background image

13 

 

2.3

 

Connection 

Your scanner can connect to three types of 

devices: your cradle, a Bluetooth adapter or a 

mobile device. 

2.3.1

 

Connecting the Scanner with the 

Cradle

 

Follow these instructions to link the two 

devices: 

1.

 

Connect power to the cradle. The radio 

LED (marked with a light symbol) will 

blink amber and the cradle will beep. 

2.

 

To ensure the cradle is unlinked from any 

other imager, check if the cradle sends an 

inquiry beep or not (see Inquiry Beep 

Control in page 24

th

). 

3.

 

Read the link label on the bottom of the 

cradle with the imager. The imager will 

sound a good read beep and the LED will 

flash amber. 

4.

 

Re-place the imager in the cradle to 

continue the charge. 

Once a scanner is linked to a cradle, they will 

remain linked until specific action is taken to 

unlink them (see Unlinking). They will remain 

linked if the cradle is unplugged, if the battery 

is removed from the imager or if the entire 

charge is used up, and if the imager is taken 

out of range of the cradle. Under normal 

operation, scanning of the link label will only 

be required once in the life of the product. 

 

 

Summary of Contents for AR-3201

Page 1: ...AR 3201 CCD Scanner User Guide http www argox com service argox com Version V1 2 Date July 19 2019 ...

Page 2: ...ons may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorien...

Page 3: ...ipment must not be co located or operating in conjunction with any other antenna or transmitter AR 3201 Scanner Cradle Frequency 2402MHz 2480MHz RF Power EIRP 9 41 dbm Hereby Argox Information Co Ltd declares that the radio equipment type AR 3201 is in compliance with Directive 2014 53 EU 經型式認證合格之低功率射頻電機 非經許可 公司 商號或使用者均不 得擅自變更頻率 加大功率或變更原 設計之特性及功能 低功率射頻電機之使用不得影響飛 航安全及干擾合法通信 經發現有干 擾現象時 應立即停用 並改善至無 干...

Page 4: ...short circuit heat the battery or dispose of in fire Store battery pack in a proper place Do not expose to temperature above 60 140 Use specified charger only Please dispose of the used batteries following the rules or laws issued by the local government Note All brands and trademarks shall belong to their respective owner Note Specification is subject to changes without notice 警告 電池若未妥善處理 可能會導致爆炸...

Page 5: ...iv 警告使用者 這是甲類的資訊產品 在居住的環境中使用時 可 能會造成射頻干擾 在這種情況下 使用者會被要 求採取某些適當的對策 ...

Page 6: ...th the ASCII table 8 2 1 4 Search your scanner 8 2 2 Battery 9 2 2 1 Charge the battery 9 2 2 2 Replacing the battery 9 2 3 Connection 13 2 3 1 Connecting the Scanner with the Cradle 13 2 3 2 Disconnecting the Scanner from the Cradle 14 2 3 3 Connecting to your cradle again 15 2 3 4 Connecting to a Bluetooth adapter 16 2 3 5 Connecting to a mobile device 18 Connecting to an iOS device 18 Connectin...

Page 7: ...nd postamble 43 3 5 3 String groups 45 Example 45 3 5 4 ID name and capitalization 49 3 6 Scanner information 51 3 6 1 Parameters 51 3 6 2 Data Magic settings 52 3 6 3 Firmware version 52 3 7 Reset your scanner 53 3 8 Update firmware 55 3 9 Data Magic 63 Data Magic commands 64 3 9 1 Bar code scanning 67 Data format 67 Bar codes 70 Example 71 Scan Utility 76 Virtual COM 80 4 Bar codes 82 UPC A 82 U...

Page 8: ...st 129 Italian Pharmacode Code 32 131 Code 16K 134 EAN UCC Composite 135 GS1 Databar Omnidirectional 137 GS1 Databar Limited 139 GS1 Databar Expanded 142 5 Troubleshooting 145 5 1 Scanner issues 145 5 2 Bar code issues 145 6 Specifications 147 6 1 Pin Assignments 150 Appendix A Test symbologies 151 Appendix B ASCII table 154 Appendix C Default settings of bar codes 155 Appendix D Data entry bar co...

Page 9: ... ideal scanning solution for business High decoding performance Fast and easy scan for 1D bar codes Water resistant and dust tight With the IP65 rating AR 3201 can be used in various environments without being damaged by water and dust High optical resolution Reading high density bar codes up to 3 mil Distortion processing Even if your bar code is distorted AR 3201 still recognizes it ...

Page 10: ...open the package immediately and inspect for shipping damage If you discover any damage contact the shipping company and file a claim Argox is not responsible for any damage incurred during shipping Save all package materials for the shipping company to inspect Note If any item is missing please contact your local dealer 1 2 Understand your scanner 1 2 1 Scanner Perspective LED Scan Window Trigger...

Page 11: ...3 Bottom 1 2 2 Cradle Perspective Charging Pins LED Charging Port ...

Page 12: ... The table below shows the LED behavior and the status it indicates Status Scanner LED Cradle LED Scanner Connected Flash blue at 1 second intervals Flash blue at 1 second intervals Scanner Disconnected Off Off Good Scan Flash green once Flash green once Cradle ACK Timeout Flash red every 0 5 second until timeout N A Reset Paging Button Long time press Reset Short time press Paging Cradle Barcode ...

Page 13: ...to status lights your scanner and your cradle make sounds to indicate the status it is in Status Scanner Sound Cradle Sound Scanner Connected Sound 1 N A Scanner Disconnected Sound 2 N A Good Scan A short beep N A Cradle Inquiry N A Beeps five times at 1 second intervals Cradle ACK Timeout Beeps once in low tone A short beep Battery Low Three short beeps fast N A Memory Full Sound 3 N A Programmin...

Page 14: ...6 1 3 3 Vibration Your scanner vibrates in certain status Status Scanner Power On Vibrate Wake up from Sleep Mode Vibrate Good Scan Vibrate ...

Page 15: ...cradle edge 2 Connect the other end of the USB or the RS 232 cable to your computer Note 1 If you ve purchased the USB pack you can charge your scanner by connecting the USB cable to your computer Note 2 If you ve purchased the RS 232 pack connect the power supply to the RS 232 cable and the wall outlet Charging by Full Charge Time Power Supply 4 5 hours USB Cable 6 5 hours 3 Place your scanner on...

Page 16: ... typed or enter characters without a keyboard You can do it by using ASCII codes In Appendix B you ll find the ASCII table Both column and row numbers are hexadecimal The ASCII code of a character is the combination of a column and a row number where the column comes first For example the ASCII code of BEL is 07 and the number sign is 23 You can use the bar codes in Appendix D to scan ASCII codes ...

Page 17: ...urns to green Charging by Full Charge Time Power Supply 4 5 hours USB Cable 6 5 hours Caution Keep the charging pins dry when you put your scanner on your cradle to charge the battery Wet charging pins may cause water seeping into your cradle and shortening its life 2 2 2 Replacing the battery The battery s life is consumed as you use and charge it You need to replace the battery when it wears out...

Page 18: ...to remove the top cover of the scanner directly by hand 4 Please remove the battery cable from the motherboard 5 1 Pull the motherboard up slightly and then 2 pull out the scanner board in the direction of the arrow 1 2 ...

Page 19: ...t Next install a new battery 7 Install the scanner s motherboard back and insert the battery s cable into the projection of the motherboard 8 Please insert the connector of the battery cable into the power jack of the motherboard ...

Page 20: ...nstall back the top cover of the scanner directly by hand 10 Tighten the lower cover of the scanner with 2 screws by using a Phillips screwdriver 11 Install back the rubber band around the scan window of the scanner ...

Page 21: ...ee Inquiry Beep Control in page 24th 3 Read the link label on the bottom of the cradle with the imager The imager will sound a good read beep and the LED will flash amber 4 Re place the imager in the cradle to continue the charge Once a scanner is linked to a cradle they will remain linked until specific action is taken to unlink them see Unlinking They will remain linked if the cradle is unplugge...

Page 22: ...he imager will unlink but the cradle will remain linked to the imager and will not allow another imager to be linked to it In this case you may perform the item 2 below to link another imager 2 Scan the Link Label on an alternate cradle Scanning the link label on a cradle will drop the link between the original pair and establish a link between the imager and new cradle If the new link is performe...

Page 23: ...to other imagers The scanner will not drop its link with the cradle automatically but can be linked to any other cradle by reading its link label Note If just push the button with a short time less than one second a Paging feature will be performed to page the imager which was linked with the cradle 2 3 3 Connecting to your cradle again If your scanner has connected to other device and you want it...

Page 24: ...our scanner to your computer without a cradle To connect your scanner to a Bluetooth adapter 1 Scan the PC Android bar code 2 Double click the Bluetooth icon in the notification area Note Your computer needs to be Bluetooth enabled 3 In the Bluetooth other devices page tap Add Bluetooth or other device ...

Page 25: ...17 4 Tap Bluetooth 5 If it detects your scanner it shows AR3201 XXXXXXXXX X is your scanner s serial number in the list Click your scanner ...

Page 26: ...g to a mobile device AR 3201 is able to connect to an iOS or Android device that you can use to process bar codes Connecting to an iOS device You can connect your scanner to an iOS device such as iPhone iPad or iPod touch The setup screen may vary depending on your device In this section an iPhone is taken for example 1 Scan the iOS HID bar code ...

Page 27: ...t connects successfully the status of your scanner is changed to Connected 4 Tap Notes to open a new note Use your scanner to scan bar codes and the data shows in the note Note Apple iOS devices will allow only one input device working at the same time So when you connect an Argox Cordless Scanner with your Apple device the Apple Virtual Keyboard will be invalid automatically To have the Apple Vir...

Page 28: ...use a smartphone as an example 1 Scan the Android HID bar code 2 On your Android smartphone go to the Bluetooth setting screen Turn on Bluetooth 3 Tap Scan to search Bluetooth devices If it detects your scanner it shows AR3201 XXXXXXXXX X is your scanner s serial number in the list Tap your scanner to connect it 4 When it connects successfully your scanner is shown under Paired devices ...

Page 29: ...se your scanner to scan bar codes and the data shows in the memo 2 3 6 Shipping Mode Setup When the scanner enters shipping mode the scanner will be powered off When being docked to cradle the scanner will back to power Shipping Mode Barcode ...

Page 30: ... setting as a User s default If you reset your scanner to factory default you can still load your setting in this function Save your current setting as default Restore your default setting To customize your scanner you need to scan a series of programming bar codes in the correct order On the last page of this manual you ll see a table of hexadecimal bar codes that can be used with programming bar...

Page 31: ... code 2 In the setting table in the Setting column scan one of the bar codes 3 On the last page scan the bar codes that correspond to the value you want in the Value column When you finish scan the Finish bar code 4 On the lower right corner of the setting table scan the Exit bar code ...

Page 32: ...ing Value using bar codes on the last page Finish Exit Program Setting Option Value Interface selection RS 232 USB HID RS 232 USB HID Auto detection USB Virtual COM 01 03 04 05 Exit Program Setting Exit Value The last page Finish ...

Page 33: ... COM By default your scanner is able to detect the interface automatically When it detects USB it selects HID as your scanner s interface Program Setting Option Value Interface selection RS 232 01 USB HID 03 RS 232 USB HID Auto detection 04 USB Virtual COM 05 Default Exit ...

Page 34: ...01 to 1F For more information about ASCII codes see ASCII table in Appendix B Numeric key The keypad is located to the rightmost of a keyboard You need to select this mode if your program only accepts numerals When selecting Alt Keypad your bar code data will be sent as if you re pressing Alt number It is useful when your bar code contains a special character such as the Euro sign Caps lock It det...

Page 35: ...r barcode data or multi field scanning Program Setting Option Value Keyboard layout USA Belgium Denmark France Germany Italy Portugal Spain Sweden Switzerland UK Latin American Japanese 00 01 02 03 04 05 06 07 08 09 10 11 12 Function key Disable Enable 00 01 Numeric key Alphabetic key Numeric keypad Alt Keypad 00 01 02 ...

Page 36: ...28 Setting Option Value Caps lock Caps lock ON Caps lock OFF 00 01 Inter character delay 00 to 99 ms 00 99 02 Block transmission delay 00 99 10 ms 00 99 10 Default Exit ...

Page 37: ...a timeout you ll hear five warning beeps from it Xon Xoff It is software flow control When your computer is unable to receive data it sends an Xoff signal to notify your scanner to stop sending data it sends an Xon signal when it s ready ACK NAK Your scanner sends data after it received an ACK signal from your computer and will resend data if it receives an NAK signal Inter character delay It dete...

Page 38: ...esponse delay If you use RTS CTS or ACK NAK for flow control you can decide how long your scanner waits your computer to acknowledge the data transmission Program Setting Option Value Flow control None RTS CTS Xon Xoff ACK NAK 00 01 02 03 Inter character delay 00 99 msec 00 99 00 3AC Block delay 00 to 99 00 Response delay 00 99 100 msec 00 99 20 Default Exit ...

Page 39: ...Setting Option Value Baud rate 2400 bps 4800 bps 9600 bps 19200 bps 38400 bps 57600 bps 115200 bps 03 04 05 06 07 08 09 Parity None Odd Even 00 01 02 Data bit 8 bits 7 bits 00 01 Stop bit One bit Two bits 00 01 Default ...

Page 40: ...igger the light bar is turned on If no bar code is decoded after the stand by duration elapsed the light bar is turned off Continue It automatically detects and decodes bar codes in your scanner s field of view You can turn on this mode when you want to decode bar codes without pulling the trigger If no bar code is decoded after the stand by duration elapsed the light bar will flash You can move y...

Page 41: ...decoder needs to confirm a bar code Double read timeout It determines the duration of Double confirm For example if you set 5 times in Double confirm and set 10 milliseconds in Double read timeout the decoder will decode a bar code 5 times in 10 milliseconds You need to turn on Double confirm to use this feature ...

Page 42: ...ood Read Off Momentary Alternate Timeout Off Continue Test only Auto sensing 00 01 02 03 04 05 06 Stand by duration 01 99 second 00 99 06 Double read timeout 01 99 100 msec 01 99 50 Double confirm 00 09 00 no double confirm 00 09 00 Default Exit ...

Page 43: ...r code your scanner will go by the individual setting Inverted image scan When you turn on this feature you can scan both regular and inverted bar codes Position indication When you turn on this feature the light bar keeps flashing This feature determines how long the light bar flashes ISBT Concatenation time out When scanning single ISBT barcode scanner will wait 100ms 200ms or 900ms to output ba...

Page 44: ...9 99 Inverted image scan Disable Enable 00 01 Position indication Disable 30 seconds 60 seconds 90 seconds 120 seconds 150 seconds 180 seconds Continue 00 01 02 03 04 05 06 07 7AO ISBT Concatenation timeout Disable 100ms 200ms 900ms 00 01 02 09 Configuration Auto update Disable Enable 00 03 Default Exit ...

Page 45: ...store data in it Note 1 The scanner will preserve barcode when the wireless is off and will output data right after the scanner is wirelessly connected to the cradle 2 The scanner will preserve barcode when the wireless is off and will output data after the scanner is wirelessly connected to the cradle and its trigger key is pressed 3 For the Force option the scanner will preserve all barcode unti...

Page 46: ...M Handcuff Mode Leash Alarm Disable 10 seconds 30 seconds 60 seconds 00 10 30 60 7AN Data Collection Mode Disable Enable1 Default2 Force3 00 01 02 03 7AJ Deep Sleep Mode Disable 10 minutes 30 minutes 60 minutes 00 01 03 06 Default Exit ...

Page 47: ... good read Beep loudness It is the volume of the good read beep The bigger the number the higher the volume Beep tone freq It is the tone of the good read beep The bigger the number the higher the tone Beep tone duration It is the duration of the good read beep The bigger the number the longer the duration Cradle Inquiry Beep Adjust the cradle inquiry beep time Cradle Beep Loudness Adjust the crad...

Page 48: ...tion Disable Enable LED Enable Vibration Enable both 00 01 02 03 Beeper indication Disable Enable 00 01 Beep loudness 00 07 00 07 07 Beep tone freq 00 99 100 Hz 00 99 40 Beep tone duration 00 99 10 msec 00 99 10 5AJ Cradle Inquiry Beep Disable 10 seconds 30 seconds Continue 00 01 03 08 ...

Page 49: ...41 5AK Cradle Beep Loudness Disable Volume 1 Volume 7 00 01 07 Default Exit ...

Page 50: ... at the end suffix of a bar code You can use up to 22 ASCII characters to customize the prefix and suffix Prefix Name Preamble ID Code Length Barcode Data ID Postamble Suffix Program Setting Option Value Prefix characters setting None 1 22 characters 00 00 ffH ASCII code Suffix characters setting None 1 22 characters 0D 00 ffH ASCII code Default Exit ...

Page 51: ...eamble and postamble can help you to do that Remember you need to turn on preamble postamble transmission to use it Preamble transmission Add a preamble character or characters to a bar code Postamble transmission Add a postamble character or characters to a bar code Prefix Name Preamble ID Code Length Barcode Data ID Postamble Suffix ...

Page 52: ...eamble characters setting None 1 12characters 00 00 ffH ASCII code Postamble characters setting None 1 12haracters 00 00 ffH ASCII code Preamble transmission Disable Enable 00 01 Postamble transmission Disable Enable 00 01 Default Exit ...

Page 53: ...ata Magic Insert data group position It determines the position that the string group will be inserted into Note that the insertion position can t exceed the length of a bar code or the group will be inserted at the end of the bar code The value 00 inserts the group at the beginning of a bar code and 64 inserts the group at the end of a bar code Example To insert a string group into a bar code Ste...

Page 54: ...h bar code This means we re inserting the string into the third position of a bar code 3 Scan the Exit bar code Step 3 Specify the bar code you want to insert 1 We re using Code 128 as an example In the section Code 128 scan the Program and Insert group number selection bar codes 2 On the last page scan 01 and then scan the Finish bar code This means we re inserting Group1 into a Code 128 bar code...

Page 55: ...ASCII code Insert G3 characters setting None 1 12 characters 00 00 ffH ASCII code Insert G4 characters setting None 1 12 characters 00 00 ffH ASCII code Insert G5 characters setting None 1 12 characters 00 00 ffH ASCII code Insert G6 characters setting None 1 12 characters 00 00 ffH ASCII code Insert G7 characters setting None 1 12 characters 00 00 ffH ASCII code ...

Page 56: ... 00 00 ffH ASCII code Insert G10 characters setting None 1 12 characters 00 00 ffH ASCII code Insert data group 1 position 00 63 00 no insertion 00 63 00 Insert data group 2 position 00 63 00 no insertion 00 63 00 Insert data group 3 position 00 63 00 no insertion 00 63 00 Insert data group 4 position 00 63 00 no insertion 00 63 00 Default Exit ...

Page 57: ...ID AIM ID is fixed since it is defined by the AIM organization Code length transmission It shows the length of a bar code at its beginning For example if your bar code is 258963 the result will be 06258963 in which 06 stands for the length of the bar code Code name transmission It shows the name of a bar code type at the beginning of a bar code For example if your bar code type is Code 39 and your...

Page 58: ...ta After code data 00 01 Code ID transmission Disable Proprietary ID AIM ID 00 01 02 Code length transmission Disable Enable 00 01 Code name transmission Disable Enable 00 01 Case conversion Disable Upper case Lower case For bar code data only 00 01 02 Default Exit ...

Page 59: ...ent values of the common properties of all bar codes System parameters It shows the current system settings of your scanner such as interface selection RS 232 indicator transmission and the scan mode String settings It shows all settings of strings such as prefix suffix preamble postamble and string groups Program Setting Bar code settings Unique parameters System parameters String settings Exit ...

Page 60: ... 6 2 Data Magic settings It shows all settings of Data Magic Program Setting Data Magic settings Exit 3 6 3 Firmware version It shows the firmware version of your scanner Program Setting Data Magic settings ...

Page 61: ...n the following bar code to reset your scanner Press and hold the RESET button Press and hold the RESET button until you hear the startup sound Remember the following when resetting your scanner 1 If your scanner is connected to your cradle when you scan the Reset scanner bar code or press the RESET button you reset both of your scanner and cradle 2 If your scanner is not connected to your cradle ...

Page 62: ...reless imager should disconnect with the cradle during shipment All the cordless scanner are suggested to scan the following command before packaging into boxes and ship to customers This command will make the scanner power off and the scanner will be powered on after being placed on the charging cradle ...

Page 63: ...u want to update the firmware of AR 3201 you need to update your cradle s firmware first After that your cradle will reset and try to connect to your scanner Once they establish the connection your cradle will update your scanner s firmware USB connection 1 Start Scan Utility 2 On the File menu click New ...

Page 64: ...he NEW dialog box select AR3201 or AR3201 from the Select Model list and click OK 4 In the Scan Utility dialog box click No 5 On the Tool menu click Download Firmware Download All Scanner or Download All Cradel ...

Page 65: ... upgrade your scanner click OK In the next dialog box click OK Then you need to wait 7 seconds for system to switch your scanner to the DFU mode 7 In the Change Firmware dialog box click Ask to get the current firmware version of your scanner ...

Page 66: ...the firmware file The firmware version in this file needs to be different from the current firmware version of your scanner After loading the file click Download to update the firmware 9 After the update is completed click OK ...

Page 67: ...59 RS 232 connection 1 Start Scan Utility 2 On the File menu click New 3 In the NEW dialog box select AR3201 or AR3201 from the Select Model list and click OK 4 In the Scan Utility dialog box click No ...

Page 68: ...ol menu click Host RS 232 Setup 6 In the Host RS 232 Setup dialog box select the COM port your scanner is using and click Port Setting 7 In the Port Setting dialog box in the Baud rate list select 115200 and click OK ...

Page 69: ...In the Host RS 232 Setup dialog box click OK 9 On the Tool menu click Download Firmware Download All Scanner 10 In the Change Firmware dialog box click Ask to get the current firmware version of your scanner ...

Page 70: ...the firmware file The firmware version in this file needs to be different from the current firmware version of your scanner After loading the file click Download to update the firmware 12 After the update is completed click OK ...

Page 71: ...nt There are two ways to use Data Magic scanning bar codes or using Scan Utility By scanning bar codes you can quickly change the settings without using programs by using Scan Utility you can see the settings at a glance and change them through the easy operated user interface Choose the method that meets your need Important Data Magic default is disabled To enable Data Magic function go to chapte...

Page 72: ...nsert the character String The specified group CutF Definition Remove a character or characters from the left of a text string Attributes From The starting position of the text to be removed To The end position of the text to be removed CutB Definition Remove a character or characters from the right of a text string Attributes From The starting position of the text to be removed To The end positio...

Page 73: ... left Attributes String The specified group Include Remove everything before the specified string Exclude Remove the specified string and everything before it FindB Definition Remove a certain length of the string from the right Attributes String The specified group Include Remove everything before the specified string Exclude Remove the specified string and everything before it Replace Definition...

Page 74: ...places the specific text Erase Definition Remove the specified rule Attributes None Position Range 0 99 Cut Range From 1 99 To 1 99 Note If you use Data Magic by scanning bar codes you don t need the Erase command ...

Page 75: ...and Attribute 1 Attribute 2 Finish Exit Item Description Rule The rule number The lower the number the higher the priority The rule with the high priority will be applied first Command The command you specify in the rule Attribute 1 The attribute varies according to the command Attribute 2 The attribute varies according to the command Command Attribute 1 Attribute 2 InsertF Position String InsertB...

Page 76: ...68 Item Description FindB String Include or Exclude Replace String With String Erase ...

Page 77: ...69 To set an InsertF rule with the sample data scan the following bar codes Program RULE1 InsertF Attr1 Two digits Attr2 Two digits Finish Exit ...

Page 78: ...two digits The first digit 9 indicates Data Magic the second indicates the rule number Data Magic Rules RULE 1 RULE 2 RULE 3 RULE 4 RULE 5 RULE 6 RULE 7 RULE 8 RULE 9 RULE 10 The bar codes below are Data Magic commands Data Magic Commands 0 InsertF 1 CutF 2 CutB 3 Replace ...

Page 79: ...g ARGOX89121121 Group 1 ARGOX Group 2 argox Group 3 GOX Group 4 Tel InsertF Insert Group 4 Attr 2 into the fifth Attr 1 position from the left side of the string Program Rul e Command Attribute 1 Attribute 2 Finis h Exit 1 InsertF 0 5 0 4 Data ARGOX89121121 Result ARGOXTel 89121121 ...

Page 80: ...ta ARGOX89121121 Result ARGOXTel 89121121 CutF Remove first 5 characters from the left of the string Program Rul e Command Attribute 1 Attribute 2 Finis h Exit 3 CutF 0 1 0 5 Data ARGOX89121121 Result 89121121 CutB Remove first 8 characters from the right of the string Program Rul e Command Attribute 1 Attribute 2 Finis h Exit 4 CutB 0 1 0 8 Data ARGOX89121121 Result ARGOX ...

Page 81: ...t Tel 89121121 KeepF Keep the characters from Attr1 to Attr2 from the left of the string Program Rul e Command Attribute 1 Attribute 2 Finis h Exit 6 KeepF 0 3 0 8 Data ARGOX89121121 Result GOX891 KeepB Retain the characters from Attr1 to Attr2 from the right of the string Program Rul e Command Attribute 1 Attribute 2 Finis h Exit 7 KeepB 0 3 0 8 Data ARGOX89121121 Result 891211 ...

Page 82: ...ata ARGOX89121121 Data ARGOX89121121 Result GOX89121121 Result 89121121 FindB Remove Group 3 Attr 1 and everything before it from the right of the string Attribute 2 can be 00 or 01 Program Rul e Command Attribute 1 Attribute 2 Finis h Exit 9 FindB 0 3 0 1 00 Include 01 Exclude Data ARGOX89121121 Data ARGOX89121121 Result ARGOX Result AR Erase Remove the specified rule Program Rule Command Exit Ru...

Page 83: ...l values in Data Magic scan the bar code below Display the current settings To display the current settings of Data Magic scan the following bar codes Program Display Data Magic settings OR Displays Inserted Group settings ...

Page 84: ...the File menu click New 2 In the NEW dialog box select AR3201 or AR3201 from the Select Model list and click OK 3 In the Scan Utility dialog box click No 4 On the Setup menu Click Linear Barcode setup Select which code you want to use then enable Data matrix function click OK 5 On the Setup menu click Scanner Setup and click the Data Magic tab 6 In the Data Magic tab select the Data Magic check bo...

Page 85: ...election type the text you want in the specific box For example if you ve selected Group1 type in the Insert G1 chars setting box The string box accepts up to 12 single byte characters When you re done click OK 10 On the Tool menu click Export Config from Host and click Export If the data is exported successfully you ll hear a long beep In the Data Magic tab you ll find 10 rules Each rule can be s...

Page 86: ...nal String 12345678 Result 15678 CutB From 2 To 4 Original String 12345678 Result 12348 Replace String Group1 With String Group 2 Group 1 456 Group 2 Argox Original String 12345678 Result 123Argox78 KeepF From 2 To 4 Original String 12345678 Result 234 KeepB From 2 To 4 Original String 12345678 Result 567 FindF String Group 3 Group 3 45 Original String 12345678 Include Exclu Include Result 45678 I...

Page 87: ... Group 4 45 Original String 12345678 Include Exclu Include Result 12345 Include Exclu Exclude Result 123 Erase In Rule 10 In the command list click Erase and Rule 10 will be removed You can also clear the Enable check box to remove the rule ...

Page 88: ...erface is set successful you ll hear a long beep and Found New Hardware Wizard will appear on screen 3 In the Found New Hardware Wizard dialog box click Install from a list or specific location Advanced and click Next 4 Click Search for the best driver in these locations and select the Include this location in the search check box Next click Browse and find the driver at your installation path of ...

Page 89: ...ect Model list click AR3201 or AR3201 and click OK 11 On the Tool menu click Host RS 232 Setup 12 In the Host RS 232 Setup dialog box in the RS 232 Setting list click the port you ve seen in step 8 and click Port Setting 13 In the Port Setting dialog box in the Baud rate list click 115200 and click OK Note The installation steps may vary depending on your operating system ...

Page 90: ...left Truncate leading or the right Truncate ending of a bar code Your scanner beeps if the truncate length is longer than the bar code or the parts being truncated by Truncate leading and Truncate ending are overlapped You can truncate up to 15 characters Code ID setting Code ID is an identifier for a bar code It has two modes Proprietary ID or AIM ID If you want to customize the code ID using an ...

Page 91: ...Code ID setting 00 ffH ASCII code 00 ffH A Exit Insertion group number selection It allows you to insert up to two strings into a bar code First you need to set a string in a group and then insert the group into your bar code There are four string groups You can insert the same group two times if you want For more information about how to set a string in a group see Section 3 4 3 String groups ...

Page 92: ... supplemental bar code you can use this feature to decode it The supplemental bar code can be 2 or 5 digits Leading Zero Data Digits 11 Digits Check Digit Supplement digits 2 or 5 or UCC EAN 128 Program Setting Option Value Insert group number selection 00 44 The range of the single digit number 0 4 00 44 00 Supplement digits None 2 digits 5 digits 2 5 digits UCC EAN 128 2 UCC EAN 128 5 UCC EAN 12...

Page 93: ...coder needs to capture the supplemental bar code within the number of times the check counter specified or it determines there s no supplement If you setting 00 it will be failed when you read supplemental bar code Program Setting Option Value Truncation Expansion None Truncate leading zero Expand to EAN13 00 01 02 Supplement check counter 00 99 verification 00 99 5 Exit The ...

Page 94: ...igits Read Turn on or turn off the read function Checksum transmission Append the check digit to the end of a bar code Data Magic Turn on or turn off Data Magic Truncate leading ending See the description in UPC A Code ID setting See the description in UPC A ...

Page 95: ...ssion Disable Enable 00 01 Data Magic Disable Enable 00 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH E Exit Insertion group number selection See the description in UPC A Supplement digits See the description in UPC A ...

Page 96: ...uncate It truncates the leading zeros of a UPC E bar code Expansion It converts a UPC E bar code to the EAN 13 or UPC A format Expansion It extends a UPC E bar code to 13 digit UPC E1 It allows your scanner to decode UPC E bar codes that begin with the number one 1 Supplement check counter See the description in UPC A ...

Page 97: ...digits 5 digits 2 5 digits UCC EAN 128 2 UCC EAN 128 5 UCC EAN 128 All 00 01 02 03 04 05 06 07 Truncation Expansi on None Truncate leading zero Expand to EAN13 Expand to UPCA 00 01 02 03 Expansion Disable Enable 00 01 UPCE 1 Disable Enable 00 01 Supplement check counter 00 99 verification 00 99 05 Exit ...

Page 98: ... check digit to the end of a bar code Data Magic Turn on or turn off Data Magic Truncate leading ending See the description in UPC A Program Setting Option Value Read Disable Enable 00 01 Checksum transmission Disable Enable 00 01 Data Magic Disable Enable 00 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Exit ...

Page 99: ... 5 or UCC EAN 128 ISBN ISSN conversion The ISBN International Standard Book Number and ISSN International Standard Serial Number are bar codes for books and magazines respectively The old ISBN is 10 digit and the old ISSN is 8 digit When you turn on this feature it converts the new ISBN and ISSN to their old format ISBN ID Setting You can set ISBN ID with ASC II code Supplement check counter See t...

Page 100: ...mber selection 00 44 00 44 00 Supplement digits None 2 digits 5 digits 2 5 digits UCC EAN 128 2 UCC EAN 128 5 UCC EAN 128 All 00 01 02 03 04 05 06 07 ISBN ISSN conversion Disable Enable 00 01 ISBN ID setting 00 ffH ASCII code 00 ffH l Supplement check counter 00 99 verification 00 99 05 Exit ...

Page 101: ...ad function Checksum transmission Append the check digit to the end of a bar code Data Magic Turn on or turn off Data Magic Truncate leading ending See the description in UPC A Code ID setting See the description in UPC A Insertion group number selection See the description in UPC A ...

Page 102: ... 01 Checksum transmission Disable Enable 00 01 Data Magic Disable Enable 00 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting Two characters 00 ffH ASCII code 00 ffH 00 ffH FF Insert group number selection 00 44 00 44 00 Exit ...

Page 103: ...its Supplement Digits 2 or 5 or UCC EAN 128 Truncate Expansion Truncate It truncates the leading zeros of an EAN 8 bar code Expansion It converts an EAN 8 bar code to the EAN 13 format Expansion It extends an EAN 8 bar code to 13 digit Supplement check counter See the description in UPC A ...

Page 104: ... digits 5 digits 2 5 digits UCC EAN 128 2 UCC EAN 128 5 UCC EAN 128 All 00 01 02 03 04 05 06 07 Truncation Expansion None Truncate leading zero Expand to EAN13 00 01 02 Expansion Disable Enable 00 01 Supplement check counter 00 99 verifications 00 99 05 Exit ...

Page 105: ...agic Turn on or turn off Data Magic Max Min code length The max and min code length defines the decoding length of a bar code Note the following when you set it length If the code length is shorter than the min or longer than the max the bar code won t be decoded If the min is equal to the max the decoding length is fixed If the max or min is set to zero 00 Global min max code length will take eff...

Page 106: ...ransmit verify Disable Disable Disable Enable Enable Enable 00 01 02 Data Magic Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 01 Truncate leading 0 20 00 20 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Exit ...

Page 107: ...nds all concatenated data to your computer when it decodes a Code 39 bar code that doesn t have a space character at its beginning or when it decodes a bar code that is not Code 39 If your scanner decodes a bar code that has a space character at its beginning it won t send its Code ID Preamble and Prefix if it decodes a bar code that doesn t have a space character it won t send its Code ID and Pre...

Page 108: ...100 Program Setting Option Value Insert group number selection 00 44 00 44 00 Format Standard Full ASCII 00 01 Append Disable Enable 00 01 Start end transmission Disable Enable 00 01 Exit ...

Page 109: ...on Checksum transmit verify See the description in Code 39 Data Magic Turn on or turn off Data Magic Max Min code length See the description in Code 39 Truncate leading ending See the description in UPC A Code ID setting See the description in UPC A Insertion group number selection See the description in UPC A ...

Page 110: ...e Disable Disable Enable Enable Enable 00 01 02 Data Magic Disable Enable 00 01 Max code leading 00 64 00 64 00 Min code leading 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH i Insert group number selection 00 44 00 44 00 ...

Page 111: ...103 Exit ...

Page 112: ...or turn off the read function Data Magic Turn on or turn off Data Magic Max Min code length See the description in Code 39 Truncate leading ending See the description in UPC A Code ID setting See the description in UPC A Insertion group number selection See the description in UPC A ...

Page 113: ...nable 00 01 Data Magic Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH i Insert group number selection 00 44 00 44 00 ...

Page 114: ...Checksum transmit verify See the description in Code 39 Data Magic Turn on or turn off Data Magic Max Min code length See the description in Code 39 Truncate leading ending See the description in UPC A Code ID setting See the description in UPC A Insertion group number selection See the description in UPC A ...

Page 115: ...e Disable Disable Enable Enable Enable 00 01 02 Data Magic Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH B Insert group number selection 00 44 44 00 Exit ...

Page 116: ...t verify See the description in Code 39 Data Magic Turn on or turn off Data Magic Max Min code length See the description in Code 39 Truncate leading ending See the description in UPC A Code ID setting See the description in UPC A Start Data Digits Variable Checksum Optional End ...

Page 117: ...ransmit verifiy Disable Disable Disable Enable Enable Enable 00 01 02 Data Magic Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Exit ...

Page 118: ...acters for the star and stop codes Select one pair to suit your needs Start End transmission See the description in Code 39 Program Setting Option Value Insert group number selection 00 44 00 44 00 Start End type ABCD ABCD abcd abcd ABCD TN E abcd tn e 00 01 02 03 Start End transmission Disable Enable 00 01 Exit ...

Page 119: ...39 Data Magic Turn on or turn off Data Magic Program Setting Option Value Read Disable Enable 00 01 Checksum Transmit Verify Disable Disable Disable Enable Enable Enable 00 01 02 Data Magic Disable Enable 00 01 Exit Max Min code length See the description in Code 39 Truncate leading ending See the description in UPC A Code ID setting See the description in UPC A ...

Page 120: ...d to a field separator which is ASCII code 29 GS C1 Data GS Data Checksum Program Setting Option Value Max code length 00 64 00 64 00 Min code length 00 64 00 64 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Insert group number selection 00 44 00 44 00 Format Standard UCC EAN 128 G S1 128 00 01 Exit ...

Page 121: ...er when it decodes a bar code that doesn t have an FNC2 character at its beginning or when it decodes a bar code that is not Code 128 ISBT enable Enable or disable ISBN barcode readable Field separator code It is used for the bar codes converted to UCC EAN 128 only You can use the ASCII code to customize your field separator The default separator is GS GS1 128 ID See the description in UPC A ...

Page 122: ...tion Value Append Disable Enable Enable Disable Disable Ignore Enable Ignore 00 01 02 03 ISBT enable 00 ffH ASCII code 00 ffH Field separator code 00 ffH ASCII code 00 ffH 1DH GS1 128 ID 00 ffH ASCII code 00 ffH Default Exit ...

Page 123: ... Code 39 Data Magic Turn on or turn off Data Magic Program Setting Option Value Read Disable Enable 00 01 Checksum transmit verify Disable Disable Disable Enable Enable Enable 00 01 02 Data Magic Disable Enable 00 01 Exit Max Min code length See the description in Code 39 Truncate leading ending See the description in UPC A Code ID setting See the description in UPC A ...

Page 124: ...ion in UPC A Program Setting Option Value Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Insert group number selection 00 44 00 44 00 Exit ...

Page 125: ...nction Checksum transmit verify See the description in Code 39 Data Magic Turn on or turn off Data Magic Max Min code length See the description in Code 39 Truncate leading ending See the description in UPC A Code ID setting See the description in UPC A Insertion group number selection See the description in UPC A ...

Page 126: ...t Disable Two digits Enable One digit Enable Two digits 00 01 02 03 04 Data Magic Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH O Insert group number selection 00 44 00 44 00 Exit ...

Page 127: ...ulate the check digit and append it to the bar code The new bar code with the MOD 11 check digit will be calculated again using MOD 10 and then the system appends the MOD 10 check digit to the new bar code The result of the bar code format is DATA MOD 11 check digit MOD 10 check digit Data Magic Turn on or turn off Data Magic Max Min code length See the description in Code 39 Truncate leading endi...

Page 128: ...10 10 N mod 11 10 Y Mod10 Y Mod 10 10 Y Mod 11 10 00 01 02 03 04 05 06 Data Magic Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Insert group number selection 00 44 00 44 00 ...

Page 129: ...121 Exit ...

Page 130: ...wo checksums The first is calculated using modulo 10 and the second is calculated using modulo 11 Data Magic Turn on or turn off Data Magic Max Min code length See the description in Code 39 Truncate leading ending See the description in UPC A Code ID setting See the description in UPC A Insertion group number selection See the description in UPC A ...

Page 131: ... Disable Disable Enable Enable Enable 00 01 02 Data Magic Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Insert group number selection 00 44 00 44 00 Exit ...

Page 132: ...e the description in UK Plessey Data Magic Turn on or turn off Data Magic Max Min code length See the description in Code 39 Truncate leading ending See the description in UPC A Code ID setting See the description in UPC A Insertion group number selection See the description in UPC A ...

Page 133: ...able Enable Enable 00 01 02 Data Magic Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH S Insert group number selection 00 44 00 44 00 Format Numeric only Full ASCII only 00 01 ...

Page 134: ...126 Exit ...

Page 135: ...ksum transmit verify The checksum is calculated using modulo 10 Data Magic Turn on or turn off Data Magic Max Min code length See the description in Code 39 Truncate leading ending See the description in UPC A Code ID setting See the description in UPC A Insertion group number selection See the description in UPC A ...

Page 136: ... Disable Disable Enable Enable Enable 00 01 02 Data Magic Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH i Insert group number selection 00 44 00 44 00 Exit ...

Page 137: ...turn off the read function Data Magic Turn on or turn off Data Magic Max Min code length See the description in Code 39 Truncate leading ending See the description in UPC A Code ID setting See the description in UPC A Insertion group number selection See the description in UPC A ...

Page 138: ... 00 01 Data Magic Disable Enable 00 01 Max code length 00 64 00 64 11 Min code length 00 64 00 64 11 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH t Insert group number selection 00 44 00 44 00 Exit ...

Page 139: ... Data Magic Turn on or turn off Data Magic Max Min code length See the description in Code 39 Truncate leading ending See the description in UPC A Code ID setting See the description in UPC A Insertion group number selection See the description in UPC A Leading A Add the character A at the beginning of a Code 32 bar code ...

Page 140: ...agic Disable Enable 00 01 Max code length 00 64 00 64 12 Min code length 00 64 00 64 09 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 01 ffH p Insert group number selection 00 44 00 44 00 Leading A Disable Enable 00 01 ...

Page 141: ...133 Exit ...

Page 142: ...Code ID setting See the description in UPC A Insertion group number selection See the description in UPC A Program Setting Option Value Read Disable Enable 00 01 Data Magic Disable Enable 00 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Insert group number selection 00 44 00 ffH 00 44 00 Exit ...

Page 143: ...a Magic Turn on or turn off Data Magic Max Min code length See the description in Code 39 Code ID setting See the description in UPC A Insertion group number selection See the description in UPC A UCC EAN 128 emulation See the description in GS1 Databar Omnidirectional ...

Page 144: ...le Enable 00 01 Data Magic Disable Enable 00 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH RC Insert group number selection 00 44 00 44 00 UCC EAN128 emulation Disable Enable 00 01 Exit ...

Page 145: ...Magic Truncate leading ending See the description in UPC A Code ID setting See the description in UPC A Insertion group number selection See the description in UPC A UCC EAN 128 emulation It adds C1 at the beginning of a GS1 bar code You need to turn on AIM ID to use this feature For more information about AIM ID see Section 3 4 4 ID name and capitalization ...

Page 146: ...le Enable 00 01 Data Magic Disable Enable 00 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH R4 Insert group number selection 00 44 00 44 00 UCC EAN128 emulation Disable Enable 00 01 Exit ...

Page 147: ...nal Read Turn on or turn off the read function Data Magic Turn on or turn off Data Magic Code ID setting See the description in UPC A Insertion group number selection See the description in UPC A UCC EAN 128 emulation See the description in GS1 Databar Omnidirectional ...

Page 148: ...a Magic Disable Enable 00 01 UAD Max code length 00 64 00 64 UAE Min code length 00 64 00 64 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH RL Insert group number selection 00 44 00 44 00 Disable Enable 00 01 ...

Page 149: ...141 Setting Option Value UCC EAN128 emulation Exit ...

Page 150: ...off the read function Data Magic Turn on or turn off Data Magic Max Min code length See the description in Code 39 Code ID setting See the description in UPC A Insertion group number selection See the description in UPC A UCC EAN 128 emulation See the description in GS1 Databar Omnidirectional ...

Page 151: ...isable Enable 00 01 Max code length 00 99 00 99 99 Min code length 00 99 00 99 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH RX Insert group number selection 00 44 00 44 00 UCC EAN128 emulation Disable Enable 00 01 ...

Page 152: ...144 Exit ...

Page 153: ...ew battery is charged Your scanner is waiting your computer to acknowledge data and doesn t receive any response Unplug your cradle s cable USB or RS 232 and connect it again Check your USB cable and power supply by connecting them to other compatible devices and test if they work properly If not replace them and charge your scanner again 5 2 Bar code issues My scanner doesn t read the bar code pr...

Page 154: ...r scanner connect to other Bluetooth device Make sure the USB cable is tightly plugged into your cradle and computer Your scanner is connecting to another cradle Break their connection and connect your scanner to your cradle My scanner doesn t decode the bar code but the bar code type is supported Did you turn on Read for the bar code type The density of your bar code may be too high for your scan...

Page 155: ... 700 scans sec Number of Scan 96 000 reads Operation Mode Handcuff mode Deep Sleep mode Data collection mode Auto sensing mode Supported Connection BT 2 1 EDR 100meter Support SPP HID D O F 3mil 60 80mm 4 mil 60 110mm 5mil 50 130mm 10mil 40 310mm 13mil 40 400mm 20mil 45 550mm EAN13 13mil 40 340mm Electrical Battery Rechargeable Li Ion battery pack 3 6 V 2600mAh 9 36 Wh Battery Working Hrs 81 hours...

Page 156: ... Code11 Code39 Code93 Code32 Pharmaceutical Code128 Code bar Interleaved 2 of 5 Industrial 2 of 5 IATA 2 of 5 Matrix 2 of 5 EAN JAN 13 EAN JAN 8 UPC A UPC E UPC A EAN 13 with EXtend Coupon code Telepen Plessey Code GS1 Databar RSS14 GS1 Databar Limited GS1 Databar Omni directional GS1 Databar Expanded China Post Stacked Linear GS1 Databar Expanded Stacked GS1 Databar RSS14 Stacked C16K CodaBlockF ...

Page 157: ... Charge Temperature 0 C to 40 C 32 F to 104 F Humidity 5 to 95 related humidity non condensing Drop Specifications 6 ft 1 8 m drop Contaminants Seals to resist airborne particulate contaminants IP65 Light level 0 80 000 lux REGULATORY EMI RFI CE FCC BSMI NCC ...

Page 158: ... 16 pin 16pin Mini usb Connector Pin RS 232 USB 1 VCC 5V VCC 5V 2 VCC 5V VCC 5V 3 VCC 5V VCC 5V 4 NC NC 5 NA VBUS 6 NA USB_D 7 NA USB_D 8 GND GND 9 GND GND 10 GND GND 11 CTS NA 12 RTS NA 13 RXD NA 14 TXD NA 15 NC NC 16 NC NC ...

Page 159: ...151 Appendix A Test symbologies Bar codes marked with asterisk are turned on initially CODABAR CODE 11 CODE 128 CODE 39 CODE 93 EAN 13 ...

Page 160: ...152 STANDARD 2 of 5 CODE 16K 87549 EAN 8 INDUSTRIAL 2 of 5 UPC E INTERLEAVED 2 of 5 ...

Page 161: ...153 MATRIX 2 of 5 MSI PLESSEY UPC A UK PLESSEY GS1 ...

Page 162: ...6 PgDn F6 ACK SYN 7 F7 BEL ETB 8 Bs F8 BS CAN 9 Tab F9 HT EM A F10 LF SUB B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Insert Ctrl SO RS F Delete Alt SI US L H 2 3 4 5 6 7 0 SP 0 P p 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n F O _ o DEL ...

Page 163: ... E EAN 13 V V V F EAN 8 V V V FF Code 39 V Interleaved 2 of 5 V i Industrial 2 of 5 i Matrix 2 of 5 B Codabar Code 128 V V Code 93 V two digits Code 11 V One digit O MSI Plessey V UK Plessey V Telepen S Standard 2 of 5 i China Post t Italian Pharmacode p Code 16K EAN UCC Composite RC GS1 databar Omnidirectio nal R4 GS1 databar Limited RL ...

Page 164: ...156 Code Type Read Checksum Verification Checksum Transmission Code ID GS1 databar Expanded RX ...

Page 165: ...157 Appendix D Data entry bar codes 0 A 1 B 2 C 3 D 4 E 5 F 6 7 9 8 Finish ...

Reviews: