DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are:
Cooling: Indoor air temperature 27°C DB/19°C WB
Outdoor air temperature 35°C DB/24°C WB
Heating: Indoor air temperature 20°C DB
Outdoor air temperature 7°C DB/6°C WB
3
No. of indoor units.
1-unit
Power Source
220 – 240 V ~ 50 Hz
Cooling
Heating
Capacity
kW 2.55 3.15
BTU/h 8,900 11,100
Air circulation (High) m
3
/h 370
Moisture removal (High) Liters/h 1.3—
Voltage rating V 230
Available voltage range V 198 to 264
Running amperes A 4.6 4.3
Power input W 1000 1150
Power factor % 94 97
C.O.P. W/W 2.55 2.7
Compressor locked rotor amperes A 24
Controls / Temperature control
Microprocessor / I.C. thermostat
Control unit
Wireless remote control unit
Timer
1-hour OFF / 12-hour ON or OFF
Fan speeds Indoor / Outdoor 3 and Auto / 1
Airflow direction (Indoor)
Horizontal Manual
Vertical Manual
Air filter
Washable, Anti–Mold
Compressor
Rotary (Hermetic)
Refrigerant / Amount charged at shipment g R407C / 830
Refrigerant control
Capillary tube
Operation sound
Indoor – Hi / Me / Lo dB-A 37/ 32/ 31
Outdoor – Hi dB-A 53
Refrigerant tubing connections
Flare type
Max. allowable tubing length at shipment
m
7.5
Refrigerant tube
Narrow tube
mm (in.)
6.35 (1/4)
diameter
Wide tube
mm (in.)
9.52 (3/8)
Refrigerant tube kit / Accessories
Optional / Hanging wall bracket
Indoor Unit
Outdoor Unit
Unit dimensions Height mm 700 630
Width mm 560 830
Depth mm 200 305
package dimensions Height mm 770 713
Width mm 620 994
Depth mm 265 413
Weight Net kg 18 61.0
Shipping kg 20 66.0
Shipping volume m
3
0.07 0.29
Dimensions & Weight
Features
Electrical Rating
Performance
Indoor Unit AFR509DHL
Outdoor Unit AER518DH