6
2.
Mark with a pencil the lower mounting holes location.
3.
Uninstall the hood assembly, and drill
3
⁄
16
” (4.8 mm) pilot
holes at marked locations.
4.
Hang the range hood again on 2 upper mounting screws.
5.
Level the range hood and tighten upper mounting screws.
6.
Install 2 - 5 x 45 mm lower mounting screws and tighten.
Use the optional wall anchors if needed.
Connect Vent System
1.
Install transition on top of hood (if removed for shipping) with
2 - 3.5 x 9.5 mm sheet metal screws.
A
B
A. Vent transition
B. 3.5 x 9.5 mm screw
For vented installations only:
2.
Fit vent system over the exhaust outlet.
3.
Measure from the bottom of the air deflector to the bottom
of the hood outlet. Cut the ductwork at the measured
dimension.
Dimension
to measure
Roof
outlet
Wall
outlet
4.
Seal connection with clamps.
5.
Check that back draft dampers work properly.
Electrical Connection
WARNING: Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.
Disconnect power.
2.
Remove terminal box cover.
3.
Remove the knockout in the terminal box cover and install
a UL listed or CSA approved
1
⁄
2
” strain relief.
A
B
C
A. Terminal box
B. Knockout
C. Terminal box cover
4.
Run home power supply cable through strain relief, into
terminal box.
A
B
C
D
E
F
A. Home power supply cable
B. UL listed or CSA approved
strain relief
C. Black wires
D. UL listed wire connectors
E. White wires
F. Green (or bare) and
yellow-green ground wires
5.
Use UL listed wire connectors and connect black wires
(C) together.
6.
Use UL listed wire connectors and connect white wires (E)
together.