 24 A...

Page 25: ...tallation site of D1RSCC 6 Figure 9 D1RSCC RS232 Card 2400bps Serial RS232 Port 1 CN 10 Pins Male Wafer Connector Connect to the position of Point 9 in Figure 1 by the special DB9 Cable FD 10 9 400 Male Type for the connection of either PC COM Port or Serial Printer 2 RSC 26 Pins Connector to connect to RSC position where upon the D1MBUB 3 Jumper Setting 3 1 JP4 3 Pins Jumper Selection JP4 Receive...

Page 26: ...t SYS Serial Printer 3 2 JP3 3 Pins Jumper Selection Receive Transmit 3 3 JP2 3 Pins Jumper Selection JP2 P SYS PC P PC COM Port rinter SYS Serial P Transmit JP2 3 4 JP1 3 Pins Jumper Selection JP1 Receive SYS PC JP1 26 Arista Systems Corporation ...

Page 27: ...IN2 SHORTED JP2 JP3 JP1 JP4 B If the system s RS232 is connected to Serial Printer please make ALL jumpers to be PIN2 PIN3 SHORTED C Note Some serial printers have already changes the TX Rx DTR DSR mode If those didn t change the system of mini jumper must change to pin1 pin2 JP2 JP3 JP1 JP4 27 Arista Systems Corporation ...

Page 28: ...ould be pre recorded the voice for Auto Attendant and Emergence Call applications 1 VSC 26 Pin Connector to connect to VSC position where upon D1MBUB 2 Expansion Connector for D1VSCB connection 3 Variable Resistors To adjust the Playing Volume of each voice channel 4 The expansion Connector to connect both D1VSCA and D1VSCB for channel expansion 4 1 2 3 The installation site of A D1VSCA B D1VSM Fi...

Page 29: ...aging Fire Alarm and Emergency Alarm etc 1 2 3 5 4 The installation site of D1MFCA Figure 11 D1MFCA Multi Function Card 2 Sensor 2 Relays 2 Door Phones 1 SEN2 Terminal Block Connector for the 2nd Sensor Connection 2 SEN2 Terminal Block Connector for the 1st Sensor Connection 3 External Page Terminal Block Connector for External Page Connection 4 DOOR2 Terminal Block Connector for the 2nd Door Phon...

Page 30: ... 21 mm Function Provide signal channel of the POTS CO line 12 16KHz Metering Pulse detection The installation site of D1MDCA 1 2 Figure 12 D1MDCA Metering Pulse Card 1 CN2 To connect to the position CH1 4B where upon the D1TKUC 2 CN1 To connect to the position CH1 4A where upon the D1TKUC 30 Arista Systems Corporation ...

Page 31: ...nction Provide signal channel of the POTS CO line DTMF FSK Calling Line Identification detection The installation site of D1CIDC Figure 13 D1CIDC CALLER ID Card 1 2 1 CN2 To connect to the CH1 4B position where upon the D1TKUC 2 CN1 To connect to the CH1 4A position where upon the D1TKUC 31 Arista Systems Corporation ...

Page 32: ... Item D1RPCA Size 70 5 mm x 69 mm Function 1 Standard 2400bps Modem 2 Cooperate with Aristel s Win SM for system remote programming and Maintenance 1 The installation site of D1RPCA Figure 14 D1RPCA Remote Programming Card 1 RPC 26 Pin Connector to connect to RPC position where upon the D1MBUB 32 Arista Systems Corporation ...

Page 33: ...on board and could be expanded up to 4 ports by D1VMEA 2 On board Flash memory chip to stores the voice message 2 3 1 Figure 15 D1VMCA Voice Mail Card The installation site of D1VSMA 1 Expansion Flash Memory for D1VMCA 2 Expansion Voice Mail Port for D1VMCA 3 Flat cable connector to connect to the VSC position where upon the D1MBUB 33 Arista Systems Corporation ...

Page 34: ...on 1 Signal channel of Voice Mail for port expansion where upon the designated socket 2 Basic 2 channels on one board Maximum capability can be expanded to 4 channels 1 The installation site of VMB 01 Figure 16 D1VMEA Voice Mail Expansion Card 1 Connect to the DSP3A DSP4A and DSP3B DSP4B positions where upon the D1VMCA 34 Arista Systems Corporation ...

Page 35: ...on Flash Memory Card provides 8 hours memory space 2 2 6 hours basic capacity on the D1VMCA 3 expansion flash memory cards could expand the memory up to 30 hours Maximum 6 24 30 hours 1 The installation site of VMB 01 Figure 17 VMB 04 Expansion Flash Memory 1 Connect to the F2A F5A and F3B F5B positions where upon the D1VMCA 35 Arista Systems Corporation ...

Page 36: ...DV 38 INSTALLATION AND WIRING AC POWER AND DC BATTERY BACK UP INSTALLATION D1TKUC D1DTKA D1MFCA D1RSC D1RPCA D1DLUB D1STUB D1VSCA D1VMCA D1SLCB Figure 18 AC Power and DC Battery Back Up Installation 36 Arista Systems Corporation ...

Page 37: ...he system can be either 115VAC or 230VAC The system can detect the input voltage automatically CAUTION There are Hazardous voltages present in the Power Supply We recommend that the Power be switched off before opening any covers 37 Arista Systems Corporation ...

Page 38: ...older CAUTION Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions 2 Music source selection and volume control for both MOH and BGM 2 1 JP2 Music Source Selection External Music Source Internal Music Source 2 2 VR1 Volume Control 38 Arista Systems C...

Page 39: ...ine 4 PFR1 PFT1 6 5 4 3 2 1 6 5 4 3 2 1 FAX R FAX T 1 There are 4 CO Line Ports that can be wired on D1TKUC each CO Line Port containing 2 wires 2 The above diagram depicts the connection of a FAX machine working with FAX MONITOR function 3 FAX monitor function installation is only available on D1TKUB 39 Arista Systems Corporation ...

Page 40: ...A CH3B CH3A CH2B CH2A D1TKUC Figure 20 Metering Pulse Detection Card Installation 1 There is a maximum of 4 D1CIDC cards that can be installed in each D1TKUB one card for one CO Line 2 The connection for the 1st 2nd 3rd and 4th CO Lines are from CH1A CH1B to CH4A CH4B 40 Arista Systems Corporation ...

Page 41: ...tal Keyphone Wiring for D1DLUB Phone Box 4 Wires D1DLUB Figure 21 Digital Key Station Wiring on D1DLUB 1 ST1 ST8 are all for the Digit Key Telephone connections 2 BT BR is the Data Audio Power pair no polarity 41 Arista Systems Corporation ...

Page 42: ...ogy Key Station Wiring on D1STUB 1 ST10 ST8 are all for the Analogy Key Telephone connections 2 AT AR is the audio pair AT Transmission Green Color AR Receiving Red Color 3 BT BR is the Data Power pair BT Pole and Data Receiving Black Color BR Pole and Data Transmission Yellow Color 42 Arista Systems Corporation ...

Page 43: ... Pair 2 for Station 4 Pair 9 NC Pair 1 for Station 5 Pair 10 Pair 2 for Station 5 Pair 2 for Station 5 Pair 11 NC Pair 1 for Station 6 Pair 12 Pair 2 for Station 6 Pair 2 for Station 6 Pair 13 NC Pair 1 for Station 7 Pair 14 Pair 2 for Station 7 Pair 2 for Station 7 Pair 15 NC Pair 1 for Station 8 Pair 16 Pair 2 for Station 8 Pair 2 for Station 8 Pair 17 NC NC Pair 18 NC NC Pair 19 NC NC Pair 20 N...

Page 44: ... Phone Box D1 SLCA Figure 23 SLT Station Wiring on D1SLCB 1 Connect D1SLCB on D1MBUB 2 Only for 2 SLT ports SLT1 and SLT2 provided on D1SLCB can connect with Single Line Telephone 3 The wiring of SLT2 to connect with Single Line Telephone is analogous to that of SLT1 44 Arista Systems Corporation ...

Page 45: ... EXT PAGE Figure 24 Door Phone Wiring on D1MFCA 1 D1MFCA is an option which must be installed to provide 2 Door Phone Connection 2 This option allows the user to connect any kind of external 2 Wires Door Phone device 3 The program setting refer to Zone 602 45 Arista Systems Corporation ...

Page 46: ...gure 25 External Sensor Wiring on D1MFCA 1 D1MFCA is an option which must be installed to provide 2 Sensor Connections 2 This option allows the user to connect any kind of external SENSOR device such as Door Sensor Smoke Detector or Heat Sensor among others 46 Arista Systems Corporation ...

Page 47: ...A AUX EXT PAGE EXT PAGE Figure 26 Door Switch Wiring on D1MFCA 1 D1MFCA is an option which must be installed to provide 2 Relay Connections 2 This option allows the user to connect any kind of external Relay Control device such as Door Switch Loud Bell among others 47 Arista Systems Corporation ...

Page 48: ...V 38 External Music Source Installation D1MBUB External Music Source Figure 27 External Music Source Wiring on D1MBUB 1 Connect 2 conductor wiring cord from External Music Source to EXMUSIC on D1MBUB 48 Arista Systems Corporation ...

Page 49: ...rd DB9 to RJ11 Convertor RED Color Box Female DB9 to RJ11 Convertor GREY Color Box Female DB 9 Male Connector RS232 Output Connector Serial Printer or PC including RS232 interface D1 TKUB D1 MBUA RS232 Serial Printer or PC including RS232 interface Figure 28 RS232 Wiring on D1MBUB wired by customer 2 Install D1RSCC RSC position on D1MBUB as the FIRST RS232 interface or install D1RSCC to RPC positi...