Argus CWS100-AV Instruction Manual Download Page 2

MAIN TONE SET 

Tone  

number 

Tone description 

DIP switch 
configuration: 
1,2,3,4 e 5 

Tone designation 

1 * 

800Hz for 500ms, then 1000Hz for 500ms

 

11101

 

Warble Tone

 

2 * 

970Hz continuous tone

 

01011

 

Continuous tone

 

3 * 

500-1200Hz for 3500ms, then off for 500ms

 

10101

 

Slow Whoop (Dutch)

 

4 * 

1200-500Hz swept every 1000ms (1Hz)

 

00111

 

German DIN tone

 

2350-2900Hz swept every 333ms (3Hz)

 

10010

 

Alternate HF slow sweep

 

800Hz for 250ms, then 960Hz for 250ms

 

11110

 

Alternative warble

 

500Hz for 250ms, then 600Hz for 250ms

 

11100

 

Alternative warble

 

500-600Hz swept every 500ms (2Hz)

 

10100

 

Analogue sweep tone

 

970Hz for 625ms, then OFF for 625ms

 

10001

 

Australian Alert (intermittent tone)

 

10 

500-1200Hz sweep for 3750ms, then OFF for 250ms

 

10110

 

Australian Evac (slow whoop)

 

11 

800Hz for 250ms, then 970Hz for 250ms

 

00001

 

FP1063.1-Telecom

 

12 

554Hz for 100ms, then 440Hz for 400ms

 

00101

 

French tone AFNOR

 

13 

2800Hz for 1s, then OFF for 1s

 

11011

 

HF Back up interrupted tone

 

14 

2800Hz for 150ms, then OFF for 150ms

 

11001

 

HF Back up interrupted tone – fast

 

15 

2800Hz continuous

 

01001

 

HF Continuous

 

16 

800Hz for 500ms,then OFF for 500ms

 

01111

 

Interrupted tone

 

17 

1000Hz for 250ms, then OFF for 250ms

 

01101

 

Interrupted tone medium

 

18 

970Hz for 500ms, then OFF for 500ms

 

01110

 

ISO 8201 LF BS5839 Pt 1 1988

 

19 

2850Hz for 500ms, then OFF for 500ms

 

01100

 

ISO 8201 HF

 

20 

800Hz for 150ms, then OFF for 150ms

 

11010

 

LF Back up Alarm

 

21 

800-950Hz swept every 9ms

 

01010

 

LF Buzz

 

22 

800Hz continuous

 

11000

 

LF Continuous tone BS5839

 

23 

No sound

 

11111

 

Silent

 

24 

500-1200Hz rising for 3000ms, then falling for 3000ms

 

00000

 

Siren 2 way ramp (long)

 

25 

500-1200Hz rising for 250ms, then falling for 250ms

 

00010

 

Siren 2 way ramp (short)

 

26 

660Hz continuous

 

00100

 

Swedish all clear signal

 

27 

660Hz for 150ms, then OFF for 150ms

 

00110

 

Swedish Fire signal

 

28 

800-900Hz swept every 1000ms

 

10111

 

Sweep tone (1 Hz)

 

29 

800-970Hz swept every 333ms (3Hz)

 

10011

 

Sweep tone (3 Hz)

 

30 

800-970Hz swept every 111ms (9Hz)

 

01000

 

Sweep tone (9 Hz)

 

31 

(2900Hz for 500ms ON, 500ms OFF) x3, then 1500ms OFF

 

00011

 

US Temporal Pattern HF

 

32 

800-1000Hz swept every 500ms (2Hz) 

10000

 

LF Sweep (Cranford tone) 

Table 3 

ARGUS SECURITY S.R.L.

 - Via del Canneto, 14 - 34015 - Muggia (TS) - Italy 

www.argussecurity.it 

*  EN 54-3 certified tones 

ALTERNATIVE TONE SET 

Tone  

number 

Tone description 

DIP switch configuration: 
1,2,3,4 e 5 

800Hz continuous

 

11101

 

1000Hz continuous tone

 

01011

 

500-1200Hz for 3500ms, then off for 500ms

 

10101

 

800Hz continuous

 

00111

 

2400Hz continuous

 

10010

 

800Hz continuous

 

11110

 

500Hz continuous

 

11100

 

500Hz continuous

 

10100

 

2400Hz continuous

 

10001

 

10 

500-1200Hz sweep for 3750ms, then OFF for 250ms

 

10110

 

11 

500-1200Hz rising for 250ms, then falling for 250ms

 

00001

 

12 

800Hz continuous

 

00101

 

13 

2800Hz continuous

 

11011

 

14 

800Hz continuous

 

11001

 

15 

2800Hz continuous

 

01001

 

16 

800Hz continuous

 

01111

 

17 

800Hz continuous

 

01101

 

18 

970Hz for 500ms, then OFF for 500ms

 

01110

 

19 

2850Hz for 500ms, then OFF for 500ms

 

01100

 

20 

800Hz continuous

 

11010

 

21 

800Hz continuous

 

01010

 

22 

800Hz continuous

 

11000

 

23 

970Hz continuous

 

11111

 

24 

800Hz continuous

 

00000

 

25 

800Hz continuous

 

00010

 

26 

660Hz continuous

 

00100

 

27 

660Hz for 150ms, then OFF for 150ms

 

00110

 

28 

800Hz continuous

 

10111

 

29 

800Hz continuous

 

10011

 

30 

800Hz continuous

 

01000

 

31 

2900Hz continuous

 

00011

 

32 

800Hz continuous

 

10000

 

Table 4 

[email protected] 

L20-CWSVX-0001 (vA.

3

LL 

TESTING 

 
1)  Activate an alarm or evacuate condition at the control panel. 

2)  Check both the audible and visual activation of the sounder/VAD. 

3)  Press the SILENCE SOUNDERS button (or equivalent) and ensure all Sounder type devices have silenced before continuing. 

4)  Reset the system from the control panel. 

All devices must be tested after installation and thereafter on a periodic basis as required by local codes.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

ACOUSTIC OPERATIONAL PERFORMANCE 

ARGUS SECURITY S.R.L.

 - Via del Canneto, 14 - 34015 - Muggia (TS) - Italy 

www.argussecurity.it 

TECHNICAL SPECIFICATIONS * 

Power supply voltage range 

15 - 40 Vdc (24 Vdc standard value) 

Activated current load range, volume set to HIGH. 
Valid for all tones 

11 - 25 mA at 24 Vdc 

Acoustic emission frequency range. 
Valid for all tones 

440 - 2900 Hz 

Maximum acoustic intensity, volume set to HIGH. 
Valid for all tones 

100 dB(A) ± 3 

Visual Alarm Device (VAD) frequency 

0.5 Hz 

VAD flash coverage 

W - 2.5 - 7 (122.5 m

3

Tolerated temperature range 

-10 °C / +55 °C 

Maximum tolerated humidity 

95% RH (without condensation) 

Height (base included) 

192 mm 

Diameter 

130 mm 

Weight (base included) 

290 g 

IP rating (EN 54-3 certified) 

33

 

IP rating (not certified) ** 

65 

*  Consult the latest version of the TDS-CWSXX document for 
further information, obtainable from your supplier. 
 
** Independently assessed and certified to IPX5 (not part of the 
current EN54-3 certification). 

Picture 14 

 

[email protected] 

L20-CWSVX-0001 (vA.

3

LL 

 

WARNINGS AND LIMITATIONS 

 
Our devices use high quality electronic components and plastic materials that are 
highly resistant to environmental deterioration. However, after 10 years of continu-
ous operation, it is advisable to replace the devices in order to minimize the risk of 
reduced performance caused by external factors. Ensure that this device is only 
used with compatible control panels. Detection systems must be checked, ser-
viced and maintained on a regular basis to confirm correct operation. 
Smoke detectors may respond differently to various kinds of smoke particles, thus 
application advice should be sought for special risks. Detectors cannot respond 
correctly if barriers exist between them and the fire location and may be affected 
by special environmental conditions. 
Refer to and follow national codes of practice and other internationally recognized 
fire engineering standards. 
Appropriate risk assessment should be carried out initially to determine correct 
design criteria and updated periodically. 
 

WARRANTY 

 
All devices are supplied with the benefit of a limited 3 year warranty relating to 
faulty materials or manufacturing defects, effective from the production date 
indicated on each product. 
This warranty is invalidated by mechanical or electrical damage caused in the field 
by incorrect handling or usage. 
Product must be returned via your authorized supplier for repair or replacement 
together with full information on any problem identified. 
Full details on our warranty and product’s returns policy can be obtained upon 
request. 

ARGUS SECURITY S.R.L. 

Via del Canneto, 14 

34015 Muggia (TS) 

Italy 

 

15 

 

CO0510CPR  

EN 54-3:2001+A1:2002+A2:2006 

Type B

 
EN 54-23:2010 
 
CWS100-AV 
 
For use in compatible fire detection and alarm system. 
 
Category rating: W - 2.5 - 7 
 
Duration of operation: Pass 
Provision for external conductors: Pass 
Flammability of materials: Pass 
Enclosure protection: Pass 
Access: Pass 
Manufacturer's adjustments: Pass 
On-site adjustment of behaviour: Pass 
Requirements for software controlled devices: Pass 
Coverage volume: Pass 
Variation of light output: Pass 
Minimum and maximum light intensity: Pass 
Light colour: White 
Light temporal pattern / frequency of flashing: N/A / 0.5 Hz 
Marking and data: Pass 
Synchronization: Pass 
Durability: Pass 
Temperature resistance: Pass 
Humidity resistance: Pass 
Shock and vibration resistance: Pass 
Corrosion resistance: Pass 
Electrical stability: Pass 

0832 

Picture 15 