Argo NARCISO 12 Service Manual Download Page 4

FUNCTIONS

APPEARANCE

- 3 -

AIR FILTER

KNOB

DRAIN BUCKET

INTANK OF 
MOIST AIR

OUTLET FOR 
DEHUMIDIFIED
DRY AIR

TURNING WHEEL

CONTINUOUS
DRAINAGE HOLE

BUILT-IN
CABLE STORAGE

Humidity control between
50%-60%.

NORMAL

NORMAL

Dehumidifier stop 
removing moisture.

OFF

OFF

When the water tank is full
the full tank lamp will light up,
the dehumidifier will stop 
operating immediately.

BUCKET FULL LAMP

BUCKET FULL LAMP

When the lamp lights up 
which means dehumidifier 
is operating.

RUNNING LAMP

RUNNING LAMP

When operating under low
temperature for a short period,
the dehumidifier will starting
defrost process, the indicating
lamp will light up.

DEFROST LAMP

DEFROST LAMP

Dehumidifier continuously
removing moisture.

CONTINUOUS

CONTINUOUS

Summary of Contents for NARCISO 12

Page 1: ... Widetech reserves the right to change this dehumidifier s casing circuit and parts without notice Important points on service and operating safety with a flow chart for inspection and repair 1 Troubleshooting 2 Appearance and and functions of this unit 3 Technical specifications 4 Refrigerator system and schematic wiring Diagrams 5 ...

Page 2: ...cing any electrical components they should be factory approved units Be sure that any electrical components are properly wired and in place FLOW CHART FOR INSPECTING AND REPAIRING THE UNIT Dehumidifier doesn t work Check if drain bucket water level switch is broken Electricity shutdown Check fuses on main switch Can not dehumidify Humidity switch is broken Check if air filter is clogged Humidity s...

Page 3: ...ter is dirty Repair or replace Clean filter Detect the leakage and fill with refrigerant Normal Move to level place or use blocks Tighten screws Normal it is the sound when the refrigerant is flowing Clean filter Can not dehumidify or the dehumidifcation volume is too low Refrigerant is leaking Low temp and humidity Uneven floor Loud noise and vibration Motor or compressor is loose Sound of flowin...

Page 4: ...en the water tank is full the full tank lamp will light up the dehumidifier will stop operating immediately BUCKET FULL LAMP BUCKET FULL LAMP When the lamp lights up which means dehumidifier is operating RUNNING LAMP RUNNING LAMP When operating under low temperature for a short period the dehumidifier will starting defrost process the indicating lamp will light up DEFROST LAMP DEFROST LAMP Dehumid...

Page 5: ...220 240V 50Hz Capacitor WATER TANK CAPACITY POWER INPUT W UNIT 12 at 30 C 80 RH WIRE SPECIFICATION A MODEL POWER INPUT EVAPORATOR CONDENSER RxSxFPIxW RxSxFPIxW REFRIGERANT CAPILLARY mm Mm Kg COMP O L P F V 260 1 13 41 2 PHP 206 16A 250V H05VV F VDE 3G0 75mm 405W 632H 290D 13 5 35D020 B1 AADM 1 06 233 LS 16D1 01 30 8 450 MRA12279 12095 R 134a g 150 5 2 4 1R8S21FPI x 12 7mm 2R8S19FPI x 25 4mm D2 2 x...

Page 6: ...R COMPRESSOR ASS Y FAN MOTOR SCHEMATIC WIRING DIAGRAM PTC HEATER 5 REFRIGERATOR SYSTEM DIAGRAM AC CORD WHITE BLUE BLUE FUSE T6 3AL 250V BROWN CMP FAN MOTOR CAPACITOR BLACK WHITE HUMIDITY SWITCH SENSOR RUN LAMP FULL LAMP DEFROST LAMP D6951 630 ...