17
Inst
allation instructions
Horizontal straight pencil line
Ceiling
4-12/16" circle center to wall
8-1/2" dia. hole
FOR CEILING VENT DUCTING
FOR WALL VENT DUCT
Circle center at 23
12/16" above the
marked bottom
pencil line.
Ceiling ducting
If the duct will vent straight up to the ceiling:
•
Use level to draw a line straight up, from the centerline on the template to the ceiling
.
•
Measure at least 4 -12/16 ” from the back wall to the circle center of an 8-½” hole on the ceiling.
Wall ducting
If ductwork will vent to rear:
•
Use a level to draw a line straight up from the centerline on the template
.
•
Measure at least 23 - 12/16" (the measure might vary dependig on the elbow used) above the pencil
line that indicates the bottom installation height, to the circle center of an 8-½” diameter duct hole
(Hole may be elongated for duct elbow).
House wiring location
•
The junction box is located on the top left side of the hood
.
•
Wiring should enter the back wall at least 20" above the bottom of the installation height, and within
5-7/8" and 4-7/8"of the left side of the centerline.