Speed/Protocol
Connector Type
Description
Port
RJ45
To establish 'Config Shell'
terminal session via serial
connection.
Ethernet
• RS 232 Serial Bits per second:
115200
• Data Bits: 8, Stop Bits: 1
• Parity: None
• Flow Control: None
Not in use
Not in use
USB 2.0 port
USB
Hold down and power cycle the
device to reset
Pin hole push button
Reset to factory default settings
Reset Pinhole
The Reset Pin Hole and the USB port are on the top side of the device as shown in the figure above. The Reset
Pinhole resets the C-130E device to factory defaults. To reset the device, press and hold the Reset Pin Hole for
10 sec until all LEDs go off which indicates that the device has rebooted. Pressing the Reset Pin Hole while the
device is booting up will not have any effect. You should perform this operation only when the device is running.
When you reset the device, the following settings are reset:
• Config shell password is reset to config .
• Server discovery value is erased and changed to the default, wifi-security-server .
• All the VLAN configurations are lost.
• If static IP is configured on the device, the IP address is erased and DHCP mode is set. If DHCP fails the factory
default IP address of the device is set to 169.254.11.74.
The USB port on the C-130E is currently not in use.
External Antenna Ports on C-130E
Make sure the antennas are connected to the respective RP-SMA type of connector ports as shown below:
Figure 5: External Antenna Ports
C-130E
10