Aries HIGH PURITY WATER SYSTEM Operation & Maintenance Manual Download Page 12

9.0    OPTIONS and ACCESSORIES

                                                            

FOR CARTRIDGES – USE ARIES FILTERWORKS VP SERIES CARTRIDGES

9.1 220 Volt Operation (HPA-008)

The ARIES can be made to operate on 220 Volt 50/60 hz version with the addition of an external step  down

transformer..

9.2 Wall Mounting Bracket (N/A)

Where counter space is limited, a 

Wall Mounting Bracket

 is available to support the ARIES Unit from any wall

that can support a 55 pound load on two  16  inch  centers.  Note:  Depending  on  materials  of  wall construction,

backing material may be required.

9.3 ARIES HPL-RO, Reverse Osmosis Pretreatment Package (HPL-RO)

When available feed water quality fails to meet the minimum requirements pretreatment with Reverse Osmosis

will increase ultimate water purity and increase cartridge life.  Consult ARIES Filter Work  or  you  water  treatment

dealer for further information.

9.4 Aries HPL-RO Replacement Cartridge Kit (AFK-005)

Replacement cartridge kit includes (1) 5.0 micron prefilter, (1) GAC carbon filter, and (1) 1.0 micron post filter

9.5 Aries HPL-RO Replacement Membrane (AM-12-7010)

Replacement membrane is a thin film composite PA membrane with 100 GPD output.

9.6  Combination UV system for Bacteria and TOC Reduction (HPA-002)

Ultraviolet light system with a combination of 185 nm and 254 nm wavelengths for bacteria sterilization and total

organic carbon (TOC) reduction.

9.7  Replacement Bulb for Combination UV system (HPA-003)

Replacement bulb with 4 pin connection.   Dual wavelength bulb.

9.8   Replacement pump for Aries System (1200103)

110 VAC pump with _” MNPT connections

The following options & accessories are supplied as kits and include detailed instructions for

assembly onto the basic design

The use of attachments or accessories not approved by this manufacturer may adversely

affect the water purity or cause appliance damage and void the warranty.

For questions regarding these and other options & accessories that may be available for

system specific needs, or for components to aid installation, please contact an authorized

dealer in your area or contact the factory.

Summary of Contents for HIGH PURITY WATER SYSTEM

Page 1: ...ARIES HIGH PURITY WATER SYSTEM Operation Maintenance Manual Version 1 1a...

Page 2: ...u have any questions concerning the operation of the unit or need service refer to section 11 0 REQUESTING SERVICE When requesting service you will need the model and serial number as well as the purc...

Page 3: ...Principles of Purifying Water 4 0 Product Specifications 5 0 Before Using Your Dispenser 5 1 Setup 5 2 Installing the Cartridges 5 3 Startup Procedure 5 4 Initial Polishing of new cartridges 6 0 Displ...

Page 4: ...er cord grip the plug and pull it from the wall outlet NEVER PULL ON CORD DO NOT use this appliance outdoors This appliance is intended for commercial industrial institutional and professional use Use...

Page 5: ...ure successful water system operation Trace organic chemicals can interfere with highly sensitive reactions and alter biological processes TDS Total Dissolved Solids conduct electricity This conductiv...

Page 6: ...t a glance The quick connect cartridge system makes replacing filters a simple task For optimum performance the Aries High Purity Water System may require reverse osmosis distillation or deionizing pr...

Page 7: ...sformer UV Combination for Bacteria and TOC Wall Mounting Kit Reverse Osmosis Pre treatment Packages Re circulating Spray Gun 0 05 micron Pyrogen removal filter Typical Applications Media Prep Tissue...

Page 8: ...tion valve at this time 5 2 Installing the Cartridges There are three 3 cartridge positions The water flows from left to right Any pretreatment filters must be installed in position 1 furthest from th...

Page 9: ...g to confirm the effectiveness of the treatment process is the owners responsibility 6 0 DISPLAY AND KEYPAD FUNCTIONS Be sure you understand the function of each button before using them Function Keys...

Page 10: ...e top cover by removing the phillips head screws that attach it Gently lift the top cover up and left and set it aside Unclasp the clamps that hold the stainless steel body of the UV light Gently lift...

Page 11: ...rom the outlet Place a wad of paper towels around each plunger to absorb the small amount water that will come out of the filters plungers and or upper fitting Remove the three cartridges starting wit...

Page 12: ...s 1 5 0 micron prefilter 1 GAC carbon filter and 1 1 0 micron post filter 9 5 Aries HPL RO Replacement Membrane AM 12 7010 Replacement membrane is a thin film composite PA membrane with 100 GPD output...

Page 13: ...se barb connection 9 12 Blank Sanitization Cartridges VP 17 0000 Blank VP Style cartridges for sanitization of unit 3 required per Aries System Sanitization kit sold separately 10 0 REQUESTING SERVICE...

Page 14: ...turned on Bad Solenoid Have unit serviced by an authorized dealer or return to factory A filter cartridge is loaded with particles and plugged No flow Replace the filter cartridge Capsule filter is bo...

Page 15: ...llege of American Pathologists ASTM American Society for Testing and Materials NCCLS National Committee for Clinical Laboratory Standards EU Endotoxin Units N L No Limit The measurements of pH in Type...

Page 16: ...anty ARIES ResinTech Inc assumes no other responsibility or liability This warranty does not cover any product which has been subject to misuse neglect accident or used in violation of operating instr...

Reviews: