Likewise, if a certain type of barcode needs to be
added with a prefix code, all Code 128 codes are
needed before the letter A; there are two ways to
achieve:
1. 0216 0141
2. 0217 A A
If you want to accumulate, use 0218A.
Sleep time setting / button timeout setting
1.
Sleep time setting code: 0310nnn
If XS sleep is required and it is calculated in
hexadecimal (4 for base), then the formula:
x/4=NNN
For example, if it takes 60 seconds to
automatically shut down, the setting code is
0310015.
If it takes 5 minutes to automatically shut
down, the setting code is 0310015.
Sleep time limit: 42 minutes and 47 seconds
2.
Button timeout setting code: 0235nn
If the button timeout is 4S, the setting code is
023540.
3.
Introduction to the character hiding
The hidden suffix character setting code is
0233nn. To hide the suffix 5 characters, the
setting code is 023305.
The hidden prefix setting code is 0234nn. If
023405 is to hide the prefix 5 characters, just
change the value of nn to change the number
of hidden characters.
See Table 1 below for explanation.