11 - 38
2 sets of contacts, one normally open, one normally closed. Contact resistance is 0.1-0.3 ohms when correct.
Normally open contacts manually activated. Contact
Resistance is 0.1-0.3 ohms when correct.
Pins 85-86 coil resistance 87-100 ohms. pins 30-87 normally open. Pins 30-87A normally open. Contact resistance
is 0.1-0.3 ohms when correct.
(A) When PTO switch is on.
Pins 85-86 coil resistance 87-100 ohms. pins 30-87 normally open. Pins 30-87A normally closed. Contact
resistance is 0.1-0.3 ohms when correct.
(A) With neutral switch engaged and PTO switch off.
PTO Switch
Off
Run
Start
Brown
11.50-13.00 Volts
Purple
11.50-13.00 Volts
11.50-13.00 Volts
Red/Green
11.50-13.00 Volts
11.50-13.00 Volts
Brown/Yellow
11.50-13.00 Volts
Neutral Switch
Off
Run
Start
Brown/Yellow
11.50-13.00 Volts
Red/Green
11.50-13.00 Volts
11.50-13.00 Volts
PTO Relay
Off
Run
Start
Green/White
86
11.50-13.00 Volts(A)
11.50-13.00 Volts(A)
Black/White
85
Connected to ground when start relay
energized
Purple/White
87
11.50-13.00 Volts
11.50-13.00 Volts
87A
Not Used
Not Used
Purple
30
11.50-13.00 Volts
11.50-13.00 Volts
Start Relay
Off
Run
Start
Red/Yellow
86
11.50-13.00 Volts(A)
11.50-13.00 Volts(A)
Black
85
Connected to Ground
Black/White
87
White/Black
87A
Connected to Ignition Module
Black
30
Connected to Ground