Aria QBV080 Owner'S Manual Download Page 12

QBV080 12

 

ENGLISH

Installation (continued)

INSTALLING THE GRILLE

 

-

Squeeze the springs on the grille together, and insert the 
springs into the slots of the housing assembly . Firmly push 

the grille up against the ceiling. See figure 22.

Spring slot

Ceiling

Fig . 22

Operation

TURNING ON/OFF THE UNIT

 

-

Use an external ON/OFF switch to operate this ventilation fan .

 

WARNING:

 

To Reduce The Risk Of Fire Or Electric 

Shock, Do Not Use This Fan With Any Solid-State 

Speed Control Device .

Care and Cleaning

WARNING:

 

Failure to maintain basic standards of care and cleaning of the ventilation fan incr

eases the risk of fire, electric shock, 

or injury to persons. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means 
to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel.

The ventilation fan should be cleaned regularly (internally and externally) to preserve its appearance and performance .

Do:

Do Not:

 

-

Use a dusting brush attachment to gently vacuum 
the exterior and interior of the ventilation fan to 
remove dust and debris .

 

-

Do not let plaster dust or any other construction 
residue enter the fan . During construction or 
renovation, cover the fan .

 

-

Combustible products used for cleaning such as 
acetone, alcohol, ether, or benzol are highly explosive 
and should never be used close to the fan .

Summary of Contents for QBV080

Page 1: ...VENTILADOR ULTRA SILENCIOSO PARA CUARTO DE BA O PLEASE READ AND SAVE THESE INSTRUCTIONS INSTALLER PLEASE LEAVE THIS GUIDE WITH THE HOME OWNER LISEZ ET CONSERVEZ CES INSTRUCTIONS INSTALLATEUR LAISSEZ...

Page 2: ...ciation NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage elect...

Page 3: ...ed by loss of use of this product costs incurred for labour or materials removal and installation of replacement units or any other incidental or consequential damages Costs relating to obtaining acce...

Page 4: ...l Safety goggles Drywall saw Pry bar Wood screws Respiratory mask Cable clamp Flexible duct connector Duct adapter For best performance use 4 round metal ducting Other ducting is acceptable but may im...

Page 5: ...mage and or missing parts immediately to our customer service team at cs conglomkb com or 1 877 333 0098 Service available in English and French Monday Friday from 8 30 am 5 00 pm EST Please do not di...

Page 6: ...BV080 6 ENGLISH Pre Installation continued TYPICAL INSTALLATION Roof Cap Wall Cap Elbows Aluminum Foil Tape Power Cable Insulation Ventilation Fan Round or Flexible Duct Connector Not Included or Fig...

Page 7: ...ate so it can be enlarged to fit the new fan if required Check to ensure the joist arrow indicated on the template is oriented correctly It should be pointing towards the ceiling joist Mark the center...

Page 8: ...is required for this ventilation fan Check with qualified electrician if you are not sure whether the ventilation fan is properly grounded 2 Failure to follow electrical requirements may result in a...

Page 9: ...he power switch on the junction box before installing this unit Touching circuitry inside the ventilation fan while it is energized will result in death or serious injury DANGER All electrical wiring...

Page 10: ...aker or the power switch on the junction box before installing this unit Touching circuitry inside the ventilation fan while it is energized will result in death or serious injury NOTE Ensure your fan...

Page 11: ...ent ways to secure the housing to your ceiling joists both conventional and I joist Choose the method most appropriate to your ceiling construction as shown in figures 17 through 19 Joist Profiles Rei...

Page 12: ...ury to persons Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service discon...

Page 13: ...the fan has been secured properly Tighten into position if necessary Check that the motor is secured in place If not then tighten the motor in place Check that the fan is not damaged If so replace th...

Page 14: ...Power W 18 Voltage Frenquency 120 VAC 60Hz Housing Dimensions 9 x 9 x 5 3 4 22 9 cm x 22 9 cm x 14 6 cm Grille Dimensions 11 13 16 11 7 16 30 cm x 29 1 cm Net Weight Kg 2 83 WIRING DIAGRAM Black Blac...

Page 15: ...ct our customer service team at cs conglomkb com or 1 877 333 0098 8 30 am 5 pm EST Monday Friday Identify the required part s and have the part number s ready A B C D E F G H Part Description Code Qu...

Page 16: ...conglomkb com service available in English and French Monday Friday from 8 30 am 5 pm EST service disponible en anglais et fran ais du lundi au vendredi 8h30 17h H N E servicio disponible en ingl s y...

Reviews: