17
Argos Technologies StarFire XT — Operator’s Manual
English
Troubleshooting (FAQ)
Warnings and notes are displayed when StarFire detects an error (e.g. burner head
missing or check gas).
If an error is detected StarFire XT automatically extinguishes the flame. Press the MENU
BUTTON to acknowledge the error message. This will return to the last operating mode.
All possible error messages are shown below with the recommended course of action.
Error Message
Technical Cause
Possible cause and
correction
Flame detect has
not detected a
flame.
The valve is
closed
Gas supply not connected
• Connect a gas supply
• Turn on the gas supply
• Replace CV360 cartridge
(if being used)
Flame detect electrode
broken or dirty
• Visually inspect electrode
• Clean electrode with
alcohol
• Replace burner head if
necessary
Flame was blown out
several times
• Check the gas/air
mixture
• Prevent draft
The burner head
has not been
detected
Burner head not in place
or inserted correctly
• Insert burner head
Contact pin on burner
head is broken or dirty
• Clean the contact pin
Summary of Contents for StarFire XT
Page 2: ...2 Argos Technologies StarFire XT Operator s Manual English...
Page 103: ......