background image

AN1804 4G Intercom 

Revision ARB2.8

, Apr. 2020 

 

 

Thank you for purchasing the AN1804-4G Intercom. Please read this manual before using. 
Be sure to keep this manual for future reference in case of any problem or questions. 

 

 

 

 

 

IMPORTANT SAFTY INSTRUCTIONS

 

 

When using this Intercom, basic safety precautions should always be followed to reduce the risk of 

fire, electric shock and personal injury. Please read the following before using your equipment. 

1.   Follow all warning and instructions on the product. 

 

2.   Unplug all  the  connections  of  product  before  cleaning.  Do  not  use  liquid  cleaners  or  aerosol 

cleaners. Use a damp cloth for cleaning. 

3.   Do not use this product near water. 

 

4.   Do not use this product near an area where there is a potential of gas leaks or near any fumes 

that can be explosive. 

5.   Do not place this equipment near or over a radiator or any other heat source. 

 

6.   Do not overload the wall outlet or power cord where the power adapter is installed. This can 

result in fire or electric shock 

7.   Avoid  spilling liquid  on this  equipment and  do not  insert  any objects  through  the  ventilation 

slots. 

8.   Avoid using the equipment during an electrical storm. There is a remote risk of electrical shock 

from lighting. 

 

INTRODUCTION

 

 

 

The 4G door station AN1804-4G is an intercom system and access control device which can be installed 
at the entrance of a building, gate, fence or door. The device can operate on local 12-24 volt AC or DC 
power. It enables you to speak with visitors from any location on or off the premises. 
Door or gate release is activated from your phone keypad by pressing * during the conversation and can 
also be activated by calling the SIM card number in the unit from an authorized phone number ( guest ). 
The door unit will recognize an authorized phone ( guest ) number calling it and will not answer the call, 
but will release the door or gate.    This is a free call. 

Summary of Contents for AN1804-4G

Page 1: ...4G Intercom Revision ARB2 8 Apr 2020 1 ARISTEL NETWORKS AN1804 4G INTERCOM ACCESS CONTROL OPERATING MANUAL For your protection read these instructions completely Keep for future reference For Models AN1804 4G ...

Page 2: ... OPERATION 8 Enter Listener Monitoring Mode 10 Enter Access Control Mode 10 Enter Programming Mode 10 Programming 11 Door Gate Release 12 Check Signal Strength 14 Check Relay Status 14 Administrator Number 14 CHECK A LOG OF DIAL IN AND DIAL OUT NUMBERS VIA E MAIL OR SMS 15 USER COMMANDS 18 HOW TO RESET THE HARDWARE IF YOU FORGET YOUR PASSWORD 20 SPECIFICATIONS 20 QUICK PROGRAMMING VIA SMS 21 TROUB...

Page 3: ...diator or any other heat source 6 Do not overload the wall outlet or power cord where the power adapter is installed This can result in fire or electric shock 7 Avoid spilling liquid on this equipment and do not insert any objects through the ventilation slots 8 Avoid using the equipment during an electrical storm There is a remote risk of electrical shock from lighting INTRODUCTION The 4G door st...

Page 4: ...ntercom Revision ARB2 8 Apr 2020 4 INTERCOM ACCESSORIES Item Description Q ty Included Optional 1 AN1804 4G Intercom 1 2 Power adapter 1 3 External antenna 1 4 Mounting Bracket for antenna 1 5 Operational manual 1 ...

Page 5: ... ARB2 8 Apr 2020 5 INSTALLATION This 4G Intercom is suitable for both flush and surface mounting Note For surface mounting you will have to remove the plastic enclosure before fitting main station into the stainless steel cabinet ...

Page 6: ...AN1804 4G Intercom Revision ARB2 8 Apr 2020 6 Intercom Unit Speaker Call Button Microphone Wiring Diagram ...

Page 7: ...Ensure the power is OFF before inserting the SIM card Carefully slide the SIM holder in the OPEN direction insert the SIM and slide in the CLOSED direction to lock it in place 2 Antenna Install the antenna as high as possible for best possible reception 3 Door Lock Connect an electric door lock to terminals marked door latch 4 Power Supply Connect a 12 24 volt power source to terminals marked AC A...

Page 8: ... will open the door The relay switches can also be temporarily or permanently switched on or off by press and 1 The AN1804 4G intercom supports all Telstra Optus Vodafone CSFB networks Enter system menu There are three different modes under system menu 1 Listener monitoring mode 2 Access control mode 3 Programming mode To gain access to the system menu via dial in follows these steps 1 Call the te...

Page 9: ...AN1804 4G Intercom 9 Revision ARB2 8 Apr 2020 ...

Page 10: ...ed numbers 3 You will hear a Do tone to enter access control mode by pressing 33 5678 where 5678 is the password 4 The door will open after entering the correct password To open the door by password if the number is not stored in the access control section Enter Programming Mode 1 Call the telephone number of the intercom 2 This device will then verify your phone number with your predefined number...

Page 11: ...st start with the pass code default 1234 in the following format 12 1234 Followed immediately by a command 4 To program a call button numbers DO NOT enter country code just the complete number as you would dial it Example Storing a call button phone number Max 3 numbers and delete 2 3 phone numbers Refer to user commands P 16 058 57235 landline number 1 086 5682554 mobile number 2 086 2235644 mobi...

Page 12: ...bleeps You may now program up to 1152 telephone numbers into memory Use the following commands to program the unit Insert international country code 1 3 digits 71 country code Add a number up to 1152 numbers 72 relay telephone number Delete a number 73 telephone number Delete all numbers 73 Door Gate Release ring in to open This intercom also has a feature to allow users to gain access from their ...

Page 13: ...n to open guest list SMS format to delete phone number 1 and 2 12 1234 730865683624 730865682554 SMS format to delete all numbers 12 1234 73 After the numbers are programmed you can also send the text message to check the stored numbers by sending SMS format 21 then the GSM intercom will reply the phone number list text message 2 Access control password to open Dial the SIM card telephone number T...

Page 14: ...mmand code to check relay status SMS format 22 SMS Reply Relay ON Detect ON Relay Hold Detect GND Remark Terminal mark Detect see wiring diagram is for you to connect a door reed switch The gates would have a reed switch wired through the DET input to ground It s used by the user to check if the gates are open or closed Administrator Number Once the administrator number is stored the unit will onl...

Page 15: ...CHAP Command code Example 4 E mail parameters setting Doesn t support default Gmail 41 1234 SMTP server port user name password e mail address e mail sender name Command code Example 5 Recipient Carbon copy settings 42 1234 recipient e mail address recipient name carbon copy e mail address carbon copy name Check the log of dial in and dial out numbers via E mail or SMS This system allows you to sa...

Page 16: ...mbers via SMS 12 1234 85 11 SIM phone number used in intercom for Clock date and time correction 12 1234 86 SIM phone number used in the intercom 12 To delete SIM phone number used in the intercom for Clock date and time correction 12 1234 86 Remark why you need to setup the number for system time clock date and time correction This device has a time clock and supports automatically updating their...

Page 17: ... will need to make this feature work You can program many different user command codes in a single text message with SMS command format 12 1234 command Code1 command Code 2 command Code3 Example Mobile number for receiving a log 0907967223 SIM phone number used in opener 0948778458 12 1234 841 850907967223 860948778458 Send 44 1234 to check log Replied log information via SMS example ...

Page 18: ...onitoring Mode 13 password To hear the surroundings where the intercom installed 1212 3 Enter Access control Mode Trigger relay 33 password Password mode access option 5678 4 Hold Relay 34 password To hold relay to keep door opened 5678 5 Release Relay 35 password To release relay for door close 5678 6 Trigger relay 2 36 password Password mode access option 5678 7 Hold Relay 2 37 password To hold ...

Page 19: ...atus ON OFF 4 Modify the SMS content of Detect PIN triggered 26 password SMS Content Reply SMS Content 5 Trigger relay 33 password No reply default password 5678 Latch on when relay is on hold status 6 Hold relay 34 password No reply default password 5678 7 Release relay 35 password No reply default password 5678 8 Trigger relay 2 36 password No reply default 5678 Latch on when relay is on hold st...

Page 20: ...me level 0 4 3 8 Relay Time 51 relay time relay time 1 9999 sec 1 9 Relay 2 Time 50 relay 2 time relay time 1 9999 sec 1 10 Call no answer time and divert to next number 52 no answer time No answer time 10 99 sec 20 sec 11 Max call Time 53 max call time Max call time 005 999 sec 060 sec 12 Max monitoring time 55 duration time duration time 00 60 mins 00 no limit 10 mins 13 Change call tone of pres...

Page 21: ...nable SMS reply notice 894 X X 0 disable X 1 enable SMS replay Relay 1 trigger relay 2 trigger Relay 1 hold relay 2 hold Relay 1 release relay 2 release 0 21 Disable enable Call button LED flashing 896 X X 0 disable X 1 enable 0 22 Dial tone volume 898 X X 1 4 levels 3 23 Pin DET type 902 Type 0 Disable 1 Egress mode 901 2 Trigger 3 Resistance 10KΩ 7 5K 13K 0 24 Reset 999 reset default None How to...

Page 22: ...untry code Command to use 12 1234 71 country code 72 relay phone number 72 relay phone number 72 relay phone number Example Ireland Country code 353 UK 44 USA 1 086 5683624 mobile number 1 086 5682554 mobile number 2 086 2235644 mobile number 3 SMS format 12 1234 71353 7210865683624 7210865682554 7220862235644 Operation When intercom calling your phone and you have answered the call Press to open ...

Page 23: ...inspect that the centre pin inside the antenna is intact and has not been pushed back inside the fitting Q The unit calls the first number but there is not enough time to answer before it diverts to the next number A Increase the no answer time as per programming instructions Q The unit calls the first number but voicemail comes on before it can ring the second number A Decrease the no answer time...

Page 24: ...the relay and the lock or gate panel If the relays do not make a clicking sound then check this feature on a different mobile cell phone or landline If it works on a different phone check the settings on the phone in question under DTMF tones Failure of DTMF tones to operate correctly is also a symptom of low reception Check steps above on improving reception Try pressing the buttons longer when a...

Page 25: ...AN1804 4G Intercom Revision ARB2 8 Apr 2020 25 E O E www aristel com au ...

Reviews: