O-235 | 3 - Access Point Overview | 8
Label
Description
1
Reset
2
USB
3
Console
Port
Description
Connector
Type
Speed/Protocol
Console
Establish ‘config shell’ terminal session via serial
connection
RJ-45
•
RS 232 Serial (115200
bits per second)
•
Data bits:8; Stop bits: 1
•
Parity: None
•
Flow Control: None
USB
USB 2.0 port
USB
Future Use
Reset
Reset to factory default settings port. Hold down and power
cycle the device to reset.
Pinhole push
button
N/A
When you reset the AP, the following settings are reset:
•
Config shell password is reset to config.
•
Server discovery value is erased and changed to the default,
redirector.online.spectraguard.net (primary) and wifi-security-server (secondary).
•
All the VLAN configurations are lost.
•
If a static IP is configured on the AP, the IP address is erased and DHCP mode is set. The
factory default IP address of the AP is 169.254.11.74.
Rear Panel
The rear panel of the AP has LAN/PoE+ connectors that enable you to connect the AP to a wired
LAN through a switch or a hub. The ports provide power to the AP by using the 802.3at standard.
Use an active wrench to open the LAN cap.
Figure: O-235 Rear Panel