![Argo AUR101CL Technical Data & Service Manual Download Page 5](http://html1.mh-extra.com/html/argo/aur101cl/aur101cl_technical-data-and-service-manual_2967481005.webp)
b) OUTDOOR UNIT (LITTLE BAG)
MODEL
AUR101CL
AUR131CL
AUR101HL
FAN & FAN MOTOR
Propeller
Propeller
Propeller
Number / Diameter
mm
1 / ø 320
1 / ø 380
1 / ø 380
No of pole / rpm (220 V, high)
4 / 1205
6 / 860
6 / 860
Nominal output
W
58
70
70
BLU-BRN: 249 ÷ 287 BLU-BRN: 218 ÷ 251 BLU-BRN: 218 ÷ 251
BLU-BLK: 270 ÷ 311 BLU-BLK: 230 ÷ 265 BLU-BLK: 230 ÷ 265
Safety device
Internal type
Open
°C
150 ± 10
Close
°C
Automatic
µF
2.0
2.5
2.5
VAC
450
450
450
THERMISTOR (COIL SENSOR) TH3
NTC SENSOR
Resistance (at 25 °C)
k
Ω
10 ± 1%
HEAT EXCHANGE COIL
Coil
Aluminium plate fin / Copper tube
Rows
2
2
2
Fin pitch
mm
1.6
1.6
1.6
Face area
m
2
0.227
0.290
0.290
Setting
Run capacitor (C2)
Coil resistance (at 25 °C)
Ω
B
OPERATING RANGE
COOLING MODELS
Temperature
Indoor air intake temperature Outdoor air intake temperature
Maximun
32 °C DB / 23 °C WB
46 °C DB
Minimum
19 °C DB / 14 °C WB
19 °C DB
HEAT PUMP MODELS
Temperature
Indoor air intake temperature Outdoor air intake temperature
Maximun
32 °C DB / 23 °C WB
46 °C DB
Minimum
19 °C DB / 14 °C WB
19 °C DB
Maximun
27 °C DB / 19 °C WB
24 °C DB / 18 °C WB
Minimum
- DB / - WB
-8 °C DB / -9 °C WB
Cooling
Cooling
Heating