![Argo Euro-Line AER508SCLA Technical & Service Manual Download Page 18](http://html1.mh-extra.com/html/argo/euro-line-aer508scla/euro-line-aer508scla_technical-and-service-manual_2967511018.webp)
14
Outdoor Unit AER512SCLA
Controller PCB
Part No. POW-CLR128E
Control circuit fuse
250 V 3.15 A
Compressor
Type
Rotary (Hermetic)
Compressor model C-R110H5HB 80235645B-S
Nominal output
W
1,100
Compressor oil ... Amount cc DAPHNE FV68S ... 510
Coil resistance (Ambient temp. 25°C)
Ω
C–R : 1.962
C–S : 5.38
Safety devices
Type
External(OLR A)
External(OLR T)
Overload relay
MRA98596-9201
CS-7C115
Operating temp. Open °C 150±5 115±3
Close
°C
69±11
95±5
Operating amp.(Ambient temp. 25°C)
Trip in 6 to 16 sec. at 21A
—
Run capacitor
µF
25.0
VAC
400
Crank case heater
240 V 20 W
Fan & Fan Motor
Type
Propeller
Q'ty ... Dia.
1 ... ø400
Fan motor model ... Q'ty KR35410M01846 ... 1
No. of poles ... rpm (230 V, High)
6 ... 770
Nominal output
W
20
Coil resistance (Ambient temp. 25°C)
Ω
BLK-WHT : 211-242
WHT-VLT : 244-281
VLT-YEL : 83.5-96.1
BLK-PNK : 41.7-48.0
Safety devices
Type
Internal fuse
Operating temp.
Open
°C
145±2
Close
°C
—
Run capacitor
µF
2.0
VAC 450
Heat Exch. Coil
Coil
Aluminum plate fin / Copper tube
Rows
1
Fin pitch
mm
1.3
Face area
m
2
0.379
External Finish
Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.