Revised by R. Robinson
Issue AV1.13 8 June 2006
25
Zone 229
Slt Busy Rem
Default value =
1
Range =
(0 ~ 1)
This zone also sets the timer for External conference / forward calls. This Zone allows or disallows Busy
Reminder Tone to be heard from an SLT. When a busy extension has a second I/C call transferred to it, the
tone will be heard through the hand piece. Timing is set in
NOTE! AV8 & AV12 do not have BRT on SLT ports
Note!
must be a value greater than 015 if
VSU
FITTED
1
TIME =
x 1
10 SEC. =
BOTH
PARTIES
HEAR BEEP
5 SEC. =
BOTH
PARTIES
HEAR
MESSAGE
CODE 07
CALL IS
DISCONNECTED
VSU
FITTED
4
TIME =
10 SEC. =
ONLY B
PARTY
HEARS
BEEP
5 SEC. =
BOTH
PARTIES
HEAR
MESSAGE
CODE 07
CALL IS
DISCONNECTED
VSU
FITTED
5
TIME =
10 SEC. =
BOTH
PARTIES
HEAR BEEP
5 SEC. BOTH
PARTIES
HEAR
MESSAGE
CODE 07
CALL IS
DISCONNECTED
NO VSU
1
TIME =
x 1
10 SEC. =
BOTH
PARTIES
HEAR BEEP
5 SEC. =
BOTH
PARTIES
HEAR BEEP
CALL IS
DISCONNECTED
NO VSU
4
TIME =
10 SEC. =
BOTH
PARTIES
HEAR BEEP
10 SEC. =
ONLY B
PARTY
HEARS
BEEP
CALL IS
DISCONNECTED
NO VSU
5
TIME =
10 SEC. =
BOTH
PARTIES
HEAR BEEP
10 SEC. =
BOTH
PARTIES
HEAR BEEP
CALL IS
DISCONNECTED
Related Zones.
,
,
Zone 230
Link Monitor
Default value =
0
Range =
(0 ~ 1)
This Zone allows the system to maintain the cross-links connections when a call has disconnected in an
abnormal manner.
0 = Disable
1 = Enable
Related Zones.
None
Zone 231
Volume Initi VAL.
Default value =
3
Range =
(1 ~ 8)
Start-up volume level for Speaker, Ringing and Handset tones for Keyphones. 8 initial levels can be set.
NOTE! The system must be powered down / up for the data change to take affect.
Related Zones.
None