1-2 Major Component Specifications
Controller PCB
(CE)
WSA
Controls
Microprocessor
Control circuit fuse
250 VAC - 3,15 A
Thermistor (coil sensor)
(TH1)
NTC
Resistance
25 °C
10 °C ± 5%
Thermistor (room sensor)
(TH2)
NTC
Resistance
25 °C
10 °C ± 5%
Fan & Fan Motor
(FM)
M01974
Type
Centrifugal blower
Q'ty ……. Dia. and lenght
mm
1…. Ø 170 / L 156
No. Of poles
4
Rpm
Hi/Me/Lo speed
1275/1156/1058 with flexible exhaust tube retracted
Power input (230 V)
W (Hi / Lo)
109/84/80
GRY-WHT: 87,3 ÷ 101
WHT-VLT: 36,2 ÷ 41,6
VLT-YEL: 22,8 ÷ 26,3
YEL-PNK: 22,8 ÷ 26,3
GRY-BRN: 51,9 ÷ 59,6
type
Thermostat
open
°C
150 ± 10
close
°C
Automatic
(C1)
µF
3
VAC
450
Float microswitch
(MS)
CROUZET F83161.3
Contact rating
16(4) A - 250 VAC
up
open
down
close
Compressor
(CM)
Rotary (hermetic)
Model
Nominal input (230 V)
W
Compressor oil
type …. cc
C - R
Ω
C - S
Ω
Data subject to change without notice
Coil resistance ( 20°C)
Coil resistance (25°C )
Ω
Safety devices
Run capacitor
operating temp.
3,30 ± 7%
5PS102EAA (R410A)
830
RB68A or Freol Alpha 68M ….. 350
3,86 ± 7%
4
Summary of Contents for MAGICO 9.2 AMG26MIR
Page 1: ...TECHNICAL DATA SERVICE MANUAL MAGICO 9 2 AMG26MIR 0 8180 469 0 07 2005...
Page 6: ...2 DIMENSIONAL DATA 2 1 Unit Dimensions 6...
Page 8: ...4 REFRIGERANT FLOW DATA 4 1 Refrigerant flow diagram 8...
Page 19: ...Via Varese 90 21013 Gallarate Va Italy Tel 39 0331 755111 Fax 39 0331 776240 www argoclima it...