background image

R-30 ME .IOM.ENG01

 

 

 

 

 

 

 

 

 
 
 
 
 
 

R-30 ME 

 
Electrically Controlled ON/OFF Valve 

3 Way 

The following is a step by step narrated description of the Eliptix R-

30

ME 

3

W Electrically Controlled 

ON/OFF Valve installation, operation and maintenance processes. 
 The A.R.I. R-

30

 Series is a line of metal, diaphragm-operated, hydraulic control valves. 

The  valves  are  suitable for  installation  in  agriculture, water  transmission  and  waterworks  systems 
for irrigation, landscape and infrastructure applications. 
The R-

30

 series has an innovative elliptic shaped diaphragm that integrates well with a wide variety 

of regulating control pilots, solenoids and control accessories. 
They are compatibility designed for water level control, flow control, electric & remote control as 
well as pressure reducing & pressure sustaining operation. 

 

Summary of Contents for Eliptix R-30ME

Page 1: ...ydraulic control valves The valves are suitable for installation in agriculture water transmission and waterworks systems for irrigation landscape and infrastructure applications The R 30 series has a...

Page 2: ...tial Set up The Pressure Reducing Application 10 3 OPERATION INSTRUCTIONS 11 4 MAINTENANCE 12 4 1 Periodic Inspection 12 4 2 Storing the valve 12 5 TROUBLESHOOTING 13 6 DISMANTLING AND ASSEMBLING THE...

Page 3: ...ever whether caused by accessing and or relying upon this Disclaimer and or in any document enclosed hereto including without limitation any links procedures or materials A R I shall NOT assume any li...

Page 4: ...prior warning Make sure that allproducts outlet portsarenotdirectedtowardelectricalelements pumps orpeople 8 Always open and close valves slowly and gradually 9 Please note that the maximum working pr...

Page 5: ...lations set for handling this type of fluid 3 Before disconnecting the product from the system and before releasing the residual pressure do NOT loosen or unscrew the product bolts removeanyprotection...

Page 6: ...ns 2 Make sure that all the tools ladders lifting devices etc used during the maintenance procedures are taken away from the product area and stored 3 Remove grease and fat material residues in order...

Page 7: ...2 Before installing the valve flush the pipeline to remove scale dirt and other particles that might affect the valve performance 3 Carefully remove the valve from the shipping package Unload all val...

Page 8: ...lve it is recommended to install the following valves Isolation valves upstream and downstream of the control valve 2 2A Air valves upstream and downstream of the control valve 5 3 Close the 3 way sel...

Page 9: ...fittings if necessary 4 For Normally Open Valve Energize the solenoid 4 use the PLC s or the Controller s HMI screen 5 Turn the 3 way selector 3 to its AUTO position 6 For Normally Open Valve De ener...

Page 10: ...ergized water from the valve s upstream port flows into the control chamber and the valve closes When the solenoid is de energized water from the control chamber is released to the atmosphere and the...

Page 11: ...To manually open the valve turn the manual 3 way selector 3 to its OPEN position To manually close the valve turn the manual 3 way selector 3 to its CLOSE 2 To maintain downstream preset pressure open...

Page 12: ...tenance 4 1 Periodic Inspection 1 Every 6 months visually inspect the valve s diaphragm for any tears 2 Every 12 months inspect the valve s operation and clean the Finger Filter 3 Check the downstream...

Page 13: ...the problem continues turn off the water supply to the valve Remove the bonnet and diaphragm remove the foreign object and check that the diaphragm body and cover are not damaged 2 The Diaphragm is d...

Page 14: ...d ring at the other 20 mm spanner open at one end and ring at the other 24 mm spanner open at one end and ring at the other 2 Release Pressure Make sure that the water supply to the valve is switched...

Page 15: ...Disassembling the valve 1 Using a 24mm spanner release the 4 bolts of the valve s bonnet in a diagonal manner A D 2 Un screw the bonnet s bolts E F and remove the bonnet from the valve s body G H 1 1...

Page 16: ...the valve s diaphragm K L 6 4 Cleaning the Finger Filter 1 Disassemble and clean the finger filter using a 20mm spanner release the upstream 2 way manual valve A B Then using a 19mm spanner release th...

Page 17: ...nd tightened in all directions parallel to the valve s body 6 6 Reassembling the Control loop 1 Make sure that all the control loop components are in good condition and clean 2 Clean the control tubin...

Page 18: ...R 30 ME 7 DIMENSIONAL DRAWING...

Page 19: ...R 30 ME 8 SOLENOIDS DATASHEETS...

Page 20: ...R 30 ME...

Page 21: ...le nor does this warranty extended to any consequential or incidental damages or expenses of any kind or nature regardless of the nature thereof including without limitation injury to persons or prope...

Reviews: