Summary of Contents for AN1706

Page 1: ...3G GSM Gate Opener 1 18 Rev V1 4B Jan 2019 ARISTEL NETWORKS MANUAL 3GGATEOPENER AN1706 WCDMA Please read these instructions completely before use ...

Page 2: ... Wiring Diagram 5 5 4 Power Supply 6 6 LED INDICATORS 7 7 OPERATION 8 8 PROGRAMMING 8 8 1 Programming by dialing in 8 8 2 Programming by text message 9 9 ADMINISTRATOR NUMBER 10 10 CHECK SIGNAL STRENGTH 10 11 CHECK RELAY STATUS 10 12 HOW TO RESET THE UNIT WHEN YOU FORGET THE PASSWORD 10 13 CHECK A LOG OF DIAL IN NUMBERS VIA E MAILOR SMS 11 14 USER COMMANDS 14 15 SPECIFICATIONS 17 16 QUICK PROGRAMM...

Page 3: ... or electric shock 6 Avoid spilling liquid on this equipment and do not insert any objects through the Ventilation slots 7 Avoid using the equipment during an electrical storm There is a remote risk of electrical shock from lighting 2 BRIEF INTRODUCTON 3G GSM Gate Opener is a SIM based remote control system which can activate automatic gates with a free call from you mobile phone The users phone n...

Page 4: ...utputs and 3 inputs for switching contacts alarm output sensors etc 8 Automation industrial process intruder alarm dialer and more 4 STANDARD PACKING LIST Item Description Q ty Included Optional 1 3G GSM Gate Opener 1 2 Adapter 1 3 Short Antenna 1 4 External Antenna 3 meter length 1 5 Bracket for antenna 1 6 Manual 1 5 INSTALLATION 5 1 SIM CARD INSTALLATION Fig1 1 Ensure power is off before insert...

Page 5: ...t the location where it wil be installled 2 If you use an antenna with a 3 metre cable install it as high as possible on the top of the pillar for best possible reception 5 3 WIRING DIGRAM Fig2 Fig3 Fig2 Interface introduction 1 2 3 4 5 6 7 8 9 A B C GND IN1 Lo IN2 Lo IN3 Hi NO2 COM2 NC2 NO1 COM1 NC1 AC2 AC1 Fig1 ...

Page 6: ...M Gate Opener is designed to work with power supplies 12V 24V AC or DC The power supply should be capable of supplying a constant current of no less than 1amp After a final check of wiring switch on the power allow 20 30 seconds for the unit to boot up and detect the network ...

Page 7: ...me 2 Trigger input 2 Input 2 active Sending SMS Standby In triggering setup time 17 Time 3 Trigger input 1 Input 1 active Sending SMS Standby In triggering setup time 15 Time 4 Power Power ON Power OFF X 5 3G GSM Network Busy or searching Module OFF Flashes once per second Standby 6 Device status Standby Power OFF Flashes once per second No SIM inserted Flashes twice per second SIM not registered ...

Page 8: ...call and you will hear a bleep tone The door can be opened after enter correct password code Or just simply send SMS password code to the device 71 5678 Trigger relay 1 72 5678 Hold relay 1 73 5678 Release relay 1 74 5678 Trigger relay 2 75 5678 Hold relay 2 76 5678 Release relay 2 This is for door open option when telephone numbers are not stored 8 PROGRAMMING Programming can be carried out eithe...

Page 9: ...Single SMS text messages is limited to 140 characters 2 You can program many different user command codes in a single text message with SMS command format 12 1234 command Code1 command Code 2 command Code3 3 Each SMS must start with the pass code default 1234 in the following format 12 1234 Followed immediately by a command Program with the following format 12 1234 71 country code 72 relay phone n...

Page 10: ...CKING SIGNAL STRENGTH When a request for 3G GSM signal strength send an SMS command is sent to the 3G GSM Opener The unit should reply with a signal strength code and service provider name The code will be between 0 31 means the signal level is from poor to best Example SMS format 21 1234 SMS reply Vodafone Signal Level 31 Signal is very strong 11 CHECK RELAY STATUS You can send SMS command code t...

Page 11: ...eaches 100 numbers default N 1 sending when it reaches 200 numbers Max Sending record when it reaches 200 numbers command code example 12 1234 831 2 Way of sending a log of dial in numbers via e mail or SMS 12 1234 84 N N 0 no saving sending record N 1 via SMS 4 numbers limited SMS N 2 via E mail Sending record via email command code example 12 1234 842 3 GPRS parameters setting 40 1234 APN auth_t...

Page 12: ...234 85 11 SIM phone number used in opener for Clock date and time correction 12 1234 86 SIM phone number used in opener 12 To delete SIM phone number used in opener for Clock date and time correction 12 1234 86 Note why you need to setup the number for system time clock date and time correction This device has a time clock and supports automatically updating their date and time via NITZ informatio...

Page 13: ...many different user command codes in a single text message with SMS command format 12 1234 command Code1 command Code 2 command Code3 Example Mobile number for receiving a log 0907967223 SIM phone number used in opener 0948778458 12 1234 841 850907967223 860948778458 Send 44 1234 to check log Replied log information via SMS example I Dial IN numbers N Next text massage E End text message ...

Page 14: ...ivation time Time 1 9999 seconds 1 6 14 Time Activation time when input 1 is trigged Time 1 9999 seconds 0 sec no delay 7 15 Time Sending SMS duration when input 1 continues triggering Time 0 60 minutes 15 Tim e 8 16 Time Activation time when input 2 is trigged Time 1 9999 seconds 0 sec no delay 9 17 Time Sending SMS duration when input 2 continues triggering Time 0 60 minutes 0 min no delay 10 23...

Page 15: ...its UK 44 USA 1 886 20 72 relay phone number Store phone number For ringing in to open the door max 100 numbers Relay 1 or 2 Phone number 3 14 digits N A 21 73 phone number Delete a ring in to open number phone number 3 14 digits N A 22 73 Delete all ringing in to open numbers 23 74 admin number Add administrator phone number admin number 3 14 digits no number no restriction N A 24 74 Delete admin...

Page 16: ...igh low 5 31 1234 SMS content Store SMS content when input 1 is triggered SMS content max 100 characters 6 31 1234 To check input 1 SMS content Default SMS trigger 1 is active 7 32 1234 SMS content Store SMS content when input 2 is triggered SMS content max 100 characters 8 32 1234 To check input 2 SMS content Default SMS trigger 2 is active 9 33 1234 SMS content Store SMS content when input 3 is ...

Page 17: ...rogram a phone number for dial in door release Max 100 numbers Note Program a phone number for dial in door release you NEED TO enter country code 12 1234 71 country code 72 relay phone number 72 relay phone number 72 relay phone number Relay 1 or 2 Example Ireland Country code 353 UK 44 USA 1 Do not using any leading zeroes 086 5683624 mobile number 1 086 5682554 mobile number 2 086 2235644 mobil...

Page 18: ...3G GSM Gate Opener 18 18 Rev V1 4B Jan 2019 76 5678 Release relay 2 Active Online www activeonline com au Ph 1300 816 742 E sales activeonline com au ...