![Argoclima ARGO 235H Technical Data & Service Manual Download Page 21](http://html1.mh-extra.com/html/argoclima/argo-235h/argo-235h_technical-data-and-service-manual_2967808021.webp)
11 Manual Unit Control and LED indicators
The push button switch and the LED indicators on display panel let the user to control the unit
operation without a R/C (Remote Controller). Their operations are provided below.
Push Button Switch :
Use to cycle the operation mode of the A/C unit among COOL, HEAT and
OFF modes, without using the R/C.
Every time this switch is pressed, the next operation mode is selected,
in order:
- Off => Cool mode => Heat mode => Off => … (for heat pump model)
- Off => Cool mode => Off => … (for cooling only model)
- The A/C will start in Auto IFAN speed and Flap mode as the last setting.
The temperature setting is 22°C for cooling and 28°C for heating mode.
WARNING:
the OFF position does not disconnect the power. Use the main power switch to turn off power completely.
Led indicators :
1. Lights up during Timer and sleep operation.
2. Blinks continuously in case of any wiring trouble.
1. Lights up when the Air conditioner is connected to power and
ready to receive the Remote Control command.
2. Blinks continuously in case of any thermistor failure.
1. Lights up in Operation mode ( Note: OFF in standby mode).
2. Blinks for 0,5 sec., to announce that a R/C infrared signal has
been received and stored.
3. Blinks continuously during:
- OCT (outdoor coil temp.) High pressure protection Mode
- Deicing in Heating Mode
4. Blinks continuously in case of FS (Float Switch) trips for high water level.
12 Recovery from Power Failure
OPERATION
LAMP
STANDBY
TIMER LAMP
BUTTON
OPERATION
LAMP
21
Summary of Contents for ARGO 235H
Page 6: ...DIMENSIONAL DATA C All dimensions are in mm 6...
Page 11: ...1 Cool Mode Operation FUNCTION F 11...
Page 12: ...2 Heat Mode Operation 12...
Page 13: ...3 Auto Cool Heat Mode Operation 13...
Page 14: ...4 Dry Mode Operation 14...
Page 16: ...2 Outdoor Coil High Pressure Protection 16...
Page 17: ...7 Protection Operations in Heat Mode 1 Outdoor Coil Deice Protection 17...
Page 18: ...18...
Page 19: ...2 Indoor Coil High Pressure Protection in Heat Mode 19...
Page 20: ...8 Sleep Function 9 Daily Timer Function 10 IFEEL Function 20...
Page 24: ...24...
Page 25: ...Operation lamp is blinking The condensate drain system is obstructed 25...
Page 26: ...26...
Page 27: ...27...
Page 28: ...Unit still does not run Unit still does not run 28...
Page 30: ...RT RT 30...
Page 32: ...32...
Page 33: ...33...
Page 37: ...3 HYDRAULIC CONNECTIONS AND VALVES 37...
Page 38: ...Via Varese 90 21013 Gallarate Va Italy Tel 39 0331 755111 Fax 39 0331 776240 www argoclima it...