PT-9230 Mobile Computer SDK Programming Manual
175
transmitting them to the host.
When this setting is enabled, the imager stores those Code 39 bar codes that start with a space, and does
not immediately transmit the data.
The imager stores the data in the order in which the bar codes are read, deleting the first space from
each.
The imager transmits the appended data when it reads a Code 39 bar code that starts with a character
other than a space.
Note 4:
Code pages define the mapping of character codes to characters.
The Code Page option is available for Code 39, Code 93, and Code 128.
Code Page
Standard
Description
1
CP ISO 646
2 (Default)
ISO 2022
Automatic National Replacement Characters
3
CP Binary
82
ISO 2022 11 Swe
Swedish Replacement Characters
83
ISO 2022 69 Fra
French/Belgium Replacement Characters
81
ISO 2022 25 Fra
French/Belgium Replacement Characters
84
ISO 2022 11 Ger
German Replacement Characters
85
ISO 2022 11 Ita
Italian Replacement Characters
86
ISO 2022 11 Swi
Swiss Replacement Characters
87
ISO 2022 11 UK
British Replacement Characters
88
ISO 2022 11 Dan
Danish Replacement Characters
89
ISO 2022 11 Nor
Norwegian Replacement Characters
90
ISO 2022 11 Spa
Spanish Replacement Characters
Note 5:
When this setting is enabled, the imager looks for a Codabar symbol having a “D” start character,
adjacent to a symbol having a “D” stop character.
In this case the two messages are concatenated into one with the “D” characters omitted.
This selection has no effect on Codabar symbols without Stop/Start D characters.
Note 6:
When this setting is disable, the imager will auto expands the UPC-A code to the 13 digit, EAN-13