TROUBLESHOOTING 
 

 
PROBLEM 
 

 

POTENTIAL CAUSE 

 

SOLUTION 

The dehumidifier is not working. 

It is not possible to adjust the settings. 

The temperature is above 35 ° C or below 7 

°C. 

The internal tank is full. 

The tank is not positioned correctly. 

The power plug is not inserted correctly. 

The air filter is clogged. 

Empty the tank 

Position the tank correctly  

Correctly connect the plug. 

Remove and clean the air filter. 

The noise suddenly increases while 

running 

The compressor has just started. 

There is a power connection problem. 

The unit is placed on an uneven surface. 

The air filter is clogged. 

Position the unit on an even and 

stable surface. 

Remove and clean the air filter. 

Reduced dehumidification effect 

The room temperature is too low. 

The set humidity level is inadequate. 

The filter is full of dust. 

The doors and windows are open. 

If the unit is running with a temperature 

between 5 and 15 °C, the unit will pause for 

automatic defrosting. The compressor will 

pause for short periods. After the defrost, the 

unit will resume normal operation. 

Reduce the humidity level. 

Clean the filter. 

Close any doors and windows. 

Remove objects that obstruct the 

inflow and outflow of air.  

At first, the air might have a musty 

smell 

Due to the temperature difference of the heat 

exchanger, the air might have a strange smell 

at first. 

 

There is water in the tank even when 

using the hose for continuous 

condensation drainage 

Check the drainage connections. 

The drainage hose is not connected properly. 

 

Connect the hose correctly. 

Remove the drainage hose and 

replace it. 

The ON/OFF LED does not turn on 

when the power is connected 

There is no power or the plug is not inserted 

correctly. 

Check the electrical power supply. 

Make sure that the electric circuit 

and plug are not damaged. 

Make sure that the cable is not 

damaged. 

The dehumidifier stops working during 

dehumidifying process.  

Whether the room temperature is too high or 

too low and out of the working scope of the 

dehumidifier.  

The dehumidifier may start 

automatically when the room 

temperature returns to the working 

scope.  

The humidity of the room can’t reduce.   The room area is too big, which is over its 

application scope.  
The door and windows of the room aren’t 

closed.  

The machine unit is operated with a kerosene 

heater which releases steam.    

 

There is water in the tank.  

Since each machine unit has taken operation 

test before leaving the factory, some water 

remains on the evaporator flows to the water 

tank.       

 

The FULL indicator LED is on.  

When the water tank is full, the FULL indicator 

led is on for reminding.        

 

 

 

 

 

 

 

 

 

Summary of Contents for DRY NATURE 11

Page 1: ...ad the instructions carefully before operating or servicing the dehumidifier Observe all the safety instructions failure to observe the instructions may lead to accidents and or damage Keep these inst...

Page 2: ...ate the defrosting process or to clean the appliance in different ways other than those recommended by the manufacturer Should repair be necessary contact your nearest authorized Argoclima Service Cen...

Page 3: ...all not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Ensure that the electricity system is able to deliver the operating current required by...

Page 4: ...ged from the socket Do not move the air conditioner while it is operating first turn the appliance off check for any condensate build up and empty it if necessary To turn the appliance off set the rem...

Page 5: ...wait at least 3 minutes before starting the unit This helps to prevent the compressor from being damaged WARNING In the event of an anomaly switch the appliance off and unplug from the socket Do not d...

Page 6: ...ir outlet flap 3 Wheels 4 Tank 5 Air inlet and anti dust filter 6 Wiring chord 7 Continuous drain hole 8 Continuous drain ho PRE OPERATING CHECKS AND OPERATIONS Make sure the floater and the condensat...

Page 7: ...temperatures lower than 7 C OPERATING PRECAUTIONS The dehumidifier will start working only if the humidity level set is lower than the humidity in the surrounding environment and It will work till rea...

Page 8: ...ngs TURNING THE DEHUMIDIFIER OFF To turn the dehumidifier off press the POWER button This shuts off power to the unit Unplug the appliance if you do not intend to use it for some time HOW TO ELIMINATE...

Page 9: ...ected humidity by 2 compressor will restart 3 HIGH LOW BUTTON Press this button to select the fan velocity high or low 4 TIMER TEMPERATURE DISPLAY In normal operation this display will show the enviro...

Page 10: ...Fill the tank with clean water a small amount of detergent swill the water around in it then it out and rinse it thoroughly CLEANING THE AIR FILTER WARNING Unplug the unit before start cleaning the ai...

Page 11: ...t first the air might have a musty smell Due to the temperature difference of the heat exchanger the air might have a strange smell at first There is water in the tank even when using the hose for con...

Page 12: ...nd of its life cycle We call your attention to the crucial role played by the consumer in the re use recycling and other forms of recovery of such waste The appliance must be scrapped by a sorted wast...

Reviews: